SAR Radiometric Cross-Calibration Based on Multiple Pseudoinvariant Calibration Sites With Extensive Backscattering Coefficient Range

被引:0
|
作者
Zhou, Yongsheng [1 ]
Chen, Xiang [1 ]
Yin, Qiang [1 ]
Ma, Fei [1 ]
Zhang, Fan [1 ,2 ]
机构
[1] Beijing Univ Chem Technol, Coll Informat Sci & Technol, Beijing 100029, Peoples R China
[2] Beijing Univ Chem Technol, Interdisciplinary Res Ctr Artificial Intelligence, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Calibration; Backscatter; Optical sensors; Radar; Microwave radiometry; Accuracy; Windows; Radar cross-sections; Remote sensing; Reliability; Incidence angle correction; radiometric cross-calibration; synthetic aperture radar (SAR); weighted least squares regression; C-BAND; SCATTEROMETER; STABILITY;
D O I
10.1109/JSTARS.2025.3525461
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Synthetic aperture radar (SAR) radiometric cross-calibration achieves the calibration of uncalibrated satellites by employing calibrated satellites to illuminate the same ground targets. The stability of these ground targets is critical for effective cross-calibration. Such stable ground targets, named pseudoinvariant calibration sites (PICSs), have been extensively researched for optical sensors, but there has been comparatively less focus on SAR sensors. Furthermore, studies that synthesize multiple targets for comprehensive dynamic range calibration remain relatively unexplored. This article proposes an optimized method for selecting PICS for SAR radiometric cross-calibration to address these issues. This method incorporates spatial variation coefficients, spatial autocorrelation indicators, and edge extraction techniques to identify homogeneous targets. In addition, the backscattering coefficient's time-series root mean square error (RMSE) is leveraged to identify stable targets. Using time-series data from Sentinel-1, the study identifies 57 stable homogeneous targets as PICS, exhibiting a wide intensity distribution and a time-series RMSE less than 0.5 dB. Based on these PICS, this article further develops a wide dynamic range cross-calibration method based on multiple PICS sites. It employs weighted least squares regression for the different data quality of each site. The cross-calibration experiments demonstrate an average improvement in the accuracy of 0.82 dB compared to the cross-calibration method utilizing a single PICS site.
引用
收藏
页码:4836 / 4849
页数:14
相关论文
共 41 条
  • [31] Combining RadCalNet Sites for Radiometric Cross Calibration of Landsat 9 and Landsat 8 Operational Land Imagers (OLIs)
    Voskanian, Norvik
    Thome, Kurtis
    Wenny, Brian N.
    Tahersima, Mohammad H.
    Yarahmadi, Mehran
    REMOTE SENSING, 2023, 15 (24)
  • [32] Cross-calibration of the RapidEye Multispectral Imager payloads using near simultaneous acquisitions of pseudo-invariant test sites
    Thiele, Michael
    Anderson, Cody
    Brunn, Andreas
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XVIII, 2014, 9241
  • [33] Radiometric Cross-Calibration of GF-4/VNIR Sensor With Landsat8/OLI, Sentinel-2/MSI, and Terra/MODIS for Monitoring Its Degradation
    Gao, Caixia
    Liu, Yaokai
    Qiu, Shi
    Li, Chuanrong
    Ma, Lingling
    Han, Qijin
    Liu, Jingru
    Zhao, Enyu
    Zhao, Yongguang
    Qian, Yonggang
    Wang, Ning
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2020, 13 : 2337 - 2350
  • [34] Radiometric Cross Calibration of HY-1C/COCTS Based on Sentinel-3/OLCI
    Xie, Yong
    Feng, Duo
    Shao, Wen
    Han, Jie
    Chen, Yidan
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2024, 17 : 10422 - 10431
  • [35] Time Series Analysis-Based Long-Term Onboard Radiometric Calibration Coefficient Correction and Validation for the HY-1C Satellite Calibration Spectrometer
    Song, Qingjun
    Ma, Chaofei
    Liu, Jianqiang
    Wang, Xiaoxu
    Huang, Yu
    Lin, Guanyu
    Li, Zhanfeng
    REMOTE SENSING, 2022, 14 (19)
  • [36] Radiometric cross-calibration of Gaofen-1 WFV cameras using Landsat-8 OLI images: A solution for large view angle associated problems
    Feng, Lian
    Li, Juan
    Gong, Weishu
    Zhao, Xi
    Chen, Xiaoling
    Pang, Xiaoping
    REMOTE SENSING OF ENVIRONMENT, 2016, 174 : 56 - 68
  • [37] Radiometric Cross-Calibration of EO-1 ALI With L7 ETM+ and Terra MODIS Sensors Using Near-Simultaneous Desert Observations
    Chander, Gyanesh
    Angal, Amit
    Choi, Taeyoung
    Xiong, Xiaoxiong
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2013, 6 (02) : 386 - 399
  • [38] Cross-calibration of GF-1 WFV and SJ-9A PMS sensors based on homogeneous land surface targets
    Han, Q. (cresda_hanjin@126.com), 1600, Chinese Optical Society (34):
  • [39] Radiometric Cross-Calibration of Wide-Field-of-View Cameras Based on Gaofen-1/6 Satellite Synergistic Observations Using Landsat-8 Operational Land Imager Images: A Solution for Off-Nadir Wide-Field-of-View Associated Problems
    Dong, Jiadan
    Chen, Yepei
    Chen, Xiaoling
    Xu, Qiangqiang
    REMOTE SENSING, 2023, 15 (15)
  • [40] Multichannel HRWS SAR Imaging Based on Range-Variant Channel Calibration and Multi-Doppler-Direction Restriction Ambiguity Suppression
    Zhang, Shuang-Xi
    Xing, Meng-Dao
    Xia, Xiang-Gen
    Zhang, Lei
    Guo, Rui
    Liao, Yi
    Bao, Zheng
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2014, 52 (07): : 4306 - 4327