Coreless Optical Fiber Surface Plasmon Resonance Refractive Index Sensor Enhanced by Ti3C2-MXene Sensitization

被引:0
作者
Chen, Yue [1 ]
Luo, Binbin [1 ]
Huang, Yao [1 ]
Liu, Yan [1 ]
Shi, Shenghui [1 ]
Zhao, Mingfu [1 ]
Yuan, Peiling [1 ]
Wu, Shengxi [1 ]
机构
[1] Chongqing Univ Technol, Chongqing Key Lab Opt Fiber Sensor & Photoelect De, Chongqing 400054, Peoples R China
关键词
optic sensing; coreless optical fiber; surface plasmon resonance; refractive index; Ti3C2-MXene; SENSITIVITY ENHANCEMENT; SPR SENSOR; CONFIGURATION; MXENES;
D O I
10.3788/AOS241533
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Objective Optical fiber surface plasmon resonance (SPR) sensors combine the advantages of optical fiber technology and SPR effect, offering small size, high sensitivity, fast response, and anti-electromagnetic interference capabilities. These features make them widely studied in biological sensing, chemical sensing, and environmental monitoring. However, when applied to biomolecular detection, further enhancement in refractive index sensitivity is still required. With advances in materials science, various two-dimensional (2D) nanomaterials, such as graphene and black phosphorus, have been increasingly used to improve the performance of biosensors. MXene, a relatively new member of the 2D nanomaterials family, is expressed as Mn+1XnTx(n=1-4), where "M" is a transition metal, "X" is C or N, and "T" represents surface terminations such as -O, -F, or -OH groups. Due to its excellent optical response, tunable band gap, and electronic properties, MXene holds promise for enhancing the performance of coreless optical fiber SPR sensors. In this paper, we focus on leveraging Ti3C2-MXene to improve refractive index sensitivity, making the sensors more suitable for applications requiring high sensitivity, such as biological sensing. Methods The proposed sensor adopts a multimode-coreless-multimode (MCM) fiber structure. Using COMSOL software, simulations are conducted to optimize the gold film thickness, coreless fiber length, and Ti3C2-MXene layer thickness. The simulation results reveal the optimal parameters: a 10 mm coreless fiber length, a 50 nm thick gold film sputtered on the fiber surface, and three layers of Ti3C2-MXene coating. The fabrication process involves attaching a negligible-thickness Ti3C2-MXene layer to the coreless fiber to fix the gold film, sputtering a thin gold layer to excite the SPR effect, and subsequently applying the Ti3C2-MXene coating to further enhance the SPR effect. The refractive index sensitivity is assessed by immersing the sensor in NaCl solutions with varying refractive indexes and recording the corresponding resonance wavelength. Results and Discussions The surface morphology of the gold film and Ti3C2-MXene coatings is characterized using field emission scanning electron microscopy (FESEM, ZEISS SIGMA HD) (Fig. 5). Energy spectrum analysis confirms the effective fixation of Ti3C2-MXene on the sensor surface (Fig. 6). The experimental results demonstrate that introducing Ti3C2-MXene significantly enhances the sensor's refractive index sensitivity. Without the MXene layer, the refractive index sensitivity is 2326.42 nm/RIU within the refractive index range of 1.3330 to 1.3660. After applying three layers of Ti3C2-MXene, the sensitivity increases to 4361.04 nm/RIU, representing an 87.5% improvement. A comparison of experimental results with theoretical predictions shows high consistency, validating the sensor's performance. However, the study also highlights that while the MXene layer improves sensitivity, it broadens spectral bandwidth, reducing the sensor's quality factor. Table 1 compares the performance of the proposed MCM fiber SPR sensor with other fiber-based SPR sensors, showing that the Ti3C2-MXene and MMF-CLF-MMF combination achieves superior sensitivity (4361.04 nm/RIU) and an enhancement (87.5%) exceeding other designs. In addition, the MCM fiber structure avoids mechanical strength reduction associated with grinding sensors into D-shapes or etching their cladding. Conclusions In this paper, we propose an MCM fiber SPR sensor utilizing the sensitization effects of Ti3C2-MXene. The principle of refractive index sensing and the influence of structural parameters are analyzed through simulations and experiments. The optimal sensor parameters are determined as a 50 nm gold film, 10 mm CLF fiber length, and three layers of Ti3C2-MXene. The experimental results indicate that within the refractive index range of 1.3330?1.3660, the refractive index sensitivity of the sensor increases from 2326.42 to 4361.04 nm/RIU, an 87.5% improvement compared to that of the MCM fiber SPR sensor without Ti3C2-MXene. The proposed MCM fiber SPR sensor offers a simple structure, low fabrication difficulty, reduced cost, and high sensitivity, making it promising for biological detection applications.
