Performance Evaluation of the LabGenius C-CT/NG-BMX Assay for Chlamydia trachomatis and Neisseria gonorrhoeae Detection

被引:0
|
作者
Lim, Yong Kwan [1 ,2 ]
Kweon, Oh Joo [1 ,3 ]
Park, Ae Ja [4 ]
Kim, Hongkyung [1 ,2 ]
Yoon, Sumi [1 ,3 ]
Kim, Tae-Hyoung [5 ]
Lee, Mi-Kyung [1 ,2 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[2] Chung Ang Univ Hosp, Dept Lab Med, 102 Heukseok Ro, Seoul 06973, South Korea
[3] Chung Ang Univ, Gwangmyeong Hosp, Dept Lab Med, Gwangmyeong, South Korea
[4] BIOMEDUX Co, Suwon, South Korea
[5] Chung Ang Univ, Coll Med, Dept Urol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Chlamydia trachomatis; Diagnostic tests; Evaluation; Neisseria gonorrhoeae; PCR; Sexually transmitted pathogens;
D O I
10.3343/alm.2024.0118
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The LabGenius C-CT/NG-BMX assay (LabGenius CT/NG; BIOMEDUX, Gyeonggi, Republic of Korea) is a recently developed real-time PCR assay that can simultaneously detect the sexually transmitted pathogens Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) in genitourinary specimens. We evaluated the analytical performance of this assay in comparison with BD MAX CT/GC/TV (Becton Dickinson, Franklin Lakes, NJ, USA). The results of both assays were in nearly perfect agreement for the detection of CT and NG. LabGenius CT/NG demonstrated acceptable analytical performance, comparable with that of another commercially available kit, and provides a cost-effective option for detectingsexuallytrans- mitted pathogens in routine and follow-up testing.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 34 条
  • [21] Evaluation of a dilution method for non-evaluable results in the detection of Chlamydia trachomatis and Neisseria gonorrhoeae with the Cobas 4800 platform
    Parra-Sanchez, Manuel
    Garcia-Rey, Silvia
    Zakariya-Yousef Breval, Ismail
    Sierra-Atienza, Celestina
    Bernal-Martinez, Samuel
    Carlos Palomares-Folia, Jose
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2017, 35 (06): : 364 - 366
  • [22] Value of repeat testing using Cepheid GeneXpert CT/NG for indeterminate PCR results when diagnosing Chlamydia trachomatis and Neisseria gonorrhoeae
    Parcell, Benjamin J.
    Ratnayake, Lasantha
    Kaminski, Geraldine
    Olver, William J.
    Yirrell, David L.
    INTERNATIONAL JOURNAL OF STD & AIDS, 2015, 26 (01) : 65 - 67
  • [23] Review of use of a new rapid real-time PCR, the Cepheid GeneXpert® (Xpert) CT/NG assay, for Chlamydia trachomatis and Neisseria gonorrhoeae: results for patients while in a clinical setting
    Gaydos, Charlotte A.
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2014, 14 (02) : 135 - 137
  • [24] Is confirmatory testing of Roche cobas 4800 CT/NG test Neisseria gonorrhoeae positive samples required? Comparison of the Roche cobas 4800 CT/NG test with an opa/pap duplex assay for the detection of N gonorrhoeae
    Perry, Michael D.
    Jones, Rachel N.
    Corden, Sally A.
    SEXUALLY TRANSMITTED INFECTIONS, 2014, 90 (04) : 303 - 308
  • [25] Analytical and clinical validation of a multiplex PCR assay for detection of Neisseria gonorrhoeae and Chlamydia trachomatis including simultaneous LGV serotyping on an automated high-throughput PCR system
    Pflueger, Lisa Sophie
    Noerz, Dominik
    Grunwald, Moritz
    Pfefferle, Susanne
    Giersch, Katja
    Christner, Martin
    Weber, Beatrice
    Aepfelbacher, Martin
    Rohde, Holger
    Luetgehetmann, Marc
    MICROBIOLOGY SPECTRUM, 2024, 12 (03):
  • [26] Performance assessment of the Allplex™ STI Essential real-time PCR assay for the diagnosis of Neisseria gonorrhoeae and Chlamydia trachomatis infections in genital and extra-genital sites
    Robinet, Sylvain
    Parisot, Francois
    JOURNAL OF LABORATORY MEDICINE, 2019, 43 (04) : 191 - 200
  • [27] Evaluation of the Abbott RealTime™ CT assay with the BD ProbeTec™ ET assay for the detection of Chlamydia trachomatis in a clinical microbiology laboratory
    Walsh, Anne
    Rourke, Fiona O.
    Lao, Bairbre Ni
    Crowley, Brendan
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 64 (01) : 13 - 19
  • [28] Comparison of an in-house real-time duplex PCR assay with commercial HOLOGIC® APTIMA assays for the detection of Neisseria gonorrhoeae and Chlamydia trachomatis in urine and extra-genital specimens
    Venter, Johanna M. E.
    Mahlangu, Precious M.
    Mueller, Etienne E.
    Lewis, David A.
    Rebe, Kevin
    Struthers, Helen
    McIntyre, James
    Kularatne, Ranmini S.
    BMC INFECTIOUS DISEASES, 2019, 19 (1)
  • [29] Molecular detection and confirmation of Neisseria gonorrhoeae in urogenital and extragenital specimens using the Abbott CT/NG RealTime assay and an in-house assay targeting the porA pseudogene
    A. Walsh
    F. O. Rourke
    B. Crowley
    European Journal of Clinical Microbiology & Infectious Diseases, 2011, 30 : 561 - 567
  • [30] Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in pharyngeal and rectal specimens using the BD Probetec ET system, the Gen-Probe Aptima Combo 2 assay and culture
    Ota, K. V.
    Tamari, I. E.
    Smieja, M.
    Jamieson, F.
    Jones, K. E.
    Towns, L.
    Juzkiw, J.
    Richardson, S. E.
    SEXUALLY TRANSMITTED INFECTIONS, 2009, 85 (03) : 182 - 186