Comparison Between Attenuation Measurement and the Controlled Attenuation Parameter for the Assessment of Hepatic Steatosis Based on MRI Images

被引:0
作者
Gotoh, Tatsuya [1 ]
Kumada, Takashi [2 ]
Ogawa, Sadanobu [1 ]
Niwa, Fumihiko [1 ]
Toyoda, Hidenori [3 ]
Hirooka, Masashi [4 ]
Koizumi, Yohei [4 ]
Hiasa, Yoichi [4 ]
Akita, Tomoyuki [5 ]
Tanaka, Junko [5 ]
Shimizu, Masahito [6 ]
机构
[1] Ogaki Municipal Hosp, Dept Imaging Diag, Ogaki, Japan
[2] Gifu Kyoritsu Univ, Fac Nursing, Dept Nursing, Ogaki, Japan
[3] Ogaki Municipal Hosp, Dept Gastroenterol & Hepatol, Ogaki, Japan
[4] Ehime Univ, Dept Gastroenterol & Metabiol, Grad Sch Med, Matsuyama, Ehime, Japan
[5] Hiroshima Univ, Inst Biomed & Hlth Sci, Dept Epidemiol Infect Dis Control & Prevent, Hiroshