Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification

被引:1
|
作者
Farzam, Ramin [1 ,2 ]
Azad, Mohammad Hasan [1 ,2 ]
Moghaddam, Hamid Abrishami [3 ]
Forouzanfar, Mohamad [1 ,3 ,4 ]
机构
[1] Ecole Technol Super, Dept Syst Engn, Montreal, PQ, Canada
[2] K N Toosi Univ Technol, Elect Engn Fac, Tehran, Iran
[3] K N Toosi Univ Technol, Dept Biomed Engn, Tehran 1631714191, Iran
[4] Inst Univ Geriatrie Montreal, Ctr Rech, Montreal, PQ H3C 1B4, Canada
关键词
Estimation; Bayes methods; System identification; Mathematical models; Blood pressure; Biomedical monitoring; Monitoring; Beat-to-beat blood pressure measurement; oscillometry; recursive Bayesian estimation; system identification; CARDIOVASCULAR SIGNALS; STATISTICAL-MODEL;
D O I
10.1109/TBME.2024.3465663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Our study aims to advance noninvasive blood pressure (BP) monitoring through the introduction of innovative beat-to-beat oscillometric BP estimation methods. We aim to overcome current device limitations by delivering continuous and accurate BP estimates, utilizing physiologically based mathematical models. Methods: We developed novel beat-to-beat oscillometric BP estimation methods based on physiologically grounded mathematical models of intra-arterial BP and the arterial system effect. Our approach includes a recursive Bayesian method for parameter estimation and a new system identification technique to refine initial parameter estimates. We tested our methods through simulations and real-world experiments involving 10 individuals. Results: Mean errors for systolic and diastolic BP were as low as -1.26 mmHg and 2.03 mmHg, respectively, with standard deviations of errors at 5.95 mmHg and 4.16 mmHg. Furthermore, our methods enabled the estimation of additional cardiovascular parameters such as heart rate, respiration rate, and mean arterial pressure. Conclusion: Our novel beat-to-beat oscillometric BP estimation methods offer a significant advancement in noninvasive BP monitoring technology, addressing the limitations of current devices by providing continuous beat-to-beat BP estimates. Significance: Our approach represents a promising direction for improving the reliability and comprehensiveness of cardiovascular parameter estimation in noninvasive BP monitoring devices, facilitating more effective patient care and monitoring.
引用
收藏
页码:619 / 629
页数:11
相关论文
共 50 条
  • [41] Postpartum Beat-to-Beat Systolic Blood Pressure Variability in Preeclampsia with Severe Features
    van Wingerden, Anne-Sophie
    Katsidoniotaki, Maria
    Haghighi, Noora
    Almonte, Casandra
    Woolcock, Helen
    Valdes, Eduard
    Alian, Aymen S.
    Booker, Whitney A.
    Bello, Natalie
    Marshall, Randolph
    Kougioumtzoglou, Ioannis
    Petersen, Nils
    Miller, Eliza C.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (01) : S611 - S612
  • [42] Beat-to-beat ambulatory blood pressure variability is different from intermittent ambulatory blood pressure variability
    Sloan, RP
    Berg, J
    Bagiella, E
    Chernikhova, D
    Myers, MM
    PSYCHOSOMATIC MEDICINE, 1998, 60 (01): : 109 - 109
  • [43] Beat-to-Beat Continuous Blood Pressure Estimation Using Bidirectional Long Short-Term Memory Network
    Lee, Dongseok
    Kwon, Hyunbin
    Son, Dongyeon
    Eom, Heesang
    Park, Cheolsoo
    Lim, Yonggyu
    Seo, Chulhun
    Park, Kwangsuk
    SENSORS, 2021, 21 (01) : 1 - 15
  • [44] Changes in beat-to-beat blood pressure and pulse rate variability following stroke
    Abiri, Arash
    Chou, En-Fan
    Shen, Weining
    Fisher, Mark J.
    Khine, Michelle
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [45] The beat-to-beat relationship between pulse transit time and systolic blood pressure
    Poon, Carmen C. Y.
    Zhang, Yuan-Ting
    Wong, George
    Poon, Wai Sang
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 357 - +
  • [46] Increased Beat-to-Beat Blood Pressure Variability Is Associated With Impaired Cognitive Function
    Asmuje, Nur Fazidah
    Mat, Sumaiyah
    Goh, Choon Hian
    Myint, Phyo Kyaw
    Tan, Maw Pin
    AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (12) : 998 - 1005
  • [47] Influence of beat-to-beat blood pressure variability on vascular elasticity in hypertensive population
    Xia, Yufa
    Liu, Xin
    Wu, Dan
    Xiong, Huahua
    Ren, Lijie
    Xu, Lin
    Wu, Wanqing
    Zhang, Heye
    SCIENTIFIC REPORTS, 2017, 7
  • [48] An elastic manifold learning approach to beat-to-beat interval estimation with ballistocardiography signals
    Shen, Gang
    Ding, Ruidong
    Yang, Mingqi
    Han, Dan
    Zhang, Biyong
    ADVANCED ENGINEERING INFORMATICS, 2020, 44
  • [49] Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
    Brueser, Christoph
    Stadlthanner, Kurt
    de Waele, Stijn
    Leonhardt, Steffen
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05): : 778 - 786
  • [50] Elucidation of obstructive sleep apnoea related blood pressure surge using a novel continuous beat-to-beat blood pressure monitoring system
    Kwon, Younghoon
    Baruch, Martin
    Stafford, Patrick L.
    Bonner, Heather
    Cho, Yeilim
    Mazimba, Sula
    Logan, Jeongok G.
    Shimbo, Daichi
    Park, Sung-Ha
    Lin, Gen-Min
    Azarbarzin, Ali
    Calhoun, David A.
    Berry, Richard
    Carey, Robert M.
    JOURNAL OF HYPERTENSION, 2022, 40 (03) : 520 - 527