Impact of drainage pipe vapor intrusion pathways on sub-slab depressurization system mitigation performance

被引:0
作者
Ding, Ning [1 ]
Hou, Chenglin [2 ]
Li, Hongrui [2 ]
Chen, Haoming [1 ]
Dahlen, Paul [3 ]
Johnson, Paul C. [4 ]
Yao, Yijun [5 ]
Guo, Yuanming [1 ,2 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Environm & Biol Engn, Nanjing 210094, Peoples R China
[2] Norendar Int LTD, Shijiazhuang 050000, Peoples R China
[3] Arizona State Univ, Sch Sustainable Engn & Built Environm, Ira A Fulton Sch Engn, Tempe, AZ 85287 USA
[4] Colorado Sch Mines, Dept Civil & Environm Engn, Golden, CO 80401 USA
[5] Chinese Acad Sci, Inst Soil Sci, Key Lab Soil Environm & Pollut Remediat, Nanjing 210008, Peoples R China
关键词
Vapor intrusion; Sub-slab depressurization; Preferential pathway; VI numerical model; VI mitigation; SOIL; VOCS;
D O I
10.1016/j.jhazmat.2024.136277
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Sub-slab depressurization (SSD) systems are the most commonly employed technology for mitigating vapor intrusion (VI) impact to indoor air. However, as cases involving preferential VI pathways (e.g. sewers, land drains) are being reported, the efficacy of SSD systems to reduce VI impacts from such pathways is being questioned. In this study, field test and numerical modeling were performed to evaluate the effectiveness of an SSD system for the case of VI involving a drainage pipe preferential pathway. Field tests investigated the SSD performance at the study house under conditions with and without the impact of a drainage pipe pathway. A numerical model was developed to explore the influence of the preferential pathway on SSD mitigation under different scenarios. Both field and simulation results indicated that the sub-slab drainage system inhibits the performance of the SSD, consequently requiring a greater level of flow and depressurization for the system to protect the building. In addition, the SSD caused higher sub-slab vapor concentrations than under natural condition in both field testing and simulation results, which raised concerns for potential VI risk under standard
引用
收藏
页数:9
相关论文
共 34 条
  • [11] Comparing Vapor Intrusion Mitigation System Performance for VOCs and Radon
    Lutes, Christopher C.
    Truesdale, Robert S.
    Cosky, Brian W.
    Zimmerman, John H.
    Schumacher, Brian A.
    [J]. REMEDIATION-THE JOURNAL OF ENVIRONMENTAL CLEANUP COSTS TECHNOLOGIES & TECHNIQUES, 2015, 25 (04): : 7 - 26
  • [12] Vapor Intrusion Investigations and Decision-Making: A Critical Review
    Ma, Jie
    McHugh, Thomas
    Beckley, Lila
    Lahvis, Matthew
    DeVaull, George
    Jiang, Lin
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (12) : 7050 - 7069
  • [13] Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex
    McHugh, Thomas
    Beckley, Lila
    Sullivan, Terry
    Lutes, Chris
    Truesdale, Robert
    Uppencamp, Rob
    Cosky, Brian
    Zimmerman, John
    Schumacher, Brian
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 598 : 772 - 779
  • [14] Evaluation of Vapor Intrusion Using Controlled Building Pressure
    McHugh, Thomas E.
    Beckley, Lila
    Bailey, Danielle
    Gorder, Kyle
    Dettenmaier, Erik
    Rivera-Duarte, Ignacio
    Brock, Samuel
    MacGregor, Ian C.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (09) : 4792 - 4799
  • [15] NAZAROFF WW, 1988, RADIAT PROT DOSIM, V24, P199
  • [16] Riis C., 2010, Remediat Chlorinated Recalcitrant Compd
  • [17] Occurrence of chlorinated volatile organic compounds (VOCs) in a sanitary sewer system: Implications for assessing vapor intrusion alternative pathways
    Roghani, Mohammadyousef
    Jacobs, Olivia P.
    Miller, Anthony
    Willett, Evan J.
    Jacobs, James A.
    Viteri, C. Ricardo
    Shirazi, Elham
    Pennell, Kelly G.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 616 : 1149 - 1162
  • [18] Case study of sub-slab depressurization for a building located over VOC-contaminated ground
    Rydock, JP
    Skåret, E
    [J]. BUILDING AND ENVIRONMENT, 2002, 37 (12) : 1343 - 1347
  • [19] Sugg Z., 2007, ASSESSING US FARM DR
  • [20] U.S. Environment Protection Agency, 1993, Radon reduction techniques for existing detached houses -Technical guidance (third edition) for active soil depressurization systems