Image Quality in Adaptive Optics Optical Coherence Tomography of Diabetic Patients

被引:0
作者
Brunner, Elisabeth [1 ]
Kunze, Laura [2 ]
Drexler, Wolfgang [1 ]
Pollreisz, Andreas [2 ]
Pircher, Michael [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Ophthalmol & Optometry, Waehringer Guertel 18-20, A-1090 Vienna, Austria
基金
奥地利科学基金会;
关键词
adaptive optics; optical coherence tomography; image quality; diabetic retinopathy; FIELD-OF-VIEW; GANGLION-CELLS; HUMAN RETINA; HIGH-SPEED; PHOTORECEPTORS; VISUALIZATION; SLO/OCT; HEALTHY; PUPIL; OCT;
D O I
10.3390/diagnostics15040429
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: An assessment of the retinal image quality in adaptive optics optical coherence tomography (AO-OCT) is challenging. Many factors influence AO-OCT imaging performance, leading to greatly varying imaging results, even in the same subject. The aim of this study is to introduce quantitative means for an assessment of AO-OCT image quality and to compare these with parameters retrieved from the pyramid wavefront sensor of the system. Methods: We used a spectral domain AO-OCT instrument to repetitively image six patients suffering from diabetic retinopathy over a time span of one year. The data evaluation consists of two volume acquisitions with a focus on the photoreceptor layer, each at five different retinal locations per visit; 7-8 visits per patient are included in this data analysis, resulting in a total of similar to 420 volumes. Results: A large variability in AO-OCT image quality is observed between subjects and between visits of the same subject. On average, the image quality does not depend on the measurement location. The data show a moderate correlation between the axial position of the volume recording and image quality. The correlation between pupil size and AO-OCT image quality is not linear. A weak correlation is found between the signal-to-noise ratio of the wavefront sensor image and the image quality. Conclusions: The introduced AO-OCT image quality metric gives useful insights into the performance of such a system. A longitudinal assessment of this metric, together with wavefront sensor data, is essential to identify factors influencing image quality and, in the next step, to optimize the performance of AO-OCT systems.
引用
收藏
页数:14
相关论文
共 32 条
[1]   Characteristics of the human isoplanatic patch and implications for adaptive optics retinal imaging [J].
Bedggood, Phillip ;
Daaboul, Mary ;
Ashman, Ross ;
Smith, George ;
Metha, Andrew .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (02)
[2]   Quantifying image quality in AOSLO images of photoreceptors [J].
Brennan, Brea D. ;
Heitkotter, Heather ;
Carroll, Joseph ;
Tarima, Sergey ;
Cooper, Robert F. .
BIOMEDICAL OPTICS EXPRESS, 2024, 15 (05) :2849-2862
[3]   Improvements on speed, stability and field of view in adaptive optics OCT for anterior retinal imaging using a pyramid wavefront sensor [J].
Brunner, Elisabeth ;
Kunze, Laura ;
Laidlaw, Victoria ;
Jodlbauer, Daniel ;
Drexler, Wolfgang ;
Ramlau, Ronny ;
Pollreisz, Andreas ;
Pircher, Michael .
BIOMEDICAL OPTICS EXPRESS, 2024, 15 (10) :6098-6116
[4]   Retinal adaptive optics imaging with a pyramid wavefront sensor [J].
Brunner, Elisabeth ;
Shatokhina, Julia ;
Shirazi, Muhammad Faizan ;
Drexler, Wolfgang ;
Leitgeb, Rainer ;
Pollreisz, Andreas ;
Hitzenberger, Christoph K. ;
Ramlau, Ronny ;
Pircher, Michael .
BIOMEDICAL OPTICS EXPRESS, 2021, 12 (10) :5969-5990
[5]   Extended-period AOSLO imaging in the living human retina without pupil dilation: a feasibility study [J].
Cui, Jiahe ;
Villamil, Maria ;
Schneider, Allie C. ;
Lawton, Penelope F. ;
Young, Laura K. ;
Booth, Martin J. ;
Smithson, Hannah E. .
BIOMEDICAL OPTICS EXPRESS, 2024, 15 (09) :4995-5008
[6]   Adaptive optics optical coherence tomography in glaucoma [J].
Dong, Zachary M. ;
Wollstein, Gadi ;
Wang, Bo ;
Schuman, Joel S. .
PROGRESS IN RETINAL AND EYE RESEARCH, 2017, 57 :76-88
[7]   Adaptive optics SLO/OCT for 3D imaging of human photoreceptors in vivo [J].
Felberer, Franz ;
Kroisamer, Julia-Sophie ;
Baumann, Bernhard ;
Zotter, Stefan ;
Schmidt-Erfurth, Ursula ;
Hitzenberger, Christoph K. ;
Pircher, Michael .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (02) :439-456
[8]   A Review of Adaptive Optics Optical Coherence Tomography: Technical Advances, Scientific Applications, and the Future [J].
Jonnal, Ravi S. ;
Kocaoglu, Omer P. ;
Zawadzki, Robert J. ;
Liu, Zhuolin ;
Miller, Donald T. ;
Werner, John S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) :OCT51-OCT68
[9]   THREE-DIMENSIONAL ANALYSIS OF RETINAL MICROANEURYSMS WITH ADAPTIVE OPTICS OPTICAL COHERENCE TOMOGRAPHY [J].
Karst, Sonja G. ;
Salas, Matthias ;
Hafner, Julia ;
Scholda, Christoph ;
Vogl, Wolf-Dieter ;
Drexler, Wolfgang ;
Pircher, Michael ;
Schmidt-Erfurth, Ursula .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (03) :465-472
[10]   Increasing the field of view of adaptive optics scanning laser ophthalmoscopy [J].
Laslandes, Marie ;
Salas, Matthias ;
Hitzenberger, Christoph K. ;
Pircher, Michael .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (11) :4811-4826