This paper presents the findings of a study on dose rate distribution in air and water phantoms, recorded using Gafchromic films. Low energy accelerator with X-ray tube (NALR), a system developed at the National Centre for Nuclear Research (NCBJ), generated by the dose rates. The primary objective of this research was to employ the X-ray tube as a source of X-ray radiation and assess dosimetry techniques using radiochromic films for radiological protection purposes. Gafchromic MD-55-V2 and EBT films were utilized for measurements. Two-dimensional measurements with Gafchromic dosimetry films were compared against ionization chambers AP 2.0 (in water) and PTW-23342 (in air) to validate radiation dose rate distributions. Furthermore, the film response over different days post-exposure highlights the importance of scanning radiochromic films on the first day after exposure.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 12 条
  • [1] External beam radiation therapy with kilovoltage x-rays
    Breitkreutz, Dylan Y.
    Weil, Michael D.
    Bazalova-Carter, Magdalena
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 : 103 - 112
  • [2] Absorption spectra variations of EBT radiochromic film from radiation exposure
    Butson, MJ
    Cheung, T
    Yu, PKN
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) : N135 - N140
  • [3] Radiochromic Films for the Two-Dimensional Dose Distribution Assessment
    Casolaro, Pierluigi
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (05): : 1 - 16
  • [4] Absorption spectroscopy of EBT model GAFCHROMIC™ film
    Devic, Slobodan
    Tomic, Nada
    Pang, Zhiyu
    Seuntjens, Jan
    Podgorsak, Ervin B.
    Soares, Christopher G.
    [J]. MEDICAL PHYSICS, 2007, 34 (01) : 112 - 118
  • [5] Intraoperative radiation therapy in the treatment of early-stage breast cancer utilizing xoft axxent electronic brachytherapy
    Dickler, Adam
    Ivanov, Olga
    Francescatti, Darius
    [J]. WORLD JOURNAL OF SURGICAL ONCOLOGY, 2009, 7
  • [6] Present state and issues in IORT Physics
    Hensley, Frank W.
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [7] Intraoperative radiation therapy (IORT) in head and neck cancer A systematic review
    Kyrgias, George
    Hajiioannou, Jiannis
    Tolia, Maria
    Kouloulias, Vassilios
    Lachanas, Vasileios
    Skoulakis, Charalambos
    Skarlatos, Ioannis
    Rapidis, Alexandros
    Bizakis, Ioannis
    [J]. MEDICINE, 2016, 95 (50) : e5035
  • [8] High-dose-rate intraoperative radiation therapy: the nuts and bolts of starting a program
    Moningi, Shalini
    Armour, Elwood P.
    Terezakis, Stephanie A.
    Efron, Jonathan E.
    Gearhart, Susan L.
    Bivalacqua, Trinity J.
    Kumar, Rachit
    Le, Yi
    Ng, Sook Kien
    Wolfgang, Christopher L.
    Zellars, Richard C.
    Ellsworth, Susannah G.
    Ahuja, Nita
    Herman, Joseph M.
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 99 - 105
  • [9] Pilar A, 2017, ECANCERMEDICALSCIENC, V11, DOI 10.3332/ecancer.2017.750
  • [10] Salari E., 2023, Advances in dosimetry and new trends in radiopharmaceuticals, DOI [10.5772/intechopen.1002727, DOI 10.5772/INTECHOPEN.1002727]