Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification

被引:1
|
作者
Farzam, Ramin [1 ,2 ]
Azad, Mohammad Hasan [1 ,2 ]
Moghaddam, Hamid Abrishami [3 ]
Forouzanfar, Mohamad [1 ,3 ,4 ]
机构
[1] Ecole Technol Super, Dept Syst Engn, Montreal, PQ, Canada
[2] K N Toosi Univ Technol, Elect Engn Fac, Tehran, Iran
[3] K N Toosi Univ Technol, Dept Biomed Engn, Tehran 1631714191, Iran
[4] Inst Univ Geriatrie Montreal, Ctr Rech, Montreal, PQ H3C 1B4, Canada
关键词
Estimation; Bayes methods; System identification; Mathematical models; Blood pressure; Biomedical monitoring; Monitoring; Beat-to-beat blood pressure measurement; oscillometry; recursive Bayesian estimation; system identification; CARDIOVASCULAR SIGNALS; STATISTICAL-MODEL;
D O I
10.1109/TBME.2024.3465663
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Our study aims to advance noninvasive blood pressure (BP) monitoring through the introduction of innovative beat-to-beat oscillometric BP estimation methods. We aim to overcome current device limitations by delivering continuous and accurate BP estimates, utilizing physiologically based mathematical models. Methods: We developed novel beat-to-beat oscillometric BP estimation methods based on physiologically grounded mathematical models of intra-arterial BP and the arterial system effect. Our approach includes a recursive Bayesian method for parameter estimation and a new system identification technique to refine initial parameter estimates. We tested our methods through simulations and real-world experiments involving 10 individuals. Results: Mean errors for systolic and diastolic BP were as low as -1.26 mmHg and 2.03 mmHg, respectively, with standard deviations of errors at 5.95 mmHg and 4.16 mmHg. Furthermore, our methods enabled the estimation of additional cardiovascular parameters such as heart rate, respiration rate, and mean arterial pressure. Conclusion: Our novel beat-to-beat oscillometric BP estimation methods offer a significant advancement in noninvasive BP monitoring technology, addressing the limitations of current devices by providing continuous beat-to-beat BP estimates. Significance: Our approach represents a promising direction for improving the reliability and comprehensiveness of cardiovascular parameter estimation in noninvasive BP monitoring devices, facilitating more effective patient care and monitoring.
引用
收藏
页码:619 / 629
页数:11
相关论文
共 50 条
  • [1] Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation
    Fleischhauer, Vincent
    Feldheiser, Aarne
    Zaunseder, Sebastian
    SENSORS, 2022, 22 (18)
  • [2] Beat-to-beat ambulatory blood pressure estimation based on random forest
    He, Rui
    Huang, Zhi-Pei
    Ji, Lian-Ying
    Wu, Jian-Kang
    Li, Huihui
    Zhang, Zhi-Qiang
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 194 - 198
  • [3] Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals
    Wuerich, Carolin
    Wiede, Christian
    Schiele, Gregor
    2023 IEEE 36TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS, 2023, : 305 - 310
  • [4] A Probabilistic Beat-to-Beat Filtering Model for Continuous and Accurate Blood Pressure Estimation
    Chen, Zehua
    Dees, Bruno Scalzo
    Mandic, Danilo P.
    2020 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2020,
  • [5] Ambulatory and beat-to-beat blood pressure variability: Are they related?
    Sloan, RP
    Shapiro, PA
    Bagiella, E
    McKinley, PS
    Myers, MM
    Brondolo, EN
    Eichler, B
    PSYCHOSOMATIC MEDICINE, 2001, 63 (01): : 172 - 172
  • [6] Baroreflex failure and beat-to-beat blood pressure variation
    Kishi, Takuya
    HYPERTENSION RESEARCH, 2018, 41 (08) : 547 - 552
  • [7] Baroreflex failure and beat-to-beat blood pressure variation
    Takuya Kishi
    Hypertension Research, 2018, 41 : 547 - 552
  • [8] TRACKING-CUFF SYSTEM FOR BEAT-TO-BEAT RECORDING OF BLOOD-PRESSURE
    SHAPIRO, D
    GREENSTADT, L
    LANE, JD
    RUBINSTEIN, E
    PSYCHOPHYSIOLOGY, 1981, 18 (02) : 129 - 136
  • [9] Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring
    Kim, Joshua
    Chou, En-Fan
    Le, Jamie
    Wong, Sabrina
    Chu, Michael
    Khine, Michelle
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (13)
  • [10] Beat-to-Beat Blood Pressure Variability and Cognition in the MIDUS Study
    Sweigert, Joshua
    McKinley, Paula
    Lachman, Margie
    Gruenewald, Tara
    Seeman, Teresa
    Love, Gayle
    Weinstein, Maxine
    McIntyre, Kathleen
    Duong, Jimmy
    Sloan, Richard P.
    PSYCHOSOMATIC MEDICINE, 2017, 79 (04): : A154 - A155