Identification of volatile biomarkers in exhaled breath by polythiophene solid phase microextraction fiber for disease diagnosis using GC-MS

被引:2
|
作者
Pelit, Fusun [1 ,2 ]
Goksel, Ozlem [2 ,3 ]
Dizdas, Tugberk Nail [1 ,2 ]
Arin, Aycan [1 ,2 ]
Ozgur, Su [2 ]
Erbas, Ilknur [1 ,2 ]
Gursoy, Arif [2 ,4 ]
Ordin, Burak [2 ,4 ]
Karakus, Haydar Soydaner [2 ,3 ]
Ertas, Fatma Nil [1 ,2 ]
Ozdemir, Durmus [5 ]
Goksel, Tuncay [2 ,3 ]
Pelit, Levent [1 ,2 ]
机构
[1] Ege Univ, Fac Sci, Dept Chem, TR-35100 Bornova, Izmir, Turkiye
[2] Ege Univ, Translat Pulm Res Ctr EgeSAM, TR-35100 Bornova, Izmir, Turkiye
[3] Ege Univ, Fac Med, Dept Pulm Immunol & Allergy, TR-35100 Bornova, Izmir, Turkiye
[4] Ege Univ, Fac Sci, Dept Math, TR-35100 Bornova, Izmir, Turkiye
[5] Izmir Inst Technol, Dept Chem, TR-35430 Bornova, Izmir, Turkiye
关键词
Volatile organic biomarkers; Exhaled breath analysis; Untargeted biomarker screening; Lung cancer; Selected ion monitoring mode; Solid-phase microextraction; Conducting polymer; ORGANIC-COMPOUNDS; METABOLITES;
D O I
10.1016/j.microc.2024.112067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The diagnosis of diseases through monitoring of volatile organic compounds (VOCs) in exhaled breath (EB) holds great potential for clinical applications. However, a standardized method for VOC analysis in EB yet to be proposed. The present study presents an untargeted method for screening and identifying potential volatile biomarkers in EB by a lab-made solid phase microextraction (SPME) fiber. A polythiophene-based SPME fiber was produced by an electrochemical method and VOC sampling was performed under dynamic and controlled conditions. Following the sampling step, the adsorbed VOCs on the SPME fiber were analyzed using gas chromatography-mass spectrometry (GC-MS). The VOCs in EB were screened by the MS detector in selected ion monitoring (SIM) mode within the mass/charge (m/z) range of 13-94 values. Potential biomarkers among all detected VOCs in each subject's EB sample were identified through machine learning algorithms, employing a comparative analysis of distinctive retention times (RT) and peak areas between the lung cancer (LC) and control groups in two stages. In the initial stage of the study, the areas of all peaks observed in the SIM-GC-MS chromatograms of 25 LC and 51 control group subjects were integrated, and the resulting retention times and peak areas were recorded for subsequent analysis to identify potential biomarkers. A total of 1.346 distinct compounds were detected among the 76 subjects in this step, and statistical analysis using the LightGBM algorithm revealed the potential biomarkers for LC diagnosis. The PTh-SPME fibre successfully identified four novel cancer biomarkers in breath matrix: 4-heptenal, 4-methyl-1-octene, 1,2,3,4-tetrahydro-5,8-dimethyl-1-octylnaphthalene and tetrahydro-2-(2,5-undecadiynyloxy)-2H-pyran. In the second step of the study, the efficacy of the top ten selected biomarkers was evaluated in a cohort of 166 subjects, including 70 individuals with LC and 96 in the control group. The model achieved accuracy, area under the curve (AUC), and F Score values of 0.818, 0.816, and 0.817, respectively. The test model correctly predicted 27 out of 33 subjects between LC and control groups.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Analysis of volatile compounds from a malting process using headspace solid-phase micro-extraction and GC-MS
    Dong, Liang
    Piao, Yongzhe
    Zhang, Xiao
    Zhao, Changxin
    Hou, Yingmin
    Shi, Zhongping
    FOOD RESEARCH INTERNATIONAL, 2013, 51 (02) : 783 - 789
  • [32] Identification of volatile metabolites in human saliva from patients with oral squamous cell carcinoma via zeolite-based thin-film microextraction coupled with GC-MS
    Shigeyama, Hiroyo
    Wang, Tao
    Ichinose, Masatoshi
    Ansai, Toshihiro
    Lee, Seung-Woo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1104 : 49 - 58
  • [33] Development of a solid phase microextraction protocol for the GC-MS determination of volatile off-flavour compounds from citral degradation in oil-in-water emulsions
    Tian, Huaixiang
    Yang, Xiaoqing
    Ho, Chi-Tang
    Huang, Qingrong
    Song, Shiqing
    FOOD CHEMISTRY, 2013, 141 (01) : 131 - 138
  • [34] A novel method for the determination of three volatile organic compounds in exhaled breath by solid-phase microextraction-ion mobility spectrometry
    Allafchian, Ali Reza
    Majidian, Zahra
    Ielbeigi, Vahideh
    Tabrizchi, Mahmoud
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (03) : 839 - 847
  • [35] Optimization of Headspace Solid-phase Microextraction for GC-MS Analysis of Volatile Compounds Produced by Biocontrol Strain Bacillus subtilis CF-3 Using Response Surface Methodology
    Gao, Haiyan
    Xu, Xinxing
    Zeng, Qing
    Li, Peizhong
    FOOD SCIENCE AND TECHNOLOGY RESEARCH, 2017, 23 (04) : 583 - 593
  • [36] Thermal stability of foamed polysiloxane rubbers: Headspace analysis using solid phase microextraction and analysis of solvent extractable material using conventional GC-MS
    Hall, Alison D.
    Patel, Mogon
    POLYMER DEGRADATION AND STABILITY, 2006, 91 (10) : 2532 - 2539
  • [37] Heterogenic catalytic hydrolysis and analysis of natural pyrethrins in subcritical water coupled with solid phase microextraction (SPME) and GC-MS
    Martin Krappe
    Steven B. Hawthorne
    B. W. Wenclawiak
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 625 - 630
  • [38] Identification of volatile compounds in soybean at various developmental stages using solid phase microextraction
    Boué, SM
    Shih, BY
    Carter-Wientjes, CH
    Cleveland, TE
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (17) : 4873 - 4876
  • [39] Identification of volatile compounds in cantaloupe at various developmental stages using solid phase microextraction
    Beaulieu, JC
    Grimm, CC
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) : 1345 - 1352
  • [40] Selective determination of alkylmercury compounds in solid matrices after subcritical water extraction, followed by solid-phase microextraction and GC-MS
    Beichert, A
    Padberg, S
    Wenclawiak, BW
    APPLIED ORGANOMETALLIC CHEMISTRY, 2000, 14 (09) : 493 - 498