Accuracy of MRI in detecting seminal vesicle invasion in prostate cancer: a systematic review and meta-analysis

被引:0
作者
Li, Thomas [1 ,2 ]
Graham, Petra L. [3 ]
Cao, Brooke [1 ]
Nalavenkata, Sunny [1 ,2 ]
Patel, Manish I. [1 ,2 ]
Kim, Lawrence [1 ,2 ]
机构
[1] Westmead Hosp, Westmead, NSW, Australia
[2] Univ Sydney, Sydney, NSW, Australia
[3] Macquarie Univ, Sydney, NSW, Australia
关键词
diagnostic accuracy; magnetic resonance imaging; prostate cancer; seminal vesicle; Systematic review; CONTRAST-ENHANCED MRI; RADICAL PROSTATECTOMY; EXTRACAPSULAR EXTENSION; RESONANCE; TUMOR; STRATIFICATION; LOCALIZATION; SENSITIVITY; EXPERIENCE; DIAGNOSIS;
D O I
10.1111/bju.16547
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine the diagnostic test accuracy of multiparametric magnetic resonance imaging (mpMRI) in detecting seminal vesicle invasion (SVI). Methods The Medical Literature Analysis and Retrieval System Online (MEDLINE), PubMed, the Excerpta Medica dataBASE (EMBASE) and Cochrane databases were search up to May 2023. We included studies that investigated the accuracy of mpMRI in detecting SVI when compared to radical prostatectomy specimens as the reference standard. Data extraction was performed by two independent reviewers to construct 2 x 2 tables, as well as patient and study characteristics. The methodological quality of the included studies was assessed with the Quality of Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and presented graphically with summary receiver operator characteristic (SROC) plots. Results A total of 27 articles with 4862 patients were included for analysis. The summary sensitivity and specificity were 0.57 (95% confidence interval [CI] 0.45-0.68) and 0.95 (95% CI 0.92-0.99), respectively. Meta-regression indicated that there was no evidence that coil strength (P = 0.079), coil type (P = 0.589), year of publication (P = 0.503) or use of the Prostate Imaging-Reporting and Data System (P = 0.873) significantly influenced these results. The summary diagnostic odds ratio was 28.3 (95% CI 15.0-48.8) and the area under the curve for the SROC curve was 0.87. The I2 statistic was a modest 11.9%. In general, methodological quality was good. Conclusion The use of mpMRI in detecting SVI has excellent specificity but poor sensitivity. Both endorectal coils and magnetic field strength do not significantly impact the accuracy of MRI. These findings suggest that mpMRI cannot reliably rule out SVI in patients with prostate cancer.
引用
收藏
页码:17 / 28
页数:12
相关论文
共 50 条
  • [41] Diagnostic Accuracy of MRI for Detecting Cervical Invasion in Patients with Endometrial Carcinoma: A Meta-Analysis
    Bi, Qiu
    Bi, Guoli
    Wang, Junna
    Zhang, Jie
    Li, Hongliang
    Gong, Xiarong
    Ren, Lixiang
    Wu, Kunhua
    JOURNAL OF CANCER, 2021, 12 (03): : 754 - 764
  • [42] Accuracy of novel urinary biomarker tests in the diagnosis of prostate cancer: A systematic review and network meta-analysis
    Wang, Leibo
    He, Wei
    Shi, Guanyu
    Zhao, Guoqiang
    Cen, Zhuangding
    Xu, Feng
    Tian, Wu
    Zhao, Xin
    Mo, Chishou
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [43] Diagnostic accuracy of multiparametric ultrasound in the diagnosis of prostate cancer: systematic review and meta-analysis
    Tang, Yun
    Li, Xingsheng
    Jiang, Qing
    Zhai, Lingyun
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [44] Biparametric vs multiparametric prostate magnetic resonance imaging for the detection of prostate cancer in treatment-naive patients: a diagnostic test accuracy systematic review and meta-analysis
    Alabousi, Mostafa
    Salameh, Jean-Paul
    Gusenbauer, Kaela
    Samoilov, Lucy
    Jafri, Ali
    Yu, Hang
    Alabousi, Abdullah
    BJU INTERNATIONAL, 2019, 124 (02) : 209 - 220
  • [45] MRI-based radiomics for prediction of biochemical recurrence in prostate cancer: a systematic review and meta-analysis
    Salimi, Mohsen
    Vadipour, Pouria
    Houshi, Shakiba
    Yazdanpanah, Fereshteh
    Seifi, Sharareh
    ABDOMINAL RADIOLOGY, 2025,
  • [46] The Diagnostic Performance of MRI for Detection of Extramural Venous Invasion in Colorectal Cancer: A Systematic Review and Meta-Analysis of the Literature
    Kim, Tae-Hyung
    Woo, Sungmin
    Han, Sangwon
    Suh, Chong Hyun
    Vargas, Hebert Alberto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (03) : 575 - 585
  • [47] Accuracy of artificial intelligence in detecting tumor bone metastases: a systematic review and meta-analysis
    Tao, Huimin
    Hui, Xu
    Zhang, Zhihong
    Zhu, Rongrong
    Wang, Ping
    Zhou, Sheng
    Yang, Kehu
    BMC CANCER, 2025, 25 (01)
  • [48] Diagnostic accuracy of multiparametric ultrasound in the diagnosis of prostate cancer: systematic review and meta-analysis
    Yun Tang
    Xingsheng Li
    Qing Jiang
    Lingyun Zhai
    Insights into Imaging, 14
  • [49] Diagnostic Accuracy of Contrast-Enhanced MRI for Detection of Perineural Spread in Head and Neck Cancer: A Systematic Review and Meta-Analysis
    Sharma, Pranav
    Ajjikuttira, Aiyapa
    Malacova, Eva
    Gillespie, Jennifer
    JOURNAL OF NEUROLOGICAL SURGERY PART B-SKULL BASE, 2024, 85 : e97 - e109
  • [50] MRI Features for Predicting Microvascular Invasion of Hepatocellular Carcinoma: A Systematic Review and Meta-Analysis
    Hong, Seung Baek
    Choi, Sang Hyun
    Kim, So Yeon
    Shim, Ju Hyun
    Lee, Seung Soo
    Byun, Jae Ho
    Park, Seong Ho
    Kim, Kyung Won
    Kim, Suk
    Lee, Nam Kyung
    LIVER CANCER, 2021, 10 (02) : 94 - 106