EFFECT OF PHOTOVOLTAIC COMBINED HEAT PUMP SYSTEM ON ENERGY PRODUCTION: AN EXPERIMENTAL OPTIMIZATION

被引:0
|
作者
Zengin, Alperen [1 ]
Sevim, Fatih [1 ]
Ozakin, Ahmet Numan [2 ]
Yesildal, Faruk [2 ]
Yesilyurt, Muhammet Kaan [2 ]
机构
[1] Ataturk Univ, Dept Chem Engn, Erzurum, Turkiye
[2] Ataturk Univ, Dept Mech Engn, Erzurum, Turkiye
关键词
photovoltaic; photovoltaic thermal; heat pump; response surface methodology; TAGUCHI METHOD; PVT SYSTEM; PERFORMANCE; NANOFLUID; EFFICIENCY; FINS; ENHANCEMENT; TEMPERATURE; COLLECTORS; PARAMETERS;
D O I
10.1615/HeatTransRes.2024055119
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study addresses the efficiency decline in photovoltaic (PV) systems due to increased cell temperature. The aim is to find solutions to this fundamental problem in electricity generation from solar energy, which is a pressing concern in the field of renewable energy. The electrical efficiency of the PV system reaches its peak at a cell temperature of 25 degrees C, at which it operates with a yield of around 13% under 1000 W/m(2) irradiance. As the cell temperature increased from 25 degrees C to around 34 degrees C, there was a significant and constant decline in electrical efficiency. At steady-state conditions, the electrical efficiency of PV cells was observed to have decreased from approximately 13% to approximately 8% under 1000 W/m(2), which corresponds to a decline around 38%. In order to cool down the PV panel to prevent this decline and to supply heat to the heat pump system, an industrial heat pump system that operates on a closed cycle using R-134a refrigerant was coupled with the PV system as having its evaporator in tight contact with the back of a 100-W PV panel to set up a photovoltaic thermal heat pump system (PV/T-HP). The PV/T-HP system performance was investigated for three levels of three system parameters (irradiance, condenser mass flow rate, and capillary tube length) through the utilization of the response surface method (RSM), seeking to identify the parameter that had the greatest impact on the heat pump's coefficient of performance (COP). The capillary tube length was found to have the greatest impact, yielding highest COP with 2-m tube length. A remarkable decline in electrical efficiency was observed when the cell temperature rose from 25 degrees C to around 34 degrees C, dropping from approximately 13% to about 8%. The highest COP of 2.61 and the highest efficiency of 0.12 were achieved at optimum conditions.
引用
收藏
页码:75 / 92
页数:18
相关论文
共 50 条
  • [1] An energy optimization model for a combined heat and power production energy supply system with a heat pump
    Dragicevic, S.
    Bojic, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A4) : 321 - 328
  • [2] Economy and energy flexibility optimization of the photovoltaic heat pump system with thermal energy storage
    Li, Benjia
    Liu, Zhongbing
    Zheng, Yue
    Xie, Huahui
    Zhang, Ling
    JOURNAL OF ENERGY STORAGE, 2024, 100
  • [3] Experimental study on a hybrid photovoltaic/heat pump system
    Chen, Hongbing
    Riffat, Saffa B.
    Fu, Yu
    APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) : 4132 - 4138
  • [4] Design and optimization for photovoltaic heat pump system integrating thermal energy storage and battery energy storage
    Zhang, Lei
    Feng, Guohui
    Huang, Kailiang
    Bi, Yang
    Chang, Shasha
    Li, Ainong
    ENERGY AND BUILDINGS, 2025, 329
  • [5] Experimental study of photovoltaic solar assisted heat pump system
    Ji, Jie
    Pei, Gang
    Chow, Tin-tai
    Liu, Keliang
    He, Hanfeng
    Lu, Jianping
    Han, Chongwei
    SOLAR ENERGY, 2008, 82 (01) : 43 - 52
  • [6] Optimization of combined drying system with solar energy and heat-pump for wood drying
    Zhang, Biguang
    Gao, Jianmin
    Yi, Songlin
    Xu, Caixia
    Wang, Tianlong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2009, 30 (11): : 1501 - 1505
  • [7] Simulation and optimal configuration of a combined photovoltaic-thermal and heat pump system with a hybrid energy storage
    Xu, Xiaojie
    Ma, Tao
    Feng, Xinyi
    Weng, Shengjie
    Li, Sinan
    Peng, Jinqing
    ENERGY CONVERSION AND MANAGEMENT, 2024, 317
  • [8] Optimization of heat source with combined production of heat and electric energy
    Balate, Jaroslav
    Klapka, Jindrieh
    Simek, Jakub
    Chramcov, Bronislav
    Navratil, Pavel
    ANNALS OF DAAAM FOR 2007 & PROCEEDINGS OF THE 18TH INTERNATIONAL DAAAM SYMPOSIUM: INTELLIGENT MANUFACTURING & AUTOMATION: FOCUS ON CREATIVITY, RESPONSIBILITY, AND ETHICS OF ENGINEERS, 2007, : 51 - 52
  • [9] Energy performance and economics assessments of a photovoltaic-heat pump system
    Al-Falahat, Ala'a M.
    Abu Qadourah, Jenan
    Alrwashdeh, Saad S.
    Khater, Rahaf
    Qatlama, Zaina
    Alddibs, Emad
    Noor, Mohammad
    RESULTS IN ENGINEERING, 2022, 13
  • [10] Capacity matching and operation optimization of solar energy and air source heat pump combined heating system
    Zhu C.
    Sun T.
    Liu Y.
    Zhou Y.
    Chen Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (08): : 215 - 222