引用
收藏
页数:10
相关论文
共 34 条
  • [21] 25th Anniversary Article: MXenes: A New Family of Two-Dimensional Materials
    Naguib, Michael
    Mochalin, Vadym N.
    Barsoum, Michel W.
    Gogotsi, Yury
    [J]. ADVANCED MATERIALS, 2014, 26 (07) : 992 - 1005
  • [22] Sensitivity enhancement using silicon-black phosphorus-TDMC coated surface plasmon resonance biosensor
    Pal, Sarika
    Verma, Alka
    Saini, Jai Prakash
    Prajapati, Yogendra Kumar
    [J]. IET OPTOELECTRONICS, 2019, 13 (04) : 196 - 201
  • [23] 2D-antimonene-based surface plasmon resonance sensor for improvement of sensitivity
    Raikwar, Surjeet
    Srivastava, D. K.
    Saini, J. P.
    Prajapati, Y. K.
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2021, 127 (02):
  • [24] Two-Dimensional Ti3C2TX MXene Nanosheets for Efficient Copper Removal from Water
    Shahzad, Asif
    Rasool, Kashif
    Miran, Waheed
    Nawaz, Mohsin
    Jang, Jiseon
    Mahmoud, Khaled A.
    Lee, Dae Sung
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2017, 5 (12): : 11481 - 11488
  • [25] A surface plasmon resonance haemoglobin concentration sensor based on D-type optical fibre with a graphene-gold surface architecture
    Shi, Zhen-Jiang
    Guo, Shi-Liang
    Li, Xin
    Li, Wen-Chao
    Li, Zhi-Quan
    [J]. IET OPTOELECTRONICS, 2023, 17 (05) : 195 - 201
  • [26] Highly sensitive dual-core symmetrical side-polished modified D-shaped SPR based PCF refractive index sensor with deeply etched micro openings
    Singh, Shivam
    Prajapati, Y. K.
    [J]. OPTIK, 2021, 235
  • [27] A novel SPR sensor sensitivity-enhancing method for immunoassay by inserting MoS2 nanosheets between metal film and fiber
    Song, Hang
    Wang, Qi
    Zhao, Wan-Ming
    [J]. OPTICS AND LASERS IN ENGINEERING, 2020, 132
  • [28] Sensitive and selective surface plasmon resonance sensor employing a gold-supported graphene composite film/D-shaped fiber for dopamine detection
    Sun, Junxia
    Jiang, Shouzhen
    Xu, Jihua
    Li, Zhen
    Li, Chonghui
    Jing, Yu
    Zhao, Xiaofei
    Pan, Jie
    Zhang, Chao
    Man, Baoyuan
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2019, 52 (19)
  • [29] Optical Fiber Seawater Temperature and Salinity Sensor Based on Surface Plasmon Resonance
    Tong, Ruijie
    Yu, Wang
    Bin, Xing
    Yong, Zhao
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (11)
  • [30] Sensitivity Improvement of Bimetallic Layer-Based SPR Biosensor Using ZnO and Black Phosphorus
    Wang, Shutao
    Zhang, Jinqing
    Liu, Na
    Wan, Jincong
    [J]. PLASMONICS, 2023, 18 (05) : 1873 - 1883