Evaluation of Pelvic MRI-to-CT Deformable Registration for Adaptive MR-Guided Particle Therapy

被引:0
|
作者
Pestana, Rita [1 ,2 ,3 ,4 ]
Seidensaal, Katharina [1 ,2 ,3 ]
Beyer, Cedric [1 ,2 ,3 ]
Debus, Juergen [1 ,2 ,3 ,5 ,6 ,7 ]
Klueter, Sebastian [1 ,2 ,3 ]
Bauer, Julia [1 ,2 ,3 ]
机构
[1] Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Res Oncol NCRO, Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[4] Heidelberg Univ, Heidelberg, Germany
[5] DKFZ, Natl Ctr Tumor Dis NCT, NCT Heidelberg, Heidelberg, Germany
[6] Heidelberg Univ Hosp, Heidelberg, Germany
[7] German Canc Res Ctr DKFZ Heidelberg, Clin Cooperat Unit Radiat Oncol, Heidelberg, Germany
关键词
Adaptive therapy; Particle therapy; Magnetic resonance; Imaging; Deformable image registration; IMAGE REGISTRATION; RADIOTHERAPY; ALGORITHMS;
D O I
10.1016/j.ijpt.2024.100636
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We aim to assess the magnetic resonance imaging (MRI)-to-CT deformable image registration (DIR) quality of our treatment planning system in the pelvic region as the first step of an online MRI-guided particle therapy clinical workflow. Materials and Methods: Using 2 different DIR algorithms, ANAtomically CONstrained Deformation Algorithm (ANACONDA), the DIR algorithm incorporated in RayStation, and Elastix, an open-source registration software, we retrospectively assessed the quality of the deformed CT (dCT) generation in the pelvic region for 5 patients. T1- and T2-weighted daily control MRI acquired prior to treatment delivery were used for the DIR. We compared the contours automatically mapped on the dCT against the manual contours on the MRI (ground truth) by calculating the Dice similarity coefficients and mean distances to the agreement for organs at risk, targets, and outer contour. We assessed the dosimetric impact of the DIR on the clinical treatment plans, comparing the dosevolume histograms and the value of the clinical goals achieved for each dCT. The water equivalent path lengths and dose range 80% (R80%) maps were compared by casting on the beams' eye view. Results: The T1 sequences performed better for the DIR with ANACONDA compared against the T2. ANACONDA's performance agreed with Elastix. The bladder and rectum led to the worst agreement. For the remaining structures analyzed, Dice similarity coefficients above 0.80 were obtained. Maximum median deviations of 7.1 and 2.1 mm were observed for water equivalent path lengths and R80%, respectively, on the PTV. Conclusion: This work shows a good agreement on the DIR quality achieved with ANACONDA for the structures in the beams' path. By comparing the R80% generated with ANACONDA and Elastix, we give a first quantification of the uncertainties to be considered in an online MRI-guided particle therapy workflow for pelvic treatment.
引用
收藏
页数:9
相关论文
共 43 条
  • [21] A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac
    Chen, Xinfeng
    Ahunbay, Ergun
    Paulson, Eric S.
    Chen, Guangpei
    Li, X. Allen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 205 - 212
  • [22] Comparison of MR-guided radiotherapy accumulated doses for central lung tumors with non-adaptive and online adaptive proton therapy
    Rabe, Moritz
    Palacios, Miguel A.
    de Koste, John van Sornsen R.
    Eze, Chukwuka
    Hillbrand, Martin
    Belka, Claus
    Landry, Guillaume
    Senan, Suresh
    Kurz, Christopher
    MEDICAL PHYSICS, 2023, 50 (05) : 2625 - 2636
  • [23] GAN for synthesizing CT from T2-weighted MRI data towards MR-guided radiation treatment
    Ranjan, Amit
    Lalwani, Debanshu
    Misra, Rajiv
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (03) : 449 - 457
  • [24] An essentially radiation-transparent body coil integrated with a patient rotation system for MR-guided particle therapy
    Dietrich, Kilian A.
    Klueter, Sebastian
    Dinkel, Fabian
    Echner, Gernot
    Brons, Stephan
    Orzada, Stephan
    Debus, Juergen
    Ladd, Mark E.
    Platt, Tanja
    MEDICAL PHYSICS, 2024, 51 (06) : 4028 - 4043
  • [25] Deformable registration using edge-preserving scale space for adaptive image-guided radiation therapy
    Li, Dengwang
    Wang, Hongjun
    Yin, Yong
    Wang, Xiuying
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 105 - 123
  • [26] Simultaneous treatment of two lung cancer lesions with stereotactic MR-guided adaptive radiation therapy: A case report
    Chen, Frank
    Cheng, Yuan-Kai
    Chiang, Chen-Han
    Lu, Tzu-Ying
    Huang, Chih-Jen
    MEDICINE, 2023, 102 (02) : E32626
  • [27] Robust inverse-consistent affine CT-MR registration in MRI-assisted and MRI-alone prostate radiation therapy
    Rivest-Henault, David
    Dowson, Nicholas
    Jason, Peter B.
    Fripp, Jurgen
    Dowling, Jason A.
    MEDICAL IMAGE ANALYSIS, 2015, 23 (01) : 56 - 69
  • [28] An MR-only deep learning inference model-based dose estimation algorithm for MR-guided adaptive radiation therapy
    Liu, Zhiqiang
    Men, Kuo
    Hu, Weigang
    Dai, Jianrong
    Fan, Jiawei
    MEDICAL PHYSICS, 2025,
  • [29] Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR-Linac
    Jassar, Hassan
    Tai, An
    Chen, Xinfeng
    Keiper, Timothy D. D.
    Paulson, Eric
    Lathuiliere, Fabienne
    Beriault, Silvain
    Hebert, Francois
    Savard, Laurence
    Cooper, David T. T.
    Cloake, Sneha
    Li, X. Allen
    MEDICAL PHYSICS, 2023, 50 (05) : 3103 - 3116
  • [30] Toward implementation of MR-guided radiation therapy for laryngeal cancer with healthy volunteer imaging and a custom MR-CT larynx phantom
    Huynh, Elizabeth
    Boyle, Sara
    Campbell, Jennifer
    Penney, Jessica
    Mak, Raymond H.
    Schoenfeld, Jonathan D.
    Leeman, Jonathan E.
    Williams, Christopher L.
    MEDICAL PHYSICS, 2022, 49 (03) : 1814 - 1821