Polarity-Sensitive fluorescent probes based on triphenylamine for fluorescence lifetime imaging of lipid droplets

被引:1
作者
Wang, Qian [1 ]
Li, Dongmei [2 ]
Zhang, Ze [3 ]
Shen, Lingyi [2 ]
Xu, Hong [2 ]
Wang, Zhiyong [2 ]
Redshaw, Carl [4 ]
Zhang, Qilong [2 ]
机构
[1] Guizhou Med Univ, Translat Med Res Ctr, Guiyang 550025, Peoples R China
[2] Guizhou Med Univ, Sch Basic Med Sci, Guiyang 550025, Peoples R China
[3] Guizhou Med Univ, Sch Biol & Engn, Sch Hlth Med Modern Ind, Guiyang 550025, Peoples R China
[4] Univ Hull, Sch Nat Sci, Chem, Kingston Upon Hull HU6 7RX, Yorks, England
基金
中国国家自然科学基金;
关键词
Fluorescence imaging; Targeted lipid droplets; Triphenylamine; Polar-responsive; Fluorescence lifetime; Non-alcoholic fatty liver disease;
D O I
10.1016/j.saa.2024.125694
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Non-alcoholic fatty liver disease (NAFLD) is a disease closely associated with metabolic abnormalities. Lipid droplets (LDs) serve as organelles that store intracellular neutral lipids and maintain cellular energy homeostasis. Their abnormalities can cause metabolic disorders and disease, which is also one of the distinctive characteristics of NAFLD patients. However, the correlation between the polarity of LDs and NAFLD is easily overlooked. To monitor the polarity changes in LDs in order to assess the progression of NAFLD, triphenylamine was used as the electron donor (D), pyridine as the electron acceptor (A) and thiazolo[5,4-d]thiazole (TTz) as pi bridge in this study. The structure was modified by introducing different substituents at the triphenylamine to obtain a series of D-pi-A structural polar-responsive asymmetric thiazolo[5,4-d]thiazole (aTTz) fluorescent probes with different push-pull electron effects and steric hindrance. The fluorescent probes, which exhibit distinct fluorescence emission spectra in solutions with varying polarities, demonstrate excellent polarity-sensitive properties, and the displacement of the maximum emission wavelength varies from 125 to 150 nm. Meanwhile, the fluorescent probes exhibited low dark toxicity of cells and can specifically image lipid droplets, with a localization coefficient of more than 0.84 when imaging, and can be applied to the fluorescence imaging of C. elegans. Furthermore, the polar response properties of the fluorescent probes were used to distinguish normal liver tissue and nonalcoholic fatty liver tissue by fluorescence lifetime microscopic imaging (FLIM), thus providing a molecular tool for the diagnosis of NAFLD.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A distyrylbenzene-based fluorescent probe with high photostability and large Stokes shift for STED nanoscopy imaging of cellular lipid droplets
    Liu, Guannan
    Dai, Jianan
    Zhou, Ri
    Peng, Guishan
    Wang, Chenguang
    Yan, Xu
    Jia, Xiaoteng
    Liu, Xiaomin
    Gao, Yuan
    Wang, Lijun
    Lu, Geyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 353
  • [32] Fluorescence lifetime imaging microscopy based on a synchroscan streak camera
    Qu, J
    Li, J
    Niu, HB
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XI, 2004, 5 (13): : 250 - 256
  • [33] A new organic molecular probe as a powerful tool for fluorescence imaging and biological study of lipid droplets
    Zhou, Ri
    Wang, Chenguang
    Liang, Xishuang
    Liu, Fangmeng
    Sun, Peng
    Yan, Xu
    Jia, Xiaoteng
    Liu, Xiaomin
    Wang, Yue
    Lu, Geyu
    THERANOSTICS, 2023, 13 (01): : 95 - 105
  • [34] D-π-A-π-D type solvatochromic fluorescence probes based on triphenylamine: Synthesis, photophysical properties and application
    Chen, Zhen-E
    Qi, Qiang-long
    Zhang, Hai
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 238
  • [35] Selective and sensitive detection of Hg2+based on thiazolyl substituted triphenylamine AIE fluorescent probe
    Yu, Hao
    Xiao, Wenzhe
    Zhang, Guaiping
    Ma, Yanrui
    Qiu, Bin
    Xu, Xiuling
    MICROCHEMICAL JOURNAL, 2025, 211
  • [36] Labeling selectivity of lipid droplets fluorescent probes: Twisted intramolecular charge transfer (TICT) vs intramolecular charge transfer (ICT)
    Zhou, Ri
    Liu, Guannan
    Fu, Shengjie
    Zheng, Huanlong
    Li, Di
    Dai, Jianan
    Wei, Jinbei
    Li, Bai
    Wang, Chenguang
    Lu, Geyu
    BIOSENSORS & BIOELECTRONICS, 2024, 264
  • [37] Classification of skin cancer based on fluorescence lifetime imaging and machine learning
    Yang, Qianqian
    Qi, Meijie
    Wu, Zhaoqing
    Liu, Lixin
    Gao, Peng
    Qu, Junle
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS X, 2020, 11553
  • [38] Recent Progress of Activity-Based Fluorescent Probes for Imaging Leucine Aminopeptidase
    Li, Ze-Jun
    Wang, Cai-Yun
    Xu, Liang
    Zhang, Zhen-Yu
    Tang, Ying-Hao
    Qin, Tian-Yi
    Wang, Ya-Long
    BIOSENSORS-BASEL, 2023, 13 (07):
  • [39] An ultra-sensitive near-infrared fluorescent probe based on triphenylamine with high selectivity detecting the keratin
    Liu, Mingming
    Cao, Jian
    Tu, Yajing
    Huang, Cuiping
    Zhang, Meijuan
    Zheng, Junying
    ANALYTICAL BIOCHEMISTRY, 2022, 646
  • [40] Estimation of the content of lipids composing endothelial lipid droplets based on Raman imaging
    Pacia, Marta Z.
    Majzner, Katarzyna
    Czamara, Krzysztof
    Sternak, Magdalena
    Chlopicki, Stefan
    Baranska, Malgorzata
    BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2020, 1865 (09):