The evolution and clinical impact of single-port transaxillary robotic thyroidectomy: a comprehensive review

被引:0
|
作者
Kim, Kwangsoon [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Surg, 222 Banpo Daero, Seoul 06591, South Korea
关键词
Robotic surgery; single-port robotic system (SP robotic system); trans-axillary; thyroidectomy; ENDOSCOPIC THYROIDECTOMY; SURGERY; CANCER;
D O I
10.21037/gs-24-409
中图分类号
R61 [外科手术学];
学科分类号
摘要
Single-port (SP) transaxillary robotic thyroidectomy represents a significant innovation in the field of endocrine surgery, offering a minimally invasive approach that combines oncological efficacy with enhanced cosmetic outcomes. The introduction of the SP robotic system has enabled surgeons to perform thyroidectomy and lateral neck dissection through a single axillary incision, resulting in a scarless neck and reduced postoperative morbidity. This review explores the current practices and surgical techniques associated with SP transaxillary robotic thyroidectomy, emphasizing the benefits of the SP robotic system over traditional multi-port and open approaches. The system's enhanced precision, due to its articulated instruments and high-definition three-dimensional visualization, allows for meticulous dissection, minimizing the risk of complications such as recurrent laryngeal nerve injury and hypocalcemia. The SP design simplifies the surgical process, reducing trauma to surrounding tissues and leading to faster recovery times and improved patient satisfaction. Clinical outcomes of the SP approach are promising, with studies indicating comparable oncological safety to conventional methods and superior cosmetic results. Patient satisfaction is notably high, particularly regarding the absence of visible neck scarring. However, the technique's adoption is limited by its steep learning curve and the high cost of the SP robotic system. This review also highlights the need for further long-term studies to fully assess the sustainability of the SP robotic system's benefits, especially in terms of oncological outcomes and cost-effectiveness. The potential of the SP transaxillary approach to become a standard option in thyroid surgery is discussed, alongside the importance of continued research and surgeon training to optimize its use. In conclusion, SP transaxillary robotic thyroidectomy offers a compelling alternative to traditional approaches, with the potential to significantly enhance patient outcomes and satisfaction in thyroid surgery.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 50 条
  • [1] The learning curve for single-port transaxillary robotic thyroidectomy (SP-TART): experience through initial 50 cases of lobectomy
    Park, Joonseon
    Kang, Il Ku
    Kim, Kwangsoon
    Bae, Ja Seong
    Kim, Jeong Soo
    UPDATES IN SURGERY, 2023, 75 (03) : 691 - 700
  • [2] The learning curve for single-port transaxillary robotic thyroidectomy (SP-TART): experience through initial 50 cases of lobectomy
    Joonseon Park
    ll Ku Kang
    Kwangsoon Kim
    Ja Seong Bae
    Jeong Soo Kim
    Updates in Surgery, 2023, 75 : 691 - 700
  • [3] Single-port transaxillary robotic thyroidectomy (START): 200-cases with two-step retraction method
    Kim, Jin Kyong
    Choi, Sun Hyung
    Choi, Soon Min
    Choi, Hye Ryeon
    Lee, Cho Rok
    Kang, Sang-Wook
    Jeong, Jong Ju
    Nam, Kee-Hyun
    Chung, Woong Youn
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (04): : 2688 - 2696
  • [4] Robotic thyroidectomy using gas-insufflation one-step single-port transaxillary (GOSTA) approach
    Da Young Yu
    Young Woo Chang
    Dohoe Ku
    Seung Yeon Ko
    Hye Yoon Lee
    Gil Soo Son
    Surgical Endoscopy, 2023, 37 (11) : 8861 - 8870
  • [5] Robotic thyroidectomy using gas-insufflation one-step single-port transaxillary (GOSTA) approach
    Yu, Da Young
    Chang, Young Woo
    Ku, Dohoe
    Ko, Seung Yeon
    Lee, Hye Yoon
    Son, Gil Soo
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (11): : 8861 - 8870
  • [6] Comprehensive application of robotic retroauricular thyroidectomy: The evolution of robotic thyroidectomy
    Byeon, Hyung Kwon
    Kim, Da Hee
    Chang, Jae Won
    Ban, Myung Jin
    Park, Jae Hong
    Kim, Won Shik
    Choi, Eun Chang
    Koh, Yoon Woo
    LARYNGOSCOPE, 2016, 126 (08) : 1952 - 1957
  • [7] First Experience of Single-Port Robotic Areolar Approach Thyroidectomy
    Choi, Yun Suk
    Choi, Ji Hyun
    Jeon, Mi Sook
    Yu, Min Jung
    Lee, Hye Mi
    Shin, Ae Young
    Yi, Jin Wook
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2023, 16 (03) : 275 - 281
  • [8] Systematic Review and Meta-Analysis of Transaxillary Robotic Thyroidectomy Versus Open Thyroidectomy
    Shen, Hongliang
    Shan, Chengxiang
    Qiu, Ming
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2014, 24 (03) : 199 - 206
  • [9] Impact of body mass index on robotic transaxillary thyroidectomy
    Yap, Zeng
    Kim, Won Woong
    Kang, Sang-Wook
    Lee, Cho Rok
    Lee, Jandee
    Jeong, Jong Ju
    Nam, Kee-Hyun
    Chung, Woong Youn
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Single-port unilateral transaxillary totally endoscopic thyroidectomy: A survival animal and cadaver feasibility study
    Phillips, Henrique Neubarth
    Alvim Fiorelli, Rossano Kepler
    Queiroz, Marcelo Rios
    Oliveira, Andre Lacerda
    Zorron, Ricardo
    JOURNAL OF MINIMAL ACCESS SURGERY, 2016, 12 (01) : 63 - 67