An electrochemical sensor based on electrodeposited methylene blue on a carbon nanotube decorated hydrogel for the detection of ascorbic acid

被引:0
|
作者
Tang, Linghui [1 ]
Huang, Yufeng [2 ]
Qian, Zhihuan [1 ]
Zhao, Jifan [1 ]
Hasebe, Yasushi [3 ]
Dong, Yan [1 ]
Wang, Yue [1 ]
机构
[1] Univ Sci & Technol Liaoning, Sch Chem Engn, 189 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
[2] Univ Sci & Technol Liaoning, Sch Int Educ, 189 Qianshan Middle Rd, Anshan 114051, Liaoning, Peoples R China
[3] Saitama Inst Technol, Fac Engn, Dept Life Sci & Green Chem, 1690 Fusaiji, Saitama 3690293, Japan
关键词
PASTE ELECTRODE; GRAPHENE OXIDE; URIC-ACID; NANOCOMPOSITE; DOPAMINE;
D O I
10.1039/d4ay01827c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a self-assembled electrochemical sensor was prepared by coating with a carbon nanotube (CNT) decorated hydrogel (HG) combined with electrodeposition of methylene blue (MB), and then used for the detection of ascorbic acid (AA). The three-dimensional network of HG has the advantages of large electroactive surface area, rapid diffusion and electron transfer rate, strong adhesive ability and stabilization of the polymerized MB. The MB provides high electrocatalytic activity and works as an electron transfer mediator to facilitate the oxidation of AA. The successful synthesis of the hydrogel and the preparation of the sensor are confirmed by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The layer-by-layer assembly was identified by AFM with the heights of 22.1 nm and 186.8 nm for the hydrogel and MB layers, respectively. Under the optimal conditions, the sensor has a linear range of 0.1 mM to 10 mM and a detection limit of 0.05 mM. What's more, the prepared sensor also exhibits good stability (current retention of 91.22% after 100 cycles for testing 0.25 mM AA), excellent anti-interference ability, good reproducibility (RSD of 4.26% for five independent experiments), excellent operational stability (RSD of 1.66% for 30 consecutive AA additions), fast response time (<4 s) and shows satisfactory results in the detection of AA in vitamin C tablets.
引用
收藏
页码:714 / 723
页数:10
相关论文
共 50 条
  • [21] An electrochemical ascorbic acid sensor based on palladium nanoparticles supported on graphene oxide
    Wu, Geng-huang
    Wu, Yan-fang
    Liu, Xi-wei
    Rong, Ming-cong
    Chen, Xiao-mei
    Chen, Xi
    ANALYTICA CHIMICA ACTA, 2012, 745 : 33 - 37
  • [22] Electrochemical Sensor Based on Carbon Paste Modified by Cobalt(II) Porphyrin for Ascorbic Acid Determination
    Caldeira, Samuel de Almeida
    da Silva, Daniela Nunes
    Pereira, Arnaldo Cesar
    REVISTA VIRTUAL DE QUIMICA, 2022, 14 (02) : 115 - 122
  • [23] Electrodeposited Ni-Fe onto Glassy Carbon for the Detection of Methylene Blue
    Bahrololoomi, Arash
    Bilan, Hubert K.
    Podlaha, Elizabeth J.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (01)
  • [24] Electrochemical sensor based on Ni/reduced graphene oxide nanohybrids for selective detection of ascorbic acid
    Ren, Miao
    Kang, Xinyuan
    Li, Li
    Duan, Liping
    Liao, Fang
    JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2019, 40 (10) : 1516 - 1522
  • [25] PdPt bimetallic alloy nanowires-based electrochemical sensor for sensitive detection of ascorbic acid
    Jin, Lihua
    Zhang, Zaihua
    Zhuang, Zhihua
    Meng, Zheng
    Li, Cong
    Shen, Yehua
    RSC ADVANCES, 2016, 6 (48): : 42008 - 42013
  • [26] NiFe2O4 nanoparticles-decorated activated carbon nanocomposite based electrochemical sensor for selective detection of dopamine in presence of uric acid and ascorbic acid
    Aparna, T. K.
    Sivasubramanian, R.
    JOURNAL OF CHEMICAL SCIENCES, 2018, 130 (02)
  • [27] Carboxyl functionalized graphene oxide based electrochemical sensor for detection of dopamine in presence of ascorbic acid, uric acid and synthetic cerebrospinal fluid
    Bordoloi, Priyakshi
    Das, Diganta Kumar
    INDIAN JOURNAL OF CHEMISTRY, 2022, 61 (04): : 365 - 369
  • [28] Poly(sulfosalicylic acid)/multi-walled Carbon Nanotube Modified Electrode for the Electrochemical Detection of Catechol
    Liang, Yongqing
    Li, Jian
    Zhao, Yanjun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (10): : 9512 - 9522
  • [29] Self-assembled gold decorated polydopamine nanospheres as electrochemical sensor for simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan
    Arroquia, Andres
    Acosta, Irene
    Garcia Armada, M. Pilar
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 109
  • [30] A Novel Flexible Electrochemical Ascorbic Acid Sensor Constructed by Ferrocene Methanol doped Multi-walled Carbon Nanotube Yarn
    Wang, Yue
    Wu, Jinping
    Yang, Tian
    Wang, Zhong
    Hasebe, Yasushi
    Lv, Tianhang
    Zhang, Zhiqiang
    ELECTROANALYSIS, 2021, 33 (12) : 2445 - 2451