CT radiomics based model for differentiating malignant and benign small (≤20mm) solid pulmonary nodules

被引:0
|
作者
Sun, Jing-Xi [1 ]
Zhou, Xuan-Xuan [1 ]
Yu, Yan-Jin [1 ]
Wei, Ya-Ming [2 ]
Shi, Yi-Bing [1 ]
Xu, Qing-Song [3 ]
Chen, Shuang-Shuang [4 ]
机构
[1] Xuzhou Cent Hosp, Dept Radiol, Xuzhou, Peoples R China
[2] Xuzhou Cent Hosp, Dept Informat, Xuzhou, Peoples R China
[3] Dept Hosp Off, Xuzhou Cent Hosp, Xuzhou, Peoples R China
[4] Xuzhou Cent Hosp, Dept Taishan Community Serv Ctr, Xuzhou, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2025年 / 15卷
关键词
CT; radiomics; pulmonary nodule; small; prediction; BIOPSY;
D O I
10.3389/fonc.2025.1502932
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Currently, the computed tomography (CT) radiomics-based models, which can evaluate small (<= 20 mm) solid pulmonary nodules (SPNs) are lacking. This study aimed to develop a CT radiomics-based model that can differentiate between benign and malignant small SPNs. Methods This study included patients with small SPNs between January 2019 and November 2021. The participants were then randomly categorized into training and testing cohorts with an 8:2 ratio. CT images of all the patients were analyzed to extract radiomics features. Furthermore, a radiomics scoring model was developed based on the features selected in the training group via univariate and multivariate logistic regression analyses. The testing cohort was then used to validate the developed predictive model. Results This study included 210 patients, 168 in the training and 42 in the testing cohorts. Radiomics scores were ultimately calculated based on 9 selected CT radiomics features. Furthermore, traditional CT and clinical risk factors associated with SPNs included lobulation (P < 0.001), spiculation (P < 0.001), and a larger diameter (P < 0.001). The developed CT radiomics scoring model comprised of the following formula: X = -6.773 + 12.0705xradiomics score+2.5313xlobulation (present: 1; no present: 0)+3.1761xspiculation (present: 1; no present: 0)+0.3253xdiameter. The area under the curve (AUC) values of the CT radiomics-based model, CT radiomics score, and clinicoradiological score were 0.957, 0.945, and 0.853, respectively, in the training cohort, while that of the testing cohort were 0.943, 0.916, and 0.816, respectively. Conclusions The CT radiomics-based model designed in the present study offers valuable diagnostic accuracy in distinguishing benign and malignant SPNs.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The value of radiomics based on dual-energy CT for differentiating benign from malignant solitary pulmonary nodules
    Liang, Gao
    Yu, Wei
    Liu, Shu-Qin
    Xie, Ming-Guo
    Liu, Min
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [2] The value of radiomics based on dual-energy CT for differentiating benign from malignant solitary pulmonary nodules
    Gao Liang
    Wei Yu
    Shu-qin Liu
    Ming-guo Xie
    Min Liu
    BMC Medical Imaging, 22
  • [3] A combined non-enhanced CT radiomics and clinical variable machine learning model for differentiating benign and malignant sub-centimeter pulmonary solid nodules
    Lin, Rui-Yu
    Zheng, Yi-Neng
    Lv, Fa-Jin
    Fu, Bin-Jie
    Li, Wang-Jia
    Liang, Zhang-Rui
    Chu, Zhi-Gang
    MEDICAL PHYSICS, 2023, 50 (05) : 2835 - 2843
  • [4] Multiclassifier fusion based on radiomics features for the prediction of benign and malignant primary pulmonary solid nodules
    Shen, Yao
    Xu, Fangyi
    Zhu, Wenchao
    Hu, Hongjie
    Chen, Ting
    Li, Qiang
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (05)
  • [5] The scoring system combined with radiomics and imaging features in predicting the malignant potential of incidental indeterminate small (<20 mm) solid pulmonary nodules
    Qu, Bai-Qiang
    Wang, Yun
    Pan, Yue-Peng
    Cao, Pei-Wei
    Deng, Xue-Ying
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [6] MRI-Based Clinical-Imaging-Radiomics Nomogram Model for Discriminating Between Benign and Malignant Solid Pulmonary Nodules or Masses
    Xie, Kexin
    Cui, Can
    Li, Xiaoqing
    Yuan, Yongfeng
    Wang, Zhongqiu
    Zeng, Liang
    ACADEMIC RADIOLOGY, 2024, 31 (10) : 4231 - 4241
  • [7] The effectiveness of deep learning model in differentiating benign and malignant pulmonary nodules on spiral CT
    Liu, Dongquan
    Zhao, Yonggang
    Liu, Bangquan
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (06) : 5129 - 5140
  • [8] Diagnostic value of PET/CT in differentiating benign from malignant solitary pulmonary nodules
    Dalli, A.
    Sen, H. Selimoglu
    Coskunsel, M.
    Komek, H.
    Abakay, O.
    Sergi, C.
    Tanrikulu, A. Cetin
    JOURNAL OF BUON, 2013, 18 (04): : 935 - 941
  • [9] Application Potential of Radiomics based on the Unenhanced CT Image for the Identification of Benign or Malignant Pulmonary Nodules
    Zhang, Ling
    Zeng, Bingliang
    Liu, Jiaqi
    Lin, Huashan
    Lei, Pinggui
    Fan, Bing
    Xu, Rong
    CURRENT MEDICAL IMAGING, 2024, 20
  • [10] Spectral CT-based radiomics signature for distinguishing malignant pulmonary nodules from benign
    Xu, Hang
    Zhu, Na
    Yue, Yong
    Guo, Yan
    Wen, Qingyun
    Gao, Lu
    Hou, Yang
    Shang, Jin
    BMC CANCER, 2023, 23 (01)