Comparing the Performance of Scatter Correction Methods in Cardiac SPECT Imaging with Technetium-99m and Thallium-201 Radioisotopes

被引:0
|
作者
Noori-Asl, Mahsa [1 ]
Eghbal, Maryam [1 ]
机构
[1] Univ Mohaghegh Ardabili, Fac Sci, Dept Phys, Ardebil, Iran
关键词
Energy window; image contrast; scatter correction; single-photon emission computed tomography (SPECT); technetium-99m; thallium-201; PHOTOPEAK;
D O I
10.4103/jmp.jmp_40_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to evaluate the performance of dual-energy window (DEW) and triple-energy window (TEW) scatter correction methods in cardiac SPECT imaging with technetium-99m (Tc-99m) and thallium-201 (Tl-201) radioisotopes.Materials and Methods: The SIMIND Monte Carlo program was used to simulate the imaging system and produce the required projections. Two phantoms, including the simple cardiac phantom and the NCAT phantom, were used to evaluate the scatter correction methods. The simulations were repeated 5 times for each phantom and finally, the mean values obtained from these 5 tests were used in the analysis of the results.Results: The obtained results from this study show that in the case of both investigated phantoms, the use of correction methods leads to improve the contrast of the images obtained from Tc-99m and Tl-201 radioisotopes. In the case of the simple cardiac phantom, the use of DEW and TEW correction methods leads to a relative increase in image contrast of about 23.88% and 12.23% for 99mTc radioisotope and about 29.19% and 20.98% for 201Tl radioisotope, respectively. This relative increase in the case of the NCAT phantom is about 22.48% and 19.43% for 99mTc radioisotope and about 27.74% and 24.74% for 201Tl radioisotope, respectively.Conclusion: According to the obtained results, despite the higher contrast of the noncorrected images of 99mTc radioisotope, the relative increase in contrast of the corrected images of 201Tl radioisotope is more than that of 99mTc radioisotope. Furthermore, for both radioisotopes, the relative increase related to the DEW method is higher than the TEW method.
引用
收藏
页码:464 / 472
页数:9
相关论文
共 50 条
  • [41] Correlation of technetium-99m MIBI and thallium-201 retention in solitary cold thyroid nodules with postoperative histopathology
    Tanju Yusuf Erdil
    Kutlan Özker
    Levent Kabasakal
    Bedii Kanmaz
    Kerim Sönmezoglu
    Kayhan Çetin Atasoy
    Halil Turgut Turoglu
    Ilhami Uslu
    Ali Tan Isitman
    Çetin Önsel
    European Journal of Nuclear Medicine, 2000, 27 : 713 - 720
  • [42] Value of combined technetium-99m hydroxy methylene diphosphonate and thallium-201 imaging in detecting bone metastases from thyroid carcinoma
    Alam, MS
    Takeuchi, R
    Kasagi, K
    Misaki, T
    Miyamoto, S
    Iida, Y
    Hidaka, A
    Konishi, J
    THYROID, 1997, 7 (05) : 705 - 712
  • [43] THE PITFALLS OF TECHNETIUM TC-99M/THALLIUM-201 PARATHYROID SCANNING
    VOORMAN, GS
    PETTI, GH
    SCHULZ, E
    CHONKICH, GD
    KIRK, GA
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1988, 114 (09) : 993 - 995
  • [44] COMPARISON OF TECHNETIUM-99M PYROPHOSPHATE AND TECHNETIUM-99M DTPA AEROSOLS FOR SPECT VENTILATION LUNG IMAGING
    ISITMAN, AT
    COLLIER, BD
    PALMER, DW
    TREMBATH, L
    KRASNOW, AZ
    RAO, SA
    HELLMAN, RS
    HOFFMANN, RG
    PECK, DC
    DELLIS, CJ
    JOURNAL OF NUCLEAR MEDICINE, 1988, 29 (11) : 1761 - 1767
  • [45] Thallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging
    Wu, Ming-Che
    Tsai, Cheng-Ting
    Lin, Hui-Chun
    Sun, Fang-Ju
    Lin, Ku-Hung
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2015, 31 (11): : 562 - 567
  • [46] Flow versus uptake comparisons of thallium-201 with technetium-99m perfusion tracers in a canine model of myocardial ischemia
    Meleca, MJ
    McGoron, AJ
    Gerson, MC
    Millard, RW
    Gabel, M
    Biniakiewicz, D
    Roszell, NJ
    Walsh, RA
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (12) : 1847 - 1856
  • [47] Uptake of technetium-99m-tetrofosmin, technetium-99m-MIBI and thallium-201 in tumor cell lines
    Arbab, AS
    Koizumi, K
    Toyama, K
    Araki, T
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (09) : 1551 - 1556
  • [48] Technetium-99m-tetrofosmin, technetium-99m-MIBI and thallium-201 uptake in rat myocardial cells
    Arbab, AS
    Koizumi, K
    Toyama, K
    Arai, T
    Araki, T
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (02) : 266 - 271
  • [49] Attenuation-corrected rest thallium-201 stress technetium 99m sestamibi myocardial SPECT in normals
    Matsunari, I
    Boning, G
    Ziegler, SI
    Kosa, I
    Nekolla, SG
    Ficaro, EP
    Schwaiger, M
    JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (01) : 48 - 55
  • [50] Attenuation-corrected rest thallium-201/stress technetium 99m sestamibi myocardial SPECT in normals
    Ichiro Matsunari
    Guido Böning
    Sibylle I. Ziegler
    Istvan Kosa
    Stephan G. Nekolla
    Edward P. Ficaro
    Markus Schwaiger
    Journal of Nuclear Cardiology, 1998, 5 : 48 - 55