An electrochemical sensor based on electrodeposited methylene blue on a carbon nanotube decorated hydrogel for the detection of ascorbic acid

被引:0
|
作者
Tang, Linghui [1 ]
Huang, Yufeng [2 ]
Qian, Zhihuan [1 ]
Zhao, Jifan [1 ]
Hasebe, Yasushi [3 ]
Dong, Yan [1 ]
Wang, Yue [1 ]
机构
[1] Univ Sci & Technol Liaoning, Sch Chem Engn, 189 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
[2] Univ Sci & Technol Liaoning, Sch Int Educ, 189 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
[3] Saitama Inst Technol, Fac Engn, Dept Life Sci & Green Chem, 1690 Fusaiji, Saitama 3690293, Japan
关键词
PASTE ELECTRODE; GRAPHENE OXIDE; URIC-ACID; NANOCOMPOSITE; DOPAMINE;
D O I
10.1039/d4ay01827c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a self-assembled electrochemical sensor was prepared by coating with a carbon nanotube (CNT) decorated hydrogel (HG) combined with electrodeposition of methylene blue (MB), and then used for the detection of ascorbic acid (AA). The three-dimensional network of HG has the advantages of large electroactive surface area, rapid diffusion and electron transfer rate, strong adhesive ability and stabilization of the polymerized MB. The MB provides high electrocatalytic activity and works as an electron transfer mediator to facilitate the oxidation of AA. The successful synthesis of the hydrogel and the preparation of the sensor are confirmed by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The layer-by-layer assembly was identified by AFM with the heights of 22.1 nm and 186.8 nm for the hydrogel and MB layers, respectively. Under the optimal conditions, the sensor has a linear range of 0.1 mM to 10 mM and a detection limit of 0.05 mM. What's more, the prepared sensor also exhibits good stability (current retention of 91.22% after 100 cycles for testing 0.25 mM AA), excellent anti-interference ability, good reproducibility (RSD of 4.26% for five independent experiments), excellent operational stability (RSD of 1.66% for 30 consecutive AA additions), fast response time (<4 s) and shows satisfactory results in the detection of AA in vitamin C tablets.
引用
收藏
页码:714 / 723
页数:10
相关论文
共 50 条
  • [31] Methylene blue immobilized on cellulose acetate with titanium dioxide: an application as sensor for ascorbic acid
    Hoffmann, Andrea A.
    Dias, Silvio L. P.
    Rodrigues, Jordana R.
    Pavan, Flavio A.
    Benvenutti, Edilson V.
    Lima, Eder C.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2008, 19 (05) : 943 - 949
  • [32] A novel electrochemical sensor based on CuBTC metal–organic framework decorated with carbon nanotube for highly sensitive detection of enrofloxacin in water samples
    Doan, Tien Dat
    Tran, Thi Thao
    Nguyen, Thu Hang
    Nguyen, Manh B.
    Nguyen, Hoang Anh
    Ba, Viet Anh Pham
    Vu, Thi Thu Ha
    Nguyen, Thi Kim Thuong
    Hoang, Mai Ha
    Pham, Thi Hai Yen
    Journal of Applied Electrochemistry, 2024,
  • [33] Screen Printed Electrochemical Sensor for Ascorbic Acid Detection Based on Nafion/Ionic Liquids/Graphene Composite on Carbon Electrodes
    Manurung, Robeth Viktoria
    Marakka, Mahadir
    Pide, Arifin
    Kurniawan, Erry Dwi
    Hermida, I. Dewa Putu
    2020 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET): FOSTERING INNOVATION THROUGH ICTS FOR SUSTAINABLE SMART SOCIETY, 2020, : 291 - 295
  • [34] Multi-walled carbon nanotube modified carbon paste electrode as an electrochemical sensor for the determination of epinephrine in the presence of ascorbic acid and uric acid
    Thomas, Tony
    Mascarenhas, Ronald J.
    Martis, Praveen
    Mekhalif, Zineb
    Swamy, B. E. Kumara
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (06): : 3294 - 3302
  • [35] Highly selective and sensitive sensor based on an organic electrochemical transistor for the detection of ascorbic acid
    Zhang, Lijun
    Wang, Guiheng
    Wu, Di
    Xiong, Can
    Zheng, Lei
    Ding, Yunsheng
    Lu, Hongbo
    Zhang, Guobing
    Qiu, Longzhen
    BIOSENSORS & BIOELECTRONICS, 2018, 100 : 235 - 241
  • [36] Preparation of Nanoporous Gold-based Electrochemical Sensor for the Detection of Ascorbic Acid in Drinks
    Zhang Q.
    Cheng W.
    Zhang Y.
    Yang W.
    Yang Y.
    Tang X.
    Shipin Kexue/Food Science, 2021, 42 (20): : 274 - 279
  • [37] An Electrochemical DNA-Prussian Blue-Carbon Paste Biosensor for the Detection of Ascorbic Acid in Pharmaceuticals
    Isaac, Rimal R. S.
    Nair, Manjusree U.
    Praseetha, P. K.
    2014 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES (ICCICCT), 2014, : 55 - 59
  • [38] Multiwalled carbon nanotube-based nanosensor for ultrasensitive detection of uric acid, dopamine, and ascorbic acid
    Savk, Aysun
    Ozdil, Buse
    Demirkan, Buse
    Nas, Mehmet Salih
    Calimli, Mehmet Harbi
    Alma, Mehmet Hakki
    Inamuddin
    Asiri, Abdullah M.
    Sen, Fatih
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 99 : 248 - 254
  • [39] Electrochemical Sensor Based on Carbon-Incorporated WSe2 Nanosheets for Simultaneous Detection of Ascorbic Acid, Dopamine, and Uric Acid
    Cogal, Sadik
    Bhethanabotla, Venkat R.
    IEEE SENSORS JOURNAL, 2022, 22 (15) : 14952 - 14958
  • [40] A Novel Electrochemical Sensor Based on Pd Confined Mesoporous Carbon Hollow Nanospheres for the Sensitive Detection of Ascorbic Acid, Dopamine, and Uric Acid
    Zhang, Wanqing
    Li, Xijiao
    Liu, Xiaoxue
    Song, Kaixuan
    Wang, Haiyang
    Wang, Jichao
    Li, Renlong
    Liu, Shanqin
    Peng, Zhikun
    MOLECULES, 2024, 29 (11):