Internal adaptation assessment of implant infrastructures manufactured through five different techniques (heat-press, milling, lost wax, calcinable cylinder, and CAD/Waxx®): an in vitro pilot study

被引:0
|
作者
Sartori, Regis [1 ]
Fernandes, Juliana Campos Hasse [2 ]
Fernandes, Gustavo Vicentis Oliveira [2 ]
Joly, Julio Cesar [1 ]
机构
[1] Fac Sao Leopoldo Mand, Dept Implantol & Periodontol, Campinas, Brazil
[2] AT Still Univ, Missouri Sch Dent & Oral Hlth, St Louis, MO 63501 USA
来源
FRONTIERS IN DENTAL MEDICINE | 2024年 / 5卷
关键词
dental marginal adaptation; dental prosthesis; dental porcelain; CAD/CAM; prosthetic abutment; ALL-CERAMIC CROWNS; MARGINAL FIT; ZIRCONIA; METAL; FRAMEWORKS; ABUTMENTS; COPINGS; SUCCESS; SYSTEMS;
D O I
10.3389/fdmed.2024.1483177
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate the fit performance of implant infrastructures manufactured by five different techniques: heat-press (IPS), milling (ZIR), lost wax (CER), calcinable cylinder (CAL), and CAD/Waxx (R) (CAD). Methods: The methodology was based on the Replica Technique, which can simulate and evaluate the fit of the infrastructure on the implant component. Thus, each infrastructure was internally filled with low-viscosity silicone addition and seated on the component until its final setting, obtaining the replica of the cementation space. After removing the coping containing the silicone film, light-density silicone was inserted addition in place of the components, and in its surroundings, condensation silicone was applied, establishing support for the assembly. The joint was sectioned mesiodistally, photographed, and analyzed in image processing software in order to measure the thickness of the interface infrastructure/implant at five different areas: marginal opening (M), gingival-axial angle (G-A), axial region (A), axial-occlusal angle (A-O) and occlusal surface (O). Results: The lowest and the highest average thickness between groups was, respectively, IPS: 187.5 mu m and CAD: 221.6 mu m, with statistically significant differences (p < 0.01) among all five groups; the lowest and the highest average of all groups in each point was, respectively, A: 99.86 mu m and O: 279.78 mu m. The IPS group exhibited the lowest value of the internal space of the infrastructure on the implant. The marginal region of all groups demonstrated a correlation with the findings in the literature, except the CAL group; otherwise, the occlusal region and the angles A-O and G-A exhibited values beyond that expected. Discussion: It was possible to conclude that the five infrastructure groups presented different adaptations, suggesting possible interference in the internal spaces due to the manufacturing infrastructure processes.
引用
收藏
页数:12
相关论文
empty
未找到相关数据