Comparing the improvement of occupant thermal comfort with local heating devices in cold environments

被引:1
|
作者
Zhu, Xueyue [1 ,2 ]
Liu, Hong [1 ,2 ]
He, Mengyuan [1 ,2 ]
Wu, Yuxin [3 ]
Xiong, Fengwei [1 ,2 ]
Li, Baizhan [1 ,2 ]
机构
[1] Chongqing Univ, Joint Int Res Lab Green Bldg & Built Environm Mini, Chongqing, Peoples R China
[2] Chongqing Univ, Natl Ctr Int Res Low carbon & Green Bldg, Minist Sci & Technol, Chongqing, Peoples R China
[3] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal comfort; Personal comfort system; Local heating device; Heat gain; Cold environments; BROWN ADIPOSE-TISSUE; ENERGY-CONSUMPTION; FIELD SURVEY; BODY; FEET; HUOTONG; SYSTEMS; HANDS; ZONE;
D O I
10.1016/j.buildenv.2024.112350
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Local heating can improve the thermal comfort of occupants and save energy in buildings in cold environments; however, few studies have investigated the effects of heat-transfer modes. Here, we aimed to evaluate different local heating measurements including five-sided enclosed radiant panel, heating plate, and fan heater using climate chamber experiments with 20 participants in cold environments (14 degrees C). Skin temperature and thermal perception votes under two radiation types with low and high power, one condition of conduction, and one condition of convection were collected and analyzed (RL, RH, CD, and CV). Under conditions RH, CD, and CV, the investigated parameters significantly improved by three local heating devices, with foot skin temperature rising by 0.46 degrees C, foot thermal sensation rising by 1.25 scores, and overall thermal comfort increasing by 0.36 score; however, their energy consumption varied greatly. In contrast, no significant improvement was observed in the RL group. Additionally, direct application of heat at sites of palpable cold discomfort was not always the optimal approach, and heating other parts of the body may provide significant alleviation. We recommend that the surface temperature of local heaters based on conduction and radiation for heat transfer should not be lower than 40.38 degrees C and 52.15 degrees C, respectively. To maintain thermal comfort, air outlet temperature should not be lower than 34.56 degrees C for convection type heaters. Our results provide technical and experimental basis for designing energy-saving buildings.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Effects of local heating on thermal comfort of standing people in extremely cold environments
    Deng, Yue
    Cao, Bin
    Liu, Bin
    Zhu, Yingxin
    BUILDING AND ENVIRONMENT, 2020, 185
  • [2] Field study of occupant comfort and office thermal environments in a cold climate
    Donnini, Giovanna
    Lai, Dorothy H.C.
    Laflamme, Michel
    Molina, Jean
    Lai, Ho K.
    Nguyen, Van H.
    Martello, Carlo
    Chang, Ching Y.
    Haghighat, Fariborz
    ASHRAE Transactions, 1997, 103 (pt 2): : 205 - 220
  • [3] Identification of local thermal conditions for sleeping comfort improvement in neutral to cold indoor thermal environments
    Song, Cong
    Liu, Yanfeng
    Zhou, Xiaojun
    Wang, Dengjia
    Wang, Yingying
    Liu, Jiaping
    JOURNAL OF THERMAL BIOLOGY, 2020, 87
  • [4] Field study on occupant comfort and residence thermal environments in a cold, dry climate
    Wang, ZJ
    Wang, G
    Lian, LM
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1697 - 1704
  • [5] Experimental study on local floor heating mats to improve thermal comfort of workers in cold environments
    Wang, Haiying
    Li, Wenyu
    Wang, Jie
    Xu, Manshu
    Ge, Baowei
    BUILDING AND ENVIRONMENT, 2021, 205
  • [6] Occupant behavioral adjustments and thermal comfort with torso and/or foot warming in two cold indoor environments
    Wang, Faming
    Ke, Ying
    Zheng, Qing
    Han, Xin 'ge
    Su, Wei
    Zhang, Xiang
    Lei, Tze-Huan
    Sun, Zhou
    Zhou, Haiyan
    Yang, Bin
    BUILDING AND ENVIRONMENT, 2024, 257
  • [7] A field study of occupant thermal comfort and thermal environments with radiant slab cooling
    Tian, Zhen
    Love, James A.
    BUILDING AND ENVIRONMENT, 2008, 43 (10) : 1658 - 1670
  • [8] Field survey on occupant thermal comfort of cold regions in transition season
    Qu Wan-ying
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 1620 - 1624
  • [9] The influence of occupant control behaviour on thermal comfort under different heating charging modes in residential buildings in cold regions
    Yan, Haiyan
    Xie, Linxiao
    Chow, David
    Chen, Xu
    Li, Meng
    HELIYON, 2024, 10 (16)
  • [10] Local Thermal Comfort and Physiological Responses in Uniform Environments
    Zhong, Xianzhun
    Yu, Hang
    Tang, Yin
    Mao, Huice
    Zhang, Kege
    BUILDINGS, 2024, 14 (01)