Comparing the Performance of Scatter Correction Methods in Cardiac SPECT Imaging with Technetium-99m and Thallium-201 Radioisotopes

被引:0
|
作者
Noori-Asl, Mahsa [1 ]
Eghbal, Maryam [1 ]
机构
[1] Univ Mohaghegh Ardabili, Fac Sci, Dept Phys, Ardebil, Iran
关键词
Energy window; image contrast; scatter correction; single-photon emission computed tomography (SPECT); technetium-99m; thallium-201; PHOTOPEAK;
D O I
10.4103/jmp.jmp_40_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to evaluate the performance of dual-energy window (DEW) and triple-energy window (TEW) scatter correction methods in cardiac SPECT imaging with technetium-99m (Tc-99m) and thallium-201 (Tl-201) radioisotopes.Materials and Methods: The SIMIND Monte Carlo program was used to simulate the imaging system and produce the required projections. Two phantoms, including the simple cardiac phantom and the NCAT phantom, were used to evaluate the scatter correction methods. The simulations were repeated 5 times for each phantom and finally, the mean values obtained from these 5 tests were used in the analysis of the results.Results: The obtained results from this study show that in the case of both investigated phantoms, the use of correction methods leads to improve the contrast of the images obtained from Tc-99m and Tl-201 radioisotopes. In the case of the simple cardiac phantom, the use of DEW and TEW correction methods leads to a relative increase in image contrast of about 23.88% and 12.23% for 99mTc radioisotope and about 29.19% and 20.98% for 201Tl radioisotope, respectively. This relative increase in the case of the NCAT phantom is about 22.48% and 19.43% for 99mTc radioisotope and about 27.74% and 24.74% for 201Tl radioisotope, respectively.Conclusion: According to the obtained results, despite the higher contrast of the noncorrected images of 99mTc radioisotope, the relative increase in contrast of the corrected images of 201Tl radioisotope is more than that of 99mTc radioisotope. Furthermore, for both radioisotopes, the relative increase related to the DEW method is higher than the TEW method.
引用
收藏
页码:464 / 472
页数:9
相关论文
共 50 条
  • [21] Extraction and retention of technetium-99m Q12, technetium-99m sestamibi, and thallium-201 in isolated rat heart during coronary acidemia
    Anthony J. McGoron
    Myron C. Gerson
    Danuta S. Biniakiewicz
    Nancy J. Roszell
    Lee C. Washburn
    Ronald W. Millard
    European Journal of Nuclear Medicine, 1997, 24 : 1479 - 1486
  • [22] Technetium-99m tetrofosmin imaging in thyroid diseases: Comparison with Tc-99m-pertechnetate, thallium-201 and Tc-99m-methoxyisobutylisonitrile scans
    Klain, M
    Maurea, S
    Cuocolo, A
    Colao, A
    Marzano, L
    Lombardi, G
    Salvatore, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (12): : 1568 - 1574
  • [23] Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands
    Alessandro Giordano
    Paola Marozzi
    Guido Meduri
    Umberto Ficola
    Maria Lucia Calcagni
    Angelo Vaccaro
    Giuseppe Rubini
    Marco Attard
    Maria Li Puma
    Riccardo Ricci
    Salvatore Corsello
    European Journal of Nuclear Medicine, 1999, 26 : 907 - 911
  • [24] Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands
    Giordano, Alessandro
    Marozzi, Paola
    Meduri, Guido
    Ficola, Umberto
    Calcagni, Maria Lucia
    Vaccaro, Angelo
    Rubini, Giuseppe
    Attard, Marco
    Li Puma, Maria
    Ricci, Riccardo
    Corsello, Salvatore
    European Journal of Nuclear Medicine and Molecular Imaging, 1999, 26 (08): : 907 - 911
  • [25] Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands
    Giordano, A
    Marozzi, P
    Meduri, G
    Ficola, U
    Calcagni, ML
    Vaccaro, A
    Rubini, G
    Attard, M
    Puma, ML
    Ricci, R
    Corsello, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (08) : 907 - 911
  • [27] Monitoring response to therapy with thallium-201 and technetium-99m-sestamibi SPECT in nasopharyngeal carcinoma
    Kostakoglu, L
    Uysal, U
    Ozyar, E
    Hayran, M
    Uzal, D
    Demirkazik, FB
    Kars, A
    Atahan, L
    Bekdik, CF
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (07) : 1009 - 1014
  • [28] Technetium-99m pyrophosphate/thallium-201 dual-isotope SPECT imaging predicts reperfusion injury in patients with acute myocardial infarction after reperfusion
    Akutsu, Yasushi
    Kaneko, Kyouichi
    Kodama, Yusuke
    Li, Hui-Ling
    Nishimura, Hideki
    Hamazaki, Yuji
    Suyama, Jumpei
    Shinozuka, Akira
    Gokan, Takehiko
    Kobayashi, Youichi
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (02) : 230 - 236
  • [29] Stress Thallium-201/Rest Technetium-99m Sequential Dual Isotope High-Speed Myocardial Perfusion Imaging
    Berman, Daniel S.
    Kang, Xingping
    Tamarappoo, Balaji
    Wolak, Arik
    Hayes, Sean W.
    Nakazato, Ryo
    Thomson, Louise E. J.
    Kite, Faith
    Cohen, Ishac
    Slomka, Piotr J.
    Einstein, Andrew J.
    Friedman, John D.
    JACC-CARDIOVASCULAR IMAGING, 2009, 2 (03) : 273 - 282
  • [30] Technetium-99m pyrophosphate/thallium-201 dual-isotope SPECT imaging predicts reperfusion injury in patients with acute myocardial infarction after reperfusion
    Yasushi Akutsu
    Kyouichi Kaneko
    Yusuke Kodama
    Hui-Ling Li
    Hideki Nishimura
    Yuji Hamazaki
    Jumpei Suyama
    Akira Shinozuka
    Takehiko Gokan
    Youichi Kobayashi
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 230 - 236