Dual-Contrast Agent with Nanoparticle and Molecular Components in Photon-Counting Computed Tomography: Assessing Articular Cartilage Health

被引:0
作者
Paakkari, Petri [1 ,2 ]
Inkinen, Satu I. [3 ,4 ]
Jantti, Jiri [1 ,2 ]
Tuppurainen, Juuso [1 ,2 ]
Fugazzola, Maria C. [5 ]
Joenathan, Anisha [6 ,7 ,8 ]
Ylisiurua, Sampo [9 ,10 ]
Nieminen, Miika T. [10 ]
Kroger, Heikki [11 ,12 ]
Mikkonen, Santtu [1 ,13 ]
van Weeren, Rene [5 ]
Snyder, Brian D.
Toyras, Juha [1 ]
Honkanen, Miitu K. M. [2 ]
Matikka, Hanna [2 ]
Grinstaff, Mark W. [6 ,7 ,8 ]
Honkanen, Juuso T. J. [14 ]
Makela, Janne T. A. [1 ,2 ]
机构
[1] Univ Eastern Finland, Dept Tech Phys, Kuopio 70211, Finland
[2] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio, Finland
[3] Univ Helsinki, Diagnost Ctr, Helsinki, Finland
[4] Helsinki Univ Hosp, Helsinki, Finland
[5] Univ Utrecht, Fac Vet Med, Dept Clin Sci, Utrecht, Netherlands
[6] Boston Univ, Dept Biomed Engn, Boston, MA USA
[7] Boston Univ, Dept Chem, Boston, MA USA
[8] Boston Univ, Dept Med, Boston, MA USA
[9] Oulu Univ Hosp, Oulu, Finland
[10] Univ Oulu, Res Unit Med Imaging Phys & Technol, Oulu, Finland
[11] Kuopio Univ Hosp, Dept Orthopaed & Traumatol, FIN-70211 Kuopio, Finland
[12] Univ Eastern Finland, Musculoskeletal Res Unit, Kuopio, Finland
[13] Univ Eastern Finland, Dept Environm & Biol Sci, Kuopio, Finland
[14] Kuopio Univ Hosp, Ctr Oncol, Radiotherapy Dept, Kuopio 70029, Finland
关键词
Photon-counting detector; Contrast-enhanced computed tomography; Nanoparticle; Material decomposition; Osteoarthritis; CT PRINCIPLES; VISUALIZATION; DEGENERATION; CHARGE; RATIO;
D O I
10.1007/s10439-025-03715-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Photon-counting detectors (PCDs) are cutting-edge technology that enable spectral computed tomography (CT) imaging with a single scan. Spectral imaging is particularly effective in contrast-enhanced CT (CECT) imaging, especially when multiple contrast agents are utilized, as materials are distinguishable based on their unique X-ray absorption. One application of CECT is joint imaging, where it assesses the structure and composition of articular cartilage soft tissue. This evaluates articular cartilage and reveals compositional changes associated with early-stage osteoarthritis (OA) using a photon-counting detector CT (PCD-CT) technique combined with a dual-contrast agent method. Methods A dual-contrast agent combination was used, consisting of proteoglycan-binding cationic tantalum oxide nanoparticles, developed in our lab, and a commercial non-ionic iodinated iodixanol agent. Ex vivo equine stifle joint cartilage samples (N = 30) were immersed in the contrast agent bath for 96 hours and imaged at multiple timepoints for analysis of proteoglycan, collagen, and water contents as well as collagen orientation, histological scoring, and biomechanical parameters. Results By analyzing contrast agent concentrations, the technique provided a simultaneous assessment of the solid constituents and function of cartilage. Contrast agent diffusion depended on contrast agent composition and was significantly different between healthy and early-stage OA groups within 12 hours. Conclusion The present study shows the promising utility of the dual-contrast PCD-CT technique for articular cartilage assessment and early-stage OA detection.
引用
收藏
页码:1423 / 1438
页数:16
相关论文
共 57 条
  • [1] Epidemiology of osteoarthritis
    Allen, K. D.
    Thoma, L. M.
    Golightly, Y. M.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2022, 30 (02) : 184 - 195
  • [2] VARIATIONS IN THE INTRINSIC MECHANICAL PROTERTIES OF HUMAN ARTICULAR-CARTILAGE WITH AGE, DEGENERATION, AND WATER-CONTENT
    ARMSTRONG, CG
    MOW, VC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (01) : 88 - 94
  • [3] Effects of human articular cartilage constituents on simultaneous diffusion of cationic and nonionic contrast agents
    Bhattarai, Abhisek
    Makela, Janne T. A.
    Pouran, Behdad
    Kroger, Heikki
    Weinans, Harrie
    Grinstaff, Mark W.
    Toyras, Juha
    Turunen, Mikael J.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (04) : 771 - 779
  • [4] Dual contrast in computed tomography allows earlier characterization of articular cartilage over single contrast
    Bhattarai, Abhisek
    Pouran, Behdad
    Makela, Janne T. A.
    Shaikh, Rubina
    Honkanen, Miitu K. M.
    Prakash, Mithilesh
    Kroger, Heikki
    Grinstaff, Mark W.
    Weinans, Harrie
    Jurvelin, Jukka S.
    Toyras, Juha
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (10) : 2230 - 2238
  • [5] Quantitative Dual Contrast CT Technique for Evaluation of Articular Cartilage Properties
    Bhattarai, Abhisek
    Honkanen, Juuso T. J.
    Myller, Katariina A. H.
    Prakash, Mithilesh
    Korhonen, Miitu
    Saukko, Annina E. A.
    Viren, Tuomas
    Joukainen, Antti
    Patwa, Amit N.
    Kroger, Heikki
    Grinstaff, Mark W.
    Jurvelin, Jukka S.
    Toyras, Juha
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2018, 46 (07) : 1038 - 1046
  • [6] Contrast-Enhanced Micro-Computed Tomography for 3D Visualization and Quantification of Glycosaminoglycans in Different Cartilage Types
    Boos, Manuela A.
    Grinstaff, Mark W.
    Lamande, Shireen R.
    Stok, Kathryn S.
    [J]. CARTILAGE, 2021, 13 (2_SUPPL) : 486S - 494S
  • [7] Bursac P M, 1996, Tissue Eng, V2, P141, DOI 10.1089/ten.1996.2.141
  • [8] Chellini D, 2020, RADIOL TECHNOL, V91, p561CT
  • [9] Cole LE, 2015, NANOMEDICINE-UK, V10, P321, DOI [10.2217/NNM.14.171, 10.2217/nnm.14.171]
  • [10] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)