EFFECT OF PHOTOVOLTAIC COMBINED HEAT PUMP SYSTEM ON ENERGY PRODUCTION: AN EXPERIMENTAL OPTIMIZATION

被引:0
作者
Zengin, Alperen [1 ]
Sevim, Fatih [1 ]
Ozakin, Ahmet Numan [2 ]
Yesildal, Faruk [2 ]
Yesilyurt, Muhammet Kaan [2 ]
机构
[1] Ataturk Univ, Dept Chem Engn, Erzurum, Turkiye
[2] Ataturk Univ, Dept Mech Engn, Erzurum, Turkiye
关键词
photovoltaic; photovoltaic thermal; heat pump; response surface methodology; PVT SYSTEM; PERFORMANCE; NANOFLUID; FINS; ENHANCEMENT; TEMPERATURE; COLLECTORS; PARAMETERS; EFFICIENCY; CHANNEL;
D O I
10.1615/HeatTransRes.2024055119
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study addresses the efficiency decline in photovoltaic (PV) systems due to increased cell temperature. The aim is to find solutions to this fundamental problem in electricity generation from solar energy, which is a pressing concern in the field of renewable energy. The electrical efficiency of the PV system reaches its peak at a cell temperature of 25 degrees C, at which it operates with a yield of around 13% under 1000 W/m(2) irradiance. As the cell temperature increased from 25 degrees C to around 34 degrees C, there was a significant and constant decline in electrical efficiency. At steady-state conditions, the electrical efficiency of PV cells was observed to have decreased from approximately 13% to approximately 8% under 1000 W/m(2), which corresponds to a decline around 38%. In order to cool down the PV panel to prevent this decline and to supply heat to the heat pump system, an industrial heat pump system that operates on a closed cycle using R-134a refrigerant was coupled with the PV system as having its evaporator in tight contact with the back of a 100-W PV panel to set up a photovoltaic thermal heat pump system (PV/T-HP). The PV/T-HP system performance was investigated for three levels of three system parameters (irradiance, condenser mass flow rate, and capillary tube length) through the utilization of the response surface method (RSM), seeking to identify the parameter that had the greatest impact on the heat pump's coefficient of performance (COP). The capillary tube length was found to have the greatest impact, yielding highest COP with 2-m tube length. A remarkable decline in electrical efficiency was observed when the cell temperature rose from 25 degrees C to around 34 degrees C, dropping from approximately 13% to about 8%. The highest COP of 2.61 and the highest efficiency of 0.12 were achieved at optimum conditions.
引用
收藏
页码:75 / 92
页数:18
相关论文
共 52 条
[1]   AN EXPERIMENTAL INVESTIGATION TO PREDICT OPTIMUM CHARGE OF A HEAT PUMP SYSTEM [J].
Afshari, Faraz ;
Khanlari, Ataollah ;
Tuncer, Azim Dogus ;
Soezen, Adnan .
HEAT TRANSFER RESEARCH, 2023, 54 (05) :1-13
[2]  
Bayrak F., 2022, ERZINCAN U FEN BILIM, V15, P340, DOI DOI 10.18185/ERZIFBED.971321
[3]   EXPERIMENTAL STUDY TO EVALUATE EFFECT OF SOURCE TEMPERATURE ON COP AND COMPRESSOR STATUS IN WATER-TO-AIR HEAT PUMPS [J].
Ceviz, Mehmet Akif ;
Afshari, Faraz ;
Ceylan, Murat ;
Muratcobanoglu, Burak ;
Mandev, Emre ;
Gelen, Gokhan .
HEAT TRANSFER RESEARCH, 2023, 54 (16) :51-66
[4]   Experimental study on a hybrid photovoltaic/heat pump system [J].
Chen, Hongbing ;
Riffat, Saffa B. ;
Fu, Yu .
APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) :4132-4138
[5]  
Cheng LX, 2022, HEAT TRANSF RES, V53, P1, DOI 10.1615/HeatTransRes.2022044585
[6]   Potential use of photovoltaic-integrated solar heat pump system in Hong Kong [J].
Chow, T. T. ;
Fong, K. F. ;
Pei, G. ;
Ji, J. ;
He, M. .
APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) :1066-1072
[7]   A NUMERICAL STUDY AIMED AT FINDING OPTIMAL ARTIFICIAL NEURAL NETWORK MODEL COVERING EXPERIMENTALLY OBTAINED HEAT TRANSFER CHARACTERISTICS OF HYDRONIC UNDERFLOOR RADIANT HEATING SYSTEMS RUNNING VARIOUS NANOFLUIDS [J].
Colak, Andac Batur ;
Karakoyun, Yakup ;
Acikgoz, Ozgen ;
Yumurtaci, Zehra ;
Dalkilic, Ahmet Selim .
HEAT TRANSFER RESEARCH, 2022, 53 (05) :51-71
[8]   DEVELOPING OPTIMAL ARTIFICIAL NEURAL NETWORK (ANN) TO PREDICT THE SPECIFIC HEAT OF WATER-BASED YTTRIUM OXIDE (Y2O3) NANOFLUID ACCORDING TO THE EXPERIMENTAL DATA AND PROPOSING NEW CORRELATION [J].
Colak, Andac Batur .
HEAT TRANSFER RESEARCH, 2020, 51 (17) :1565-1586
[9]   ENHANCING CONVECTIVE HEAT LOSS REDUCTION IN FLAT-PLATE SOLAR COLLECTORS BY OPTIMAL INTEGRATION OF TRANSPARENT PARTITIONS IN THE AIR GAP [J].
Dahmani, Mourad ;
Ferahta, Fatima Zohra .
HEAT TRANSFER RESEARCH, 2024, 55 (15) :1-19
[10]   EXPERIMENTAL DETERMINATION OF THE EFFECT OF FINS OF DIFFERENT CYLINDRICAL GEOMETRIES ON ELECTRICAL AND THERMAL EFFICIENCY IN AN AIR-COOLED PVT SYSTEM [J].
Demir, Musa ;
Omeroglu, Gokhan ;
Ozakin, Ahmet Numan .
HEAT TRANSFER RESEARCH, 2023, 54 (03) :1-16