Analysis of Aperture-based Complexity Metrics and Their Effect on Patient-specific Quality Assurance in Intensity-modulated Radiation Therapy Planning

被引:0
|
作者
Saroj, Dinesh Kumar [1 ,2 ]
Yadav, Suresh [3 ]
Paliwal, Neetu [2 ]
Shende, Ravindra Bhagwat [1 ]
Gupta, Gaurav [1 ]
机构
[1] BALCO Med Ctr, Unit Vedanta Med Res Fdn, Dept Radiotherapy, New Raipur 493661, Chhattisgarh, India
[2] Rabindranath Tagore Univ, Dept Phys, Raisen, Madhya Pradesh, India
[3] Gandhi Med Coll, Dept Radiat Oncol, Bhopal, Madhya Pradesh, India
关键词
Gamma passing rate; intensity-modulated radiation therapy; modulation complexity score; patient-specific quality assurance; receiver operating characteristic curve; IMRT;
D O I
10.4103/jmp.jmp_195_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background:Identifying plans at risk of patient-specific quality assurance (PSQA) failure through complexity metrics can reduce the workload while maintaining quality. This study evaluates complexity metrics as predictors of PSQA outcomes.Materials and Methods:A retrospective analysis was conducted on 192 IMRT plans for head-and-neck cancer. Complexity metrics were calculated using an in-house Python program. PSQA was performed with 3%/2-mm gamma passing rate (GPR) criteria, with plans classified as "Pass" (GPR >= 95%) or "Fail." Statistical analyses, including Spearman's correlation and receiver operating characteristic analysis, assessed the metrics' predictive value.Results:Passing plans had an average GPR of 98.64 +/- 1.33%, compared to 92.17 +/- 2.35% for failing plans. The mean small area segment (MSAS) 5mm metric, with a threshold of 0.085, achieved a true positive rate of 38.17% and a false positive rate of 3.1%. Beam modulation and beam area indices also significantly differed between passing and failing plans.Conclusion:MSAS5 and edge metrics showed strong potential for identifying high-risk plans. These metrics can guide targeted PSQA, improving workflow efficiency without compromising treatment safety.
引用
收藏
页码:46 / 54
页数:9
相关论文
共 50 条
  • [11] Analysis of measurement deviations for the patient-specific quality assurance using intensity-modulated spot-scanning particle beams
    Li, Yongqiang
    Hsi, Wen C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (07) : 2675 - 2693
  • [12] Development and Evaluation of Multipurpose Phantom for Delivery Quality Assurance of Intensity-modulated Radiation Therapy
    Jang, Jae-Uk
    Han, Man-Seok
    Kim, Ki-Hwan
    Jeon, Min-Cheol
    Hwang, Ui-Jung
    JOURNAL OF MAGNETICS, 2022, 27 (04) : 430 - 439
  • [13] The evolution of quality assurance for intensity-modulated radiation therapy (IMRT): Sequential tomotherapy
    Woo, SY
    Grant, W
    McGary, JE
    Teh, BS
    Butler, EB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 274 - 286
  • [14] Analysis of dose comparison techniques for patient-specific quality assurance in radiation therapy
    Yu, Liting
    Tang, Timothy L. S.
    Cassim, Naasiha
    Livingstone, Alexander
    Cassidy, Darren
    Kairn, Tanya
    Crowe, Scott B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 189 - 198
  • [15] Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy
    Han, Ce
    Zhang, Ji
    Yu, Bing
    Zheng, Haoze
    Wu, Yibo
    Lin, Zhixi
    Ning, Boda
    Yi, Jinling
    Xie, Congying
    Jin, Xiance
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [16] Sensitivity of Three Patient-Specific Quality Assurance Systems to MLC Aperture Errors With Volumetric Modulated Arc Therapy
    Hu, Jinyou
    Gu, Shaoxian
    Wang, Ningyu
    Cui, Fengjie
    Zhang, Shengyuan
    Yin, Chuou
    Cai, Yunzhu
    Gou, Chengjun
    Zou, Lian
    Wu, Zhangwen
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [17] Inverse Verification of the Dose Distribution for Intensity Modulated Radiation Therapy Patient-specific Quality Assurance Using Dynamic MLC Log Files
    Lee, Jeong-Woo
    Park, Jeong-Hoon
    Chung, Jin-Beom
    Park, Ji-Yeon
    Choe, Bo-Young
    Suh, Tae-Suk
    Lee, Doo-Hyun
    Hong, Semie
    Kang, Min-Young
    Choi, Kyoung-Sik
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1649 - 1656
  • [18] Forecasting model for qualitative prediction of the results of patient-specific quality assurance based on planning and complexity metrics and their interrelations. Pilot study
    Piotrowski, Tomasz
    Ryczkowski, Adam
    Kalendralis, Petros
    Adamczewski, Marcin
    Sadowski, Piotr
    Bajon, Barbara
    Kruszyna-Mochalska, Marta
    Jodda, Agata
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (03) : 318 - 328
  • [19] A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans
    Li, Guangjun
    Wu, Kui
    Peng, Guang
    Zhang, Yingjie
    Bai, Sen
    MEDICAL DOSIMETRY, 2014, 39 (04) : 309 - 313
  • [20] Improving intensity-modulated radiation therapy quality assurance by adopting statistical process control
    Cui, T.
    Peng, J-X
    Jin, X-L
    Chu, X-G
    Zhang, J.
    Cui, L-Z
    Xing, X-F
    CANCER RADIOTHERAPIE, 2022, 26 (03): : 427 - 432