Evaluation of Pelvic MRI-to-CT Deformable Registration for Adaptive MR-Guided Particle Therapy

被引:0
|
作者
Pestana, Rita [1 ,2 ,3 ,4 ]
Seidensaal, Katharina [1 ,2 ,3 ]
Beyer, Cedric [1 ,2 ,3 ]
Debus, Juergen [1 ,2 ,3 ,5 ,6 ,7 ]
Klueter, Sebastian [1 ,2 ,3 ]
Bauer, Julia [1 ,2 ,3 ]
机构
[1] Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Res Oncol NCRO, Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[4] Heidelberg Univ, Heidelberg, Germany
[5] DKFZ, Natl Ctr Tumor Dis NCT, NCT Heidelberg, Heidelberg, Germany
[6] Heidelberg Univ Hosp, Heidelberg, Germany
[7] German Canc Res Ctr DKFZ Heidelberg, Clin Cooperat Unit Radiat Oncol, Heidelberg, Germany
关键词
Adaptive therapy; Particle therapy; Magnetic resonance; Imaging; Deformable image registration; IMAGE REGISTRATION; RADIOTHERAPY; ALGORITHMS;
D O I
10.1016/j.ijpt.2024.100636
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We aim to assess the magnetic resonance imaging (MRI)-to-CT deformable image registration (DIR) quality of our treatment planning system in the pelvic region as the first step of an online MRI-guided particle therapy clinical workflow. Materials and Methods: Using 2 different DIR algorithms, ANAtomically CONstrained Deformation Algorithm (ANACONDA), the DIR algorithm incorporated in RayStation, and Elastix, an open-source registration software, we retrospectively assessed the quality of the deformed CT (dCT) generation in the pelvic region for 5 patients. T1- and T2-weighted daily control MRI acquired prior to treatment delivery were used for the DIR. We compared the contours automatically mapped on the dCT against the manual contours on the MRI (ground truth) by calculating the Dice similarity coefficients and mean distances to the agreement for organs at risk, targets, and outer contour. We assessed the dosimetric impact of the DIR on the clinical treatment plans, comparing the dosevolume histograms and the value of the clinical goals achieved for each dCT. The water equivalent path lengths and dose range 80% (R80%) maps were compared by casting on the beams' eye view. Results: The T1 sequences performed better for the DIR with ANACONDA compared against the T2. ANACONDA's performance agreed with Elastix. The bladder and rectum led to the worst agreement. For the remaining structures analyzed, Dice similarity coefficients above 0.80 were obtained. Maximum median deviations of 7.1 and 2.1 mm were observed for water equivalent path lengths and R80%, respectively, on the PTV. Conclusion: This work shows a good agreement on the DIR quality achieved with ANACONDA for the structures in the beams' path. By comparing the R80% generated with ANACONDA and Elastix, we give a first quantification of the uncertainties to be considered in an online MRI-guided particle therapy workflow for pelvic treatment.
引用
收藏
页数:9
相关论文
共 43 条
  • [31] Evaluation of the performance of deformable image registration between planning CT and CBCT images for the pelvic region: comparison between hybrid and intensity-based DIR
    Takayama, Yoshiki
    Kadoya, Noriyuki
    Yamamoto, Takaya
    Ito, Kengo
    Chiba, Mizuki
    Fujiwara, Kousei
    Miyasaka, Yuya
    Dobashi, Suguru
    Sato, Kiyokazu
    Takeda, Ken
    Jingu, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2017, 58 (04) : 567 - 571
  • [32] A simulation study of MR-guided proton therapy system using iron-yoked superconducting open MRI: a conceptual study
    Fujii, Yusuke
    Ueda, Hideaki
    Takayanagi, Taisuke
    Nishioka, Kentaro
    Mori, Takashi
    Hashimoto, Takayuki
    Aoyama, Hidefumi
    Umegaki, Kikuo
    Matsuura, Taeko
    JOURNAL OF RADIATION RESEARCH, 2024, 65 (06) : 824 - 835
  • [33] Investigation of undersampling and reconstruction algorithm dependence on respiratory correlated 4D-MRI for online MR-guided radiation therapy
    Mickevicius, Nikolai J.
    Paulson, Eric S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08): : 2910 - 2921
  • [34] Evaluation of a deformable image registration algorithm for image-guided thermal ablation of liver tumors on clinically acquired MR-temperature maps
    Ozenne, Valery
    Bour, Pierre
    Faller, Thibaut
    Desclides, Manon
    de Senneville, Baudouin Denis
    Oecal, Osman
    Lentini, Sergio
    Seidensticker, Max
    Dietrich, Olaf
    Quesson, Bruno
    MEDICAL PHYSICS, 2025, 52 (02) : 722 - 736
  • [35] Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria
    Miller, G. Wilson
    Eames, Matthew
    Snell, John
    Aubry, Jean-Francois
    MEDICAL PHYSICS, 2015, 42 (05) : 2223 - 2233
  • [36] Zero TE-based pseudo-CT image conversion in the head and its application in PET/MR attenuation correction and MR-guided radiation therapy planning
    Wiesinger, Florian
    Bylund, Mikael
    Yang, Jaewon
    Kaushik, Sandeep
    Shanbhag, Dattesh
    Ahn, Sangtae
    Jonsson, Joakim H.
    Lundman, Josef A.
    Hope, Thomas
    Nyholm, Tufve
    Larson, Peder
    Cozzini, Cristina
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1440 - 1451
  • [37] Evaluation of cumulative dose distributions from external beam radiation therapy using CT-to-CBCT deformable image registration (DIR) for cervical cancer patients
    Eckrich, Carolyn
    Lee, Brandon
    Wang, Chunhao
    Light, Kim
    Chino, Junzo
    Rodrigues, Anna
    Craciunescu, Oana
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (01):
  • [38] MRI-Guided Online Adaptive Stereotactic Body Radiation Therapy of Liver and Pancreas Tumors on an MR-Linac System
    Stanescu, Teo
    Shessel, Andrea
    Carpino-Rocca, Cathy
    Taylor, Edward
    Semeniuk, Oleksii
    Li, Winnie
    Barry, Aisling
    Lukovic, Jelena
    Dawson, Laura
    Hosni, Ali
    CANCERS, 2022, 14 (03)
  • [39] Feasibility, usability and acceptance of weekly electronic patient-reported outcomes among patients receiving pelvic CT- or online MR-guided radiotherapy - A prospective pilot study
    Moller, P. K.
    Pappot, H.
    Bernchou, U.
    Schytte, T.
    Mortensen, Z. V.
    Brunni, M. F. A.
    Dieperink, K. B.
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 21 : 8 - 15
  • [40] Quantitative evaluation of a cone-beam computed tomography-planning computed tomography deformable image registration method for adaptive radiation therapy
    Lawson, Joshua D.
    Schreibmann, Eduard
    Jani, Ashesh B.
    Fox, Tim
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (04): : 96 - 113