Magnetic resonance imaging as a noninvasive adjunct to conventional assessment of functional differences between kidneys in vivo and during ex vivo normothermic machine perfusion

被引:2
作者
Hamelink, Tim L. [1 ]
Ogurlu, Baran [1 ]
Pamplona, Carolina C. [1 ]
Castelein, Johannes [2 ,3 ]
Bennedsgaard, Sigrid S. [4 ]
Qi, Haiyun [5 ]
Weiss, Thomas [5 ]
Lantinga, Veerle A. [1 ]
Pool, Merel B. F. [1 ]
Laustsen, Christoffer [6 ]
Jespersen, Bente [5 ,7 ]
Leuvenink, Henri G. D. [1 ]
Ringgaard, Steffen [6 ]
Borra, Ronald J. H. [2 ]
Keller, Anna K. [1 ,4 ,7 ]
Moers, Cyril [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Surg Organ Donat & Transplantat, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Groningen, Netherlands
[3] Univ Copenhagen, Fac Hlth & Med Sci, Dept Biomed Sci, Copenhagen, Denmark
[4] Aarhus Univ Hosp, Dept Urol, Aarhus, Denmark
[5] Aarhus Univ Hosp, Dept Renal Med, Aarhus, Denmark
[6] Aarhus Univ Hosp, MR Res Ctr, Dept Clin Med, Aarhus, Denmark
[7] Aarhus Univ Hosp, Dept Clin Med, Aarhus, Denmark
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
kidney transplantation; organ donation; renal normothermic machine; perfusion; magnetic resonance imaging; QUALITY ASSESSMENT; ISCHEMIA; INJURY; IMPAIRMENT; OXYGEN; FLOW;
D O I
10.1016/j.ajt.2024.04.001
中图分类号
R61 [外科手术学];
学科分类号
摘要
Normothermic machine perfusion (NMP) is increasingly considered for pretransplant kidney quality assessment. However, fundamental questions about differences between in vivo and ex vivo renal function, as well as the impact of ischemic injury on ex vivo physiology, remain unanswered. This study utilized magnetic resonance imaging (MRI), alongside conventional parameters to explore differences between in vivo and ex vivo renal function and the impact of warm ischemia on a kidney's behavior ex vivo. Renal MRI scans and samples were obtained from living pigs (n = 30) in vivo. Next, kidney pairs were procured and exposed to minimal, or 75 minutes of warm ischemia, followed by 6 hours of hypothermic machine perfusion. Both kidneys simultaneously underwent 6-hour ex vivo perfusion in MRI-compatible NMP circuits to obtain multiparametric MRI data. Ischemically injured ex vivo kidneys showed a significantly altered regional blood flow distribution compared to in vivo and minimally damaged organs. Both ex vivo groups showed diffusion restriction relative to in vivo. Our findings underscore the differences between in vivo and ex vivo MRI-based renal characteristics. Therefore, when assessing organ viability during NMP, it should be considered to incorporate parameters beyond the conventional functional markers that are common in vivo.
引用
收藏
页码:1761 / 1771
页数:11
相关论文
共 37 条
[1]   Diffusion-weighted magnetic resonance imaging to assess diffuse renal pathology: a systematic review and statement paper [J].
Caroli, Anna ;
Schneider, Moritz ;
Friedli, Iris ;
Ljimani, Alexandra ;
De Seigneux, Sophie ;
Boor, Peter ;
Gullapudi, Latha ;
Kazmi, Isma ;
Mendichovszky, Iosif A. ;
Notohamiprodjo, Mike ;
Selby, Nicholas M. ;
Thoeny, Harriet C. ;
Grenier, Nicolas ;
Vallee, Jean-Paul .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33 :II29-II40
[2]   Effects of kidney perfusion on renal stiffness and tissue fluidity measured with tomoelastography in an MRI-compatible ex vivo model [J].
Castelein, Johannes ;
Pamplona, Carolina ;
Armstrong Junior, Roberto ;
dos Santos, Marina Vidal ;
Sack, Ingolf ;
Dierckx, Rudi ;
Moers, Cyril ;
Borra, Ronald .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
[3]   BOLD-MRI assessment of intrarenal oxygenation and oxidative stress in patients with chronic kidney allograft dysfunction [J].
Djamali, Arjang ;
Sadowski, Elizabeth A. ;
Muehrer, Rebecca J. ;
Reese, Shannon ;
Smavatkul, Chanigan ;
Vidyasagar, Aparna ;
Fain, Sean B. ;
Lipscomb, Ryan C. ;
Hullett, Debra H. ;
Samaniego-Picota, Millie ;
Grist, Thomas M. ;
Becker, Bryan N. .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2007, 292 (02) :F513-F522
[4]   Evaluation of renal allograft function early after transplantation with diffusion-weighted MR imaging [J].
Eisenberger, Ute ;
Thoeny, Harriet C. ;
Binser, Tobias ;
Gugger, Mathias ;
Frey, Felix J. ;
Boesch, Chris ;
Vermathen, Peter .
EUROPEAN RADIOLOGY, 2010, 20 (06) :1374-1383
[5]   Oxygen and renal metabolism [J].
Epstein, FH .
KIDNEY INTERNATIONAL, 1997, 51 (02) :381-385
[6]  
Goyal Ankur, 2012, Indian J Radiol Imaging, V22, P155, DOI 10.4103/0971-3026.107169
[7]   Association between native T1 mapping of the kidney and renal fibrosis in patients with IgA nephropathy [J].
Graham-Brown, M. P. ;
Singh, A. ;
Wormleighton, J. ;
Brunskill, N. J. ;
McCann, G. P. ;
Barratt, J. ;
Burton, J. O. ;
Xu, G. .
BMC NEPHROLOGY, 2019, 20 (1)
[8]   Renal Normothermic Machine Perfusion: The Road Toward Clinical Implementation of a Promising Pretransplant Organ Assessment Tool [J].
Hamelink, Tim L. ;
Ogurlu, Baran ;
De Beule, Julie ;
Lantinga, Veerle A. ;
Pool, Merel B. F. ;
Venema, Leonie H. ;
Leuvenink, Henri G. D. ;
Jochmans, Ina ;
Moers, Cyril .
TRANSPLANTATION, 2022, 106 (02) :268-279
[9]   The effect of warm ischemic time on renal function and injury in the isolated hemoperfused kidney [J].
Harper, Simon J. F. ;
Hosgood, Sarah A. ;
Waller, Helen L. ;
Yang, Bin ;
Kay, Mark D. ;
Goncalves, Ines ;
Nicholson, Michael L. .
TRANSPLANTATION, 2008, 86 (03) :445-451
[10]   Normothermic machine perfusion for the assessment and transplantation of declined human kidneys from donation after circulatory death donors [J].
Hosgood, S. A. ;
Thompson, E. ;
Moore, T. ;
Wilson, C. H. ;
Nicholson, M. L. .
BRITISH JOURNAL OF SURGERY, 2018, 105 (04) :388-394