Seismic behavior of full-scale precast assembly frame joints of special-shaped columns

被引:0
|
作者
Zhang, Junfei [1 ]
Zhao, Chenxu [1 ]
Shang, Fuying [2 ]
Wang, Ling [1 ,3 ]
Wang, Ling [1 ,3 ]
Chen, Junlin [4 ]
Zhang, Lei [1 ]
Nehdi, Moncef L. [5 ]
机构
[1] Hebei Univ Technol, Sch Civil & Transportat Engn, Tianjin 300401, Peoples R China
[2] Envis Energy Co Ltd, Wuxi 214400, Peoples R China
[3] China Construct First Grp Corp Ltd, Beijing, Peoples R China
[4] Hebei Univ Technol, Arizona Coll Technol, Tianjin 300401, Peoples R China
[5] McMaster Univ, Dept Civil Engn, Hamilton, ON L8S 4M6, Canada
关键词
Seismic behavior; Precast concrete structure; Precast beam-column joint; Specially shaped column; Quasi-static loading test; CONCRETE; CONNECTION; PERFORMANCE; BUILDINGS; DESIGN; TESTS; ASH;
D O I
10.1016/j.istruc.2025.108781
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The utilization of precast reinforced concrete frames is widespread in the construction industry. However, among all components of the frame structure, the joint is considered the most vulnerable and critical during horizontal seismic activity. This study aims to investigate the seismic performance of the joints of an I-shaped assembled monolithic column, a T-shaped assembled monolithic column and a T-shaped fully precast assembly column. This investigation studies the failure mode, crack pattern, strain curve, load-displacement curves, characteristic point and ductility, load-bearing and deformation capacity, strength and stiffness degradation, and energy dissipation capacity of the joints. The findings reveal that the I-shaped column frame joint experiences shear failure, while the T-shaped column frame joint fails at the ends of the beams. Stiffness degradation of column frame joints with the same cross-section is found to be similar. The assembled monolithic beam-column joint displays significant vertical interface cracking after prefabrication and casting, with a gradual decrease observed in the skeleton curve. In contrast, the T-shaped fully precast assembly column frame joint shows weak plastic deformation capacity at the beam hinges, leading to significant angle slip during bending failure and a severe pinching phenomenon in the hysteresis curve. Furthermore, the T-shaped column flange, compared to the Ishaped column section, increases the joint height and substantially enhances its shear bearing capacity, albeit at the expense of weakened bending bearing deformation capacity. This study develops an assembly connection method suitable for the special-shaped precast column-frame structural system.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Seismic Behavior of Frames with Special-Shaped Concrete-Filled Steel Tubular Columns and H-Shaped Steel Beams
    Yang, Yuanlong
    Yang, Weiqi
    Tang, Xin
    Cheng, Guozhong
    ACI STRUCTURAL JOURNAL, 2022, 119 (03) : 29 - 42
  • [22] Full-scale Experimental and Numerical Investigations on Seismic Performance of Square RC Frame Columns with Hollow Sections
    Yang, Cantian
    Xie, Linlin
    Li, Aiqun
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (01) : 427 - 448
  • [23] Experimental research on seismic behavior of joints of specially shaped columns
    Rong, Xian
    Zhang, Jianxin
    Li, Yanyan
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2013, 34 (02): : 169 - 175
  • [24] Research on seismic behavior of full-scale high-strength concrete frame columns with high axial compression ratios
    Zhang, Guojun
    Liu, Jianxin
    Su, Qing
    Lu, Xilin
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 657 - +
  • [25] Study on seismic performance of SRC special-shaped interior joints in NPP
    Xu, Zhen-Hua
    Bai, Guo-Liang
    Zhao, Jin-Quan
    Liu, Biao
    ENGINEERING STRUCTURES, 2021, 234
  • [26] Experimental and Analytical Study of Seismic Behavior of Special-Shaped Multicell Composite Concrete-Filled Steel Tube Columns
    Yin, Fei
    Xue, Su-Duo
    Cao, Wan-Lin
    Dong, Hong-Ying
    Wu, Hai-Peng
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (01)
  • [27] The analysis on the seismic behavior of T-shaped prefabricated special-shaped CFST with rectangular multi-cell columns
    Cui, Wenbin
    Wang, Lai
    Chen, Huirong
    Chen, Haitao
    Liu, Su
    STRUCTURES, 2020, 28 : 803 - 815
  • [28] Coupled translational-torsional response for SRC frame with special-shaped columns under earthquake
    Zhou, Chaofeng
    Xue, Jianyang
    Hu, Zongbo
    Liu, Zuqiang
    JOURNAL OF BUILDING ENGINEERING, 2020, 31
  • [29] Experimental Study of the Seismic Behavior of the Frame Composed of Special-Shaped Concrete-Filled Square Steel Tube Columns and Steel Plate Shear Walls
    Yu J.
    Zhang X.
    Zheng D.
    Li L.
    Yan X.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2019, 52 : 38 - 45
  • [30] Seismic behaviour of full-scale lightly reinforced concrete columns under high axial loads
    Huy, Pham Phu Anh
    Yuen, Terry YP.
    Hung, Chung-Chan
    Mosalam, Khalid M.
    JOURNAL OF BUILDING ENGINEERING, 2022, 56