Pregnancy-Related Cardiovascular Diseases: A Radiological Overview

被引:0
作者
Lauriero, Francesco [1 ]
Mazza, Giulia [2 ]
Perazzolo, Alessio [2 ]
Ottoni, Giacomo [2 ]
Cipriani, Alessia [2 ]
Pereira, Jose F. Castro [3 ]
Marano, Riccardo [1 ,2 ]
Natale, Luigi [1 ,2 ]
机构
[1] Fdn Policlin Univ Agostino Gemelli IRCCS, Dept Diagnost Imaging Oncol Radiotherapy & Hematol, Largo Agostino Gemelli 8, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dept Radiol & Haematol Sci, Sect Radiol, I-00168 Rome, Italy
[3] Unidade Local Saude Almada Seixal EPE, Dept Radiol, P-2805267 Almada, Portugal
关键词
pregnancy; cardiovascular diseases; pulmonary embolism; aortic dissection; spontaneous coronary artery dissection; peripartum cardiomyopathy; magnetic resonance imaging (MRI); computed tomography (CT); CORONARY-ARTERY DISSECTION; EMBOLISM DIAGNOSTIC-ACCURACY; CT PULMONARY ANGIOGRAPHY; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; AORTIC DISSECTION; PERIPARTUM CARDIOMYOPATHY; CONTRAST MATERIAL; EUROPEAN-SOCIETY; MR-ANGIOGRAPHY;
D O I
10.3390/jcdd12020043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pregnancy induces significant hemodynamic changes, and cardiovascular diseases (CVDs) are one of the leading causes of non-obstetric maternal morbidity and mortality during pregnancy or the postpartum period in developed countries. The effective diagnosis and management of CVDs in pregnant women require a thorough evaluation that considers the health of both the mother and the fetus. Imaging plays a pivotal role in this evaluation, offering essential insights into the most significant pregnancy-related CVDs. However, due to concerns about fetal exposure, the use of contrast agents and radiation exposure must be carefully managed. Following to the principle of "As Low As Reasonably Achievable" (ALARA), strategies to minimize these risks are crucial for ensuring patient safety while maintaining diagnostic accuracy. This review highlights the contribution of cardiovascular imaging techniques, particularly computed tomography (CT) and magnetic resonance imaging (MRI), in the assessment of common pregnancy-related CVDs, and outlines strategies to reduce radiation exposure and limit contrast agent use when feasible, aiming to increase radiologists' awareness of this crucial topic.
引用
收藏
页数:22
相关论文
共 113 条
[21]   Peripartum Cardiomyopathy is Associated With Abnormalities of Myocardial Deformation and Late Gadolinium Enhancement [J].
Du Plessis, Jacques ;
Gujrathi, Rahul ;
Hassanin, Magdi ;
Mckee, Hayley ;
Hanneman, Kate ;
Karur, Gauri Rani ;
Chan, Victor ;
Warnica, Will ;
Wald, Rachel M. ;
Nguyen, Elsie T. .
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2025, 76 (01) :153-160
[22]   Pregnancy-associated cardiomyopathy - Clinical characteristics and a comparison between early and late presentation [J].
Elkayam, U ;
Akhter, MW ;
Singh, H ;
Khan, S ;
Bitar, F ;
Hameed, A ;
Shotan, A .
CIRCULATION, 2005, 111 (16) :2050-2055
[23]   Pregnancy-Associated Acute Myocardial Infarction A Review of Contemporary Experience in 150 Cases Between 2006 and 2011 [J].
Elkayam, Uri ;
Jalnapurkar, Sawan ;
Barakkat, Mohamad N. ;
Khatri, Nudrat ;
Kealey, Angela J. ;
Mehra, Anil ;
Roth, Arie .
CIRCULATION, 2014, 129 (16) :1695-1702
[24]   Peripartum cardiomyopathy: a systematic literature review [J].
Ersboll, Anne S. ;
Damm, Peter ;
Gustafsson, Finn ;
Vejlstrup, Niels G. ;
Johansen, Marianne .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2016, 95 (11) :1205-1219
[25]  
ESUR Contrast Media Safety Committee, 2018, ESUR guidelines on contrast safety
[26]   Computed Tomography Angiography of the Aorta-Optimization of Automatic Tube Voltage Selection Settings to Reduce Radiation Dose or Contrast Medium in a Prospective Randomized Trial [J].
Euler, Andre ;
Taslimi, Tilo ;
Eberhard, Matthias ;
Kobe, Adrian ;
Reeve, Kelly ;
Zimmermann, Alexander ;
Krauss, Andreas ;
Gutjahr, Ralf ;
Schmidt, Bernhard ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2021, 56 (05) :283-291
[27]   Imaging modalities for the early diagnosis of acute aortic syndrome [J].
Evangelista, Artur ;
Carro, Amelia ;
Moral, Sergio ;
Teixido-Tura, Gisela ;
Rodriguez-Palomares, Jose F. ;
Cuellar, Hug ;
Garcia-Dorado, David .
NATURE REVIEWS CARDIOLOGY, 2013, 10 (08) :477-486
[28]   Prospective Study of Low-Radiation and Low-Iodine Dose Aortic CT Angiography in Obese and Non-Obese Patients: Image Quality and Impact of Patient Characteristics [J].
Fink, Matthias A. ;
Stoll, Sibylle ;
Melzig, Claudius ;
Steuwe, Andrea ;
Partovi, Sasan ;
Boeckler, Dittmar ;
Kauczor, Hans-Ulrich ;
Rengier, Fabian .
DIAGNOSTICS, 2022, 12 (03)
[29]   Diagnostic accuracy of true fast imaging with steady-state precession, MR pulmonary angiography and volume-interpolated body examination for pulmonary embolism compared with CT pulmonary angiography [J].
Fu, Qing ;
Cheng, Qiguang ;
Kong, Xiangchuang ;
Ma, Hui ;
Lei, Ziqiao .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2021, 21 (01)
[30]   Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality [J].
Gill, Maninderpal Kaur ;
Vijayananthan, Anushya ;
Kumar, Gnana ;
Jayarani, Kasthoori ;
Ng, Kwan-Hoong ;
Sun, Zhonghua .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2015, 5 (04) :524-533