A memory-friendly class-incremental learning method for hand gesture recognition using HD-sEMG

被引:0
作者
Bai, Yu [1 ]
Wu, Le [1 ]
Duan, Shengcai [1 ]
Chen, Xun [1 ]
机构
[1] Univ Sci & Technol China, Sch Informat Sci & Technol, Hefei 230027, Peoples R China
来源
MEDICINE IN NOVEL TECHNOLOGY AND DEVICES | 2024年 / 22卷
基金
中国国家自然科学基金;
关键词
Myoelectric pattern recognition; Memory-friendly; Class-incremental learning;
D O I
10.1016/j.medntd.2024.100308
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hand gesture recognition (HGR) plays a vital role in human-computer interaction. The integration of high-density surface electromyography (HD-sEMG) and deep neural networks (DNNs) has significantly improved the robustness and accuracy of HGR systems. These methods are typically effective for a fixed set of trained gestures. However, the need for new gesture classes over time poses a challenge. Introducing new classes to DNNs can lead to a substantial decrease in accuracy for previously learned tasks, a phenomenon known as "catastrophic forgetting," especially when the training data for earlier tasks is not retained and retrained. This issue is exacerbated in embedded devices with limited storage, which struggle to store the large-scale data of HD-sEMG. Classincremental learning (CIL) is an effective method to reduce catastrophic forgetting. However, existing CIL methods for HGR rarely focus on reducing memory load. To address this, we propose a memory-friendly CIL method for HGR using HD-sEMG. Our approach includes a lightweight convolutional neural network, named SeparaNet, for feature representation learning, coupled with a nearest-mean-of-exemplars classifier for classification. We introduce a priority exemplar selection algorithm inspired by the herding effect to maintain a manageable set of exemplars during training. Furthermore, a task-equal-weight exemplar sampling strategy is proposed to effectively reduce memory load while preserving high recognition performance. Experimental results on two datasets demonstrate that our method significantly reduces the number of retained exemplars to only a quarter of that required by other CIL methods, accounting for less than 5 % of the total samples, while still achieving comparable average accuracy.
引用
收藏
页数:9
相关论文
共 25 条
  • [21] Welling Max, 2009, P 26 ANN INT C MACH, P1121
  • [22] Detecting the universal adversarial perturbations on high-density sEMG signals
    Xue, Bo
    Wu, Le
    Liu, Aiping
    Zhang, Xu
    Chen, Xiang
    Chen, Xun
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 149
  • [23] Yan S-H, 2021, Med. Nov. Technol. Devices, V12, DOI [10.1016/j.medntd.2021.100092, DOI 10.1016/J.MEDNTD.2021.100092]
  • [24] Zenke F, 2017, PR MACH LEARN RES, V70
  • [25] Adaptive Calibration of Electrode Array Shifts Enables Robust Myoelectric Control
    Zhang, Xu
    Wu, Le
    Yu, Bin
    Chen, Xiang
    Chen, Xun
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (07) : 1947 - 1957