摘要
The BM@N is the first experiment at the NICA accelerator complex, which aims to study relativistic heavy ion interactions in the energy region corresponding to high net baryon densities. For the purpose of charged particle identification in the BM@N, two time-of-flight systems TOF400 and TOF700 are used. After the first physics run at the experiment, a series of calibrations have been performed. The calibration methods are described in detail, as well as an estimation of the time and coordinate resolution of the systems.