Examining Tear Film Dynamics Using the Novel Tear Film Imager

被引:0
|
作者
Mangwani-Mordani, Simran [1 ,2 ]
Baeza, Drew [1 ,3 ]
Acuna, Kelly [4 ]
Antman, Gal [5 ,6 ]
Harris, Alon [7 ]
Galor, Anat [1 ,2 ]
机构
[1] Miami Vet Affairs Med Ctr, Dept Ophthalmol, Surg Serv, Miami, FL USA
[2] Univ Miami, Bascom Palmer Eye Inst, Dept Ophthalmol, Miami, FL USA
[3] Nova Southeastern Univ, Dr Kiran C Patel Coll Allopath Med, Ft Lauderdale, FL USA
[4] Georgetown Univ, Sch Med, Washington, DC USA
[5] Tel Aviv Univ, Fac Med, Tel Aviv, Israel
[6] Rabin Med Ctr, Dept Ophthalmol, Petah Tiqwa, Israel
[7] Icahn Sch Med Mt Sinai, New York, NY USA
关键词
aqueous deficiency; evaporative dry eye; mixed dry eye; tear break up; tear film; MEIBOMIAN GLAND DYSFUNCTION; LIPID LAYER THICKNESS; DRY EYE; EPIDEMIOLOGY; STABILITY; SYMPTOMS;
D O I
10.1097/ICO.0000000000003529
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:The purpose of this study was to examine Tear Film Imager (TFI, AdOM, Israel) generated parameters across controls and dry eye (DE) subgroups and examine the changes in TFI parameters with contact lens (CL) placement.Methods:The retrospective study (n = 48) was conducted at the Miami Veterans Hospital. Symptoms were assessed through validated questionnaires and signs of tear function by tear break-up time and Schirmer scores. Participants were grouped as 1) healthy, 2) evaporative, 3) aqueous deficient, and 4) mixed DE based on tear function. Seventeen individuals had a baseline scan and a repeat scan following CL placement. Descriptives were compared across groups and over time.Results:The median age was 27 years, 74% self-identified as White, 45% as male, and 51% as Hispanic. Subjects in the aqueous deficiency category had lower muco-aqueous layer thickness (MALT) (2672 vs. 3084 nm) but higher lipid layer thickness (47.5 vs. 38.3 nm), lipid break-up time (4.4 vs. 2 seconds), and interblink interval (13.9 vs. 5.4 seconds) compared with the evaporative group. Subjects in the evaporative group had the highest MALT values (3084 vs. 2988, 2672, 3053 nm) compared with healthy, aqueous-deficient, and mixed groups. Symptoms were not significantly correlated with TFI parameters. CL placement significantly decreased MALT values (2869 -> 2175 nm, P = 0.001).Conclusions:The TFI provides unique information regarding the dynamic function of the tear film not captured by clinical examination. TFI generated metrics demonstrate a thinner aqueous layer in individuals with aqueous deficiency but highlight a thicker aqueous layer in those with evaporative DE.
引用
收藏
页码:1547 / 1554
页数:8
相关论文
共 50 条
  • [1] Dynamic assessment of the tear film muco-aqueous and lipid layers using a novel tear film imager (TFI)
    Segev, Fani
    Geffen, Noa
    Galor, Anat
    Cohen, Yoel
    Gefen, Raanan
    Belkin, Avner
    Arieli, Yoel
    Epshtein, Shlomi
    Oren, Anat
    Harris, Alon
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (01) : 136 - 141
  • [2] Tear film imager for dynamic mapping of the human tear film
    Cohen, Yoel
    Epshtein, Shlomi
    Harris, Mon
    Gefen, Raanan
    Kagemann, Lawrence
    Arieli, Yoel
    APPLIED OPTICS, 2019, 58 (29) : 7987 - 7995
  • [3] Tear breakup dynamics: A technique for quantifying tear film instability
    Begley, CG
    Himebaugh, N
    Renner, D
    Liu, HX
    Chalmers, R
    Simpson, T
    Varikooty, J
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (01) : 15 - 21
  • [4] Wavefront sensing and the dynamics of tear film
    Koh, Shizuka
    Maeda, Naoyuki
    CORNEA, 2007, 26 (09) : S41 - S45
  • [5] The thickness of the tear film
    King-Smith, PE
    Fink, BA
    Hill, RM
    Koelling, KW
    Tiffany, JM
    CURRENT EYE RESEARCH, 2004, 29 (4-5) : 357 - 368
  • [6] An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers
    Garcia-Marques, Jose Vicente
    Talens-Estarelles, Cristian
    Martinez-Albert, Noelia
    Garcia-Lazaro, Santiago
    Cervino, Alejandro
    CURRENT EYE RESEARCH, 2021, 46 (09) : 1291 - 1298
  • [7] Osmolality and tear film dynamics
    Stahl, Ulrike
    Willcox, Mark
    Stapleton, Fiona
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (01) : 3 - 11
  • [8] Tear Film-Oriented Diagnosis and Tear Film-Oriented Therapy for Dry Eye Based on Tear Film Dynamics
    Yokoi, Norihiko
    Georgiev, Georgi As
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (14) : DES13 - DES22
  • [9] Human meibum and tear film derived cholesteryl and wax esters in meibomian gland dysfunction and tear film structure
    Khanal, Safal
    Bai, Yuqiang
    Ngo, William
    Nichols, Kelly K.
    Wilson, Landon
    Barnes, Stephen
    Nichols, Jason J.
    OCULAR SURFACE, 2022, 23 : 12 - 23
  • [10] In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain OCT and an efficient delay estimator
    Aranha dos Santos, Valentin
    Schmetterer, Leopold
    Groeschl, Martin
    Garhofer, Gerhard
    Werkmeister, Rene M.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697