Comparing the improvement of occupant thermal comfort with local heating devices in cold environments

被引:1
|
作者
Zhu, Xueyue [1 ,2 ]
Liu, Hong [1 ,2 ]
He, Mengyuan [1 ,2 ]
Wu, Yuxin [3 ]
Xiong, Fengwei [1 ,2 ]
Li, Baizhan [1 ,2 ]
机构
[1] Chongqing Univ, Joint Int Res Lab Green Bldg & Built Environm Mini, Chongqing, Peoples R China
[2] Chongqing Univ, Natl Ctr Int Res Low carbon & Green Bldg, Minist Sci & Technol, Chongqing, Peoples R China
[3] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal comfort; Personal comfort system; Local heating device; Heat gain; Cold environments; BROWN ADIPOSE-TISSUE; ENERGY-CONSUMPTION; FIELD SURVEY; BODY; FEET; HUOTONG; SYSTEMS; HANDS; ZONE;
D O I
10.1016/j.buildenv.2024.112350
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Local heating can improve the thermal comfort of occupants and save energy in buildings in cold environments; however, few studies have investigated the effects of heat-transfer modes. Here, we aimed to evaluate different local heating measurements including five-sided enclosed radiant panel, heating plate, and fan heater using climate chamber experiments with 20 participants in cold environments (14 degrees C). Skin temperature and thermal perception votes under two radiation types with low and high power, one condition of conduction, and one condition of convection were collected and analyzed (RL, RH, CD, and CV). Under conditions RH, CD, and CV, the investigated parameters significantly improved by three local heating devices, with foot skin temperature rising by 0.46 degrees C, foot thermal sensation rising by 1.25 scores, and overall thermal comfort increasing by 0.36 score; however, their energy consumption varied greatly. In contrast, no significant improvement was observed in the RL group. Additionally, direct application of heat at sites of palpable cold discomfort was not always the optimal approach, and heating other parts of the body may provide significant alleviation. We recommend that the surface temperature of local heaters based on conduction and radiation for heat transfer should not be lower than 40.38 degrees C and 52.15 degrees C, respectively. To maintain thermal comfort, air outlet temperature should not be lower than 34.56 degrees C for convection type heaters. Our results provide technical and experimental basis for designing energy-saving buildings.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Strategies for Thermal Comfort Improvement and Energy Savings in existing Office Buildings using Occupant Feedback
    Shetty, Sindhu S.
    Hoang Duc Chinh
    Panda, S. K.
    2015 IEEE INTERNATIONAL CONFERENCE ON BUILDING ENERGY EFFICIENCY AND SUSTAINABLE TECHNOLOGIES (ICBEST), 2015, : 23 - 27
  • [22] Occupant Satisfaction in 60 Radiant and All-air Building: Comparing Thermal Comfort and Acoustic Quality
    Karmann, Caroline
    Schiavon, Stefano
    Graham, Lindsay
    Raftery, Paul
    Bauman, Fred
    34TH INTERNATIONAL CONFERENCE ON PASSIVE AND LOW ENERGY ARCHITECTURE: SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT, VOL 2 (PLEA 2018), 2018, : 843 - 848
  • [23] Individual thermal profiles as a basis for comfort improvement in space and other environments
    Koscheyev, VS
    Coca, A
    Leon, GR
    Dancisak, MJ
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2002, 73 (12): : 1195 - 1202
  • [24] Impacts on Indoor Thermal Comfort and Heating Energy Use in Hellenic Dwellings from Occupant Behavioral Reactions
    Dascalaki, Elena G.
    Balaras, Constantinos A.
    APPLIED SCIENCES-BASEL, 2021, 11 (14):
  • [25] Modular Radiant Floor Heating and its Effect on Local Thermal Comfort
    Houtart, Diego
    Jhang, Han-Yun
    Licina, Dusan
    Khovalyg, Dolaana
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 3, 2025, 554 : 110 - 116
  • [26] A review of local radiant heating systems and their effects on thermal comfort and sensation
    Hooshmand, Seyed Mohammad
    Zhang, Hui
    Javidanfar, Hashem
    Zhai, Yongchao
    Wagner, Andreas
    ENERGY AND BUILDINGS, 2023, 296
  • [27] Experimental comparison of local direct heating to improve thermal comfort of workers
    Wang, Haiying
    Xu, Manshu
    Bian, Chunxiao
    BUILDING AND ENVIRONMENT, 2020, 177
  • [28] On the Use of Wearable Face and Neck Cooling Fans to Improve Occupant Thermal Comfort in Warm Indoor Environments
    Yang, Bin
    Lei, Tze-Huan
    Yang, Pengfei
    Liu, Kaixuan
    Wang, Faming
    ENERGIES, 2021, 14 (23)
  • [29] COMPENSATION OF ASYMMETRIC RADIATION FROM COLD WALLS BY THERMAL COMFORT - CONSCIOUS HEATING
    BANHIDI, L
    SOMOGYI, A
    FABO, L
    SIMON, T
    HEALTHY BUILDINGS 88, VOL 2: PLANNING, PHYSICS AND CLIMATE TECHNOLOGY FOR HEALTHIER BUILDINGS, 1988, : 363 - 369
  • [30] A thermal comfort evaluation on vehicular environments based on local human body thermal sensations
    Feng, Chaoqing
    Ma, Fengge
    Wang, Rui
    Li, Wei
    Gao, Jianfeng
    RESULTS IN ENGINEERING, 2023, 17