SAR Radiometric Cross-Calibration Based on Multiple Pseudoinvariant Calibration Sites With Extensive Backscattering Coefficient Range

被引:0
|
作者
Zhou, Yongsheng [1 ]
Chen, Xiang [1 ]
Yin, Qiang [1 ]
Ma, Fei [1 ]
Zhang, Fan [1 ,2 ]
机构
[1] Beijing Univ Chem Technol, Coll Informat Sci & Technol, Beijing 100029, Peoples R China
[2] Beijing Univ Chem Technol, Interdisciplinary Res Ctr Artificial Intelligence, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Calibration; Backscatter; Optical sensors; Radar; Microwave radiometry; Accuracy; Windows; Radar cross-sections; Remote sensing; Reliability; Incidence angle correction; radiometric cross-calibration; synthetic aperture radar (SAR); weighted least squares regression; C-BAND; SCATTEROMETER; STABILITY;
D O I
10.1109/JSTARS.2025.3525461
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Synthetic aperture radar (SAR) radiometric cross-calibration achieves the calibration of uncalibrated satellites by employing calibrated satellites to illuminate the same ground targets. The stability of these ground targets is critical for effective cross-calibration. Such stable ground targets, named pseudoinvariant calibration sites (PICSs), have been extensively researched for optical sensors, but there has been comparatively less focus on SAR sensors. Furthermore, studies that synthesize multiple targets for comprehensive dynamic range calibration remain relatively unexplored. This article proposes an optimized method for selecting PICS for SAR radiometric cross-calibration to address these issues. This method incorporates spatial variation coefficients, spatial autocorrelation indicators, and edge extraction techniques to identify homogeneous targets. In addition, the backscattering coefficient's time-series root mean square error (RMSE) is leveraged to identify stable targets. Using time-series data from Sentinel-1, the study identifies 57 stable homogeneous targets as PICS, exhibiting a wide intensity distribution and a time-series RMSE less than 0.5 dB. Based on these PICS, this article further develops a wide dynamic range cross-calibration method based on multiple PICS sites. It employs weighted least squares regression for the different data quality of each site. The cross-calibration experiments demonstrate an average improvement in the accuracy of 0.82 dB compared to the cross-calibration method utilizing a single PICS site.
引用
收藏
页码:4836 / 4849
页数:14
相关论文
共 41 条
  • [21] Cross-Calibration of iDXA and pQCT Scanners at Rural and Urban Research Sites in The Gambia, West Africa
    Breasail, Micheal O.
    Janha, Ramatoulie
    Zengin, Ayse
    Pearse, Camille
    Jarjou, Landing
    Prentice, Ann
    Ward, Kate A.
    CALCIFIED TISSUE INTERNATIONAL, 2023, 112 (05) : 573 - 583
  • [22] China Radiometric Calibration Sites Ground-based Automatic Observing Systems for CAL/VAL
    Zhang, Yong
    Li, Xin
    Rong, Zhiguo
    Zhang, Lijun
    Hu, Xiuqing
    Ba, Xiutian
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XIX, 2015, 9639
  • [23] Synthetic Aperture Radar Radiometric Cross Calibration Based on Distributed Targets
    Zhou, Yongsheng
    Zhuang, Li
    Duan, Jitong
    Zhang, Fan
    Hong, Wen
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2022, 15 : 9599 - 9612
  • [24] CROSS-CALIBRATION OF THE RAPIDEYE MULTISPECTRAL IMAGER PAYLOADS USING PSEUDO-INVARIANT TEST SITES
    Thiele, Michael
    Anderson, Cody
    Brunn, Andreas
    XXII ISPRS CONGRESS, TECHNICAL COMMISSION I, 2012, 39-B1 : 167 - 171
  • [25] An Automatic Radiometric Cross-Calibration Method for Wide-Angle Medium-Resolution Multispectral Satellite Sensor Using Landsat Data
    Lu, Jun
    He, Tao
    Liang, Shunlin
    Zhang, Yongjun
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [26] SAR Radiometric Calibration Based on Differential Geometry: From Theory to Experimentation on SAOCOM Imagery
    Imperatore, Pasquale
    Di Martino, Gerardo
    REMOTE SENSING, 2023, 15 (05)
  • [27] Radiometric Cross-calibration of ZY3 Satellite with GF1 PMS/WFV and Landsat-8 OLI
    Tang, Hongzhao
    Xie, Junfeng
    Tang, Xinming
    Li, Qi
    2019 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2019), 2019, : 9006 - 9009
  • [28] Phase Mismatch Calibration of the Multichannel SAR Based on Azimuth Cross Correlation
    Feng, Jin
    Gao, Canguan
    Zhang, Yi
    Wang, Robert
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2013, 10 (04) : 903 - 907
  • [29] Cross-calibration between beta and gamma sources using quartz OSL: Consequences of the use of the SAR protocol in optical dating
    Guerin, Gilles
    Valladas, Helene
    RADIATION MEASUREMENTS, 2014, 68 : 31 - 37
  • [30] An operational radiometric calibration procedure for the Landsat sensors based on pseudo-invariant target sites
    de Vries, C.
    Danaher, T.
    Denham, R.
    Scarth, P.
    Phinn, S.
    REMOTE SENSING OF ENVIRONMENT, 2007, 107 (03) : 414 - 429