Investigation of chromatographic procedures for the analysis of cationic impurities in uranium and plutonium matrices by ICP-OES and ICP-MS

被引:1
作者
Hernandez, Marion [1 ]
Quemet, Alexandre [1 ]
Montreuil, Laure [1 ]
Maillard, Christophe [1 ]
Baghdadi, Sarah [1 ]
机构
[1] Univ Montpellier, CEA, DES, ISEC,DMRC, Marcoule, France
关键词
Impurities analysis; Uranium; Plutonium; ICP-MS; ICP-OES; Chromatography; Separation; MASS-SPECTROMETRY; EXTRACTION CHROMATOGRAPHY; COLLISION CELL; ENVIRONMENTAL-SAMPLES; TRACE IMPURITIES; SEPARATION; PLASMA; IRON; THORIUM; OXIDE;
D O I
10.1016/j.sab.2025.107136
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Four different separation protocols were tested to analyze several cations in a U-Pu matrix by inductively coupled plasma - optical emission spectrometry (ICP-OES) or mass spectrometry (ICP-MS): UTEVA resin with HNO3 eluent, UTEVA resin with HNO3/H2C2O4 eluent, UTEVA resin with HNO3/H2O2 eluent and TEVA resin with HNO3 eluent. It was shown that none of the twenty nine tested cations (Al, Ag, B, Ca, Cd, Ce, Cr, Cu, Fe, Ga, La, Mg, Mn, Mo, Na, Nd, Ni, Pb, Pd, Rh, Sb, Se, Si, Sn, Sr, Ti, V, Y and Zn) was retained onto the resin, with recovery yields between 80 and 120 %. Meanwhile, the U-Pu matrix was retained onto the resin and was eliminated from the fraction containing the cations. After initial testing, two of the protocols were chosen: UTEVA resin with HNO3/H2C2O4 eluent and UTEVA resin with HNO3/H2O2 eluent thanks to their efficacy and practicality. Then, the two selected protocols were applied to a uranium oxide certified reference material to validate them. Twenty three out of the thirty one impurities presents in the material (Ag, Ba, Be, Bi, Cd, Co, Cr, Cu, Dy, Eu, Fe, Gd, In, Li, Mo, Ni, Pb, Sm, Sn, Ti, V, W and Zr) were determined with good recoveries. Th was fixed onto the resin. Based on theses results, it seems possible to analyze the forty one impurities in a U-Pu material by optimizing the operating conditions. These two protocols were used to study the presence of impurities in a Pu-based material to ensure the purity of the materials. Detection limits in the order of mu g g- 1 powder were obtained.
引用
收藏
页数:8
相关论文
共 43 条
[1]   Extraction chromatography of the Rf homologs, Zr and Hf, using TEVA and UTEVA resins in HCl, HNO3, and H2SO4 media [J].
Alfonso, M. C. ;
Bennett, M. E. ;
Folden, C. M., III .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (02) :1529-1536
[2]  
[Anonymous], 2008, International vocabulary of metrology-Basic and general concepts and associated terms (VIM), JCGM 2008
[3]  
[Anonymous], 2008, Evaluation of Measurement Data - Guide to the Expression of Uncertainty in Measurement, P100, DOI DOI 10.1373/CLINCHCM.2003.030528
[4]  
[Anonymous], 2006, IUPAC Compendium of Chemical Terminology, V3rd, DOI [10.1351/goldbook.HT06787, DOI 10.1351/GOLDBOOK.C01045]
[5]  
ASTM, 2024, C1432-23, DOI [10.1520/C1432-23, DOI 10.1520/C1432-23]
[6]  
Baker R. D., 1983, Los Alamos Science
[7]   Space charge effects and internal standardization in a four ion lenses interface: What is changing in quadrupole inductively coupled plasma mass spectrometry? [J].
Barros, Ariane I. ;
Pinheiro, Fernanda C. ;
Nobrega, Joaquim A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 167
[8]   Determination of impurities in uranium matrices by time-of-flight ICP-MS using matrix-matched method [J].
Burger, S. ;
Riciputi, L. R. ;
Bostick, D. A. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 274 (03) :491-505
[9]   SIMULTANEOUS DETERMINATION OF AMERICIUM AND PLUTONIUM BY INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CLAUDON, X ;
BIROLLEAU, JC ;
LAVERGNE, M ;
MICHE, B ;
BERGEY, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :407-411
[10]   Coprecipitation with calcium hydroxide for determination of iron in fish otoliths by collision cell ICP-MS [J].
Daniels, Stephanie L. ;
Arslan, Zikri .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05) :584-590