Evaluation of Pelvic MRI-to-CT Deformable Registration for Adaptive MR-Guided Particle Therapy

被引:0
|
作者
Pestana, Rita [1 ,2 ,3 ,4 ]
Seidensaal, Katharina [1 ,2 ,3 ]
Beyer, Cedric [1 ,2 ,3 ]
Debus, Juergen [1 ,2 ,3 ,5 ,6 ,7 ]
Klueter, Sebastian [1 ,2 ,3 ]
Bauer, Julia [1 ,2 ,3 ]
机构
[1] Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Res Oncol NCRO, Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[4] Heidelberg Univ, Heidelberg, Germany
[5] DKFZ, Natl Ctr Tumor Dis NCT, NCT Heidelberg, Heidelberg, Germany
[6] Heidelberg Univ Hosp, Heidelberg, Germany
[7] German Canc Res Ctr DKFZ Heidelberg, Clin Cooperat Unit Radiat Oncol, Heidelberg, Germany
关键词
Adaptive therapy; Particle therapy; Magnetic resonance; Imaging; Deformable image registration; IMAGE REGISTRATION; RADIOTHERAPY; ALGORITHMS;
D O I
10.1016/j.ijpt.2024.100636
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We aim to assess the magnetic resonance imaging (MRI)-to-CT deformable image registration (DIR) quality of our treatment planning system in the pelvic region as the first step of an online MRI-guided particle therapy clinical workflow. Materials and Methods: Using 2 different DIR algorithms, ANAtomically CONstrained Deformation Algorithm (ANACONDA), the DIR algorithm incorporated in RayStation, and Elastix, an open-source registration software, we retrospectively assessed the quality of the deformed CT (dCT) generation in the pelvic region for 5 patients. T1- and T2-weighted daily control MRI acquired prior to treatment delivery were used for the DIR. We compared the contours automatically mapped on the dCT against the manual contours on the MRI (ground truth) by calculating the Dice similarity coefficients and mean distances to the agreement for organs at risk, targets, and outer contour. We assessed the dosimetric impact of the DIR on the clinical treatment plans, comparing the dosevolume histograms and the value of the clinical goals achieved for each dCT. The water equivalent path lengths and dose range 80% (R80%) maps were compared by casting on the beams' eye view. Results: The T1 sequences performed better for the DIR with ANACONDA compared against the T2. ANACONDA's performance agreed with Elastix. The bladder and rectum led to the worst agreement. For the remaining structures analyzed, Dice similarity coefficients above 0.80 were obtained. Maximum median deviations of 7.1 and 2.1 mm were observed for water equivalent path lengths and R80%, respectively, on the PTV. Conclusion: This work shows a good agreement on the DIR quality achieved with ANACONDA for the structures in the beams' path. By comparing the R80% generated with ANACONDA and Elastix, we give a first quantification of the uncertainties to be considered in an online MRI-guided particle therapy workflow for pelvic treatment.
引用
收藏
页数:9
相关论文
共 43 条
  • [1] Evaluation and mitigation of deformable image registration uncertainties for MRI-guided adaptive radiotherapy
    Zhong, Hualiang
    Kainz, Kristofer K.
    Paulson, Eric S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [2] Evaluation of performance of pelvic CT-MR deformable image registration using two software programs
    Ishida, Tomoya
    Kadoya, Noriyuki
    Tanabe, Shunpei
    Ohashi, Haruna
    Nemoto, Hikaru
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1076 - 1082
  • [3] An adaptive MR-CT registration method for MRI-guided prostate cancer radiotherapy
    Zhong, Hualiang
    Wen, Ning
    Gordon, James J.
    Elshaikh, Mohamed A.
    Movsas, Benjamin
    Chetty, Indrin J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07): : 2837 - 2851
  • [4] Oncology Scan-Improvements in Dose Calculation, Deformable Registration, and MR-Guided Radiation Delivery
    Klein, Eric E.
    Das, Indra J.
    Dong, Lei
    Rivard, Mark J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03): : 395 - 397
  • [5] Oncology Scan-Improvements in Dose Calculation, Deformable Registration, and MR-Guided Radiation Delivery COMMENTS
    Vargo, John A.
    Flickinger, John C.
    Beriwal, Sushil
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03): : 398 - 399
  • [6] Evaluation of whole-body MR to CT deformable image registration
    Akbarzadeh, A.
    Gutierrez, D.
    Baskin, A.
    Ay, M. R.
    Ahmadian, A.
    Alam, N. Riahi
    Loevblad, K. O.
    Zaidi, H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 238 - 253
  • [7] Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist® (Gd-EOB-DTPA) enhanced MRI
    Kuznetsova, Svetlana
    Grendarova, Petra
    Roy, Soumyajit
    Sinha, Rishi
    Thind, Kundan
    Ploquin, Nicolas
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (12): : 109 - 118
  • [8] Evaluation of a simplified optimizer for MR-guided adaptive RT in case of pancreatic cancer
    Cusumano, Davide
    Boldrini, Luca
    Menna, Sebastiano
    Teodoli, Stefania
    Placidi, Elisa
    Chiloiro, Giuditta
    Placidi, Lorenzo
    Greco, Francesca
    Stimato, Gerardina
    Cellini, Francesco
    Valentini, Vincenzo
    Azario, Luigi
    De Spirito, Marco
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 20 - 30
  • [9] Deformable image registration of CT and truncated cone-beam CT for adaptive radiation therapy
    Zhen, Xin
    Yan, Hao
    Zhou, Linghong
    Jia, Xun
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22): : 7979 - 7993
  • [10] Performance evaluation of MIND demons deformable registration of MR and CT images in spinal interventions
    Reaungamornrat, S.
    De Silva, T.
    Uneri, A.
    Goerres, J.
    Jacobson, M.
    Ketcha, M.
    Vogt, S.
    Kleinszig, G.
    Khanna, A. J.
    Wolinsky, J-P
    Prince, J. L.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23): : 8276 - 8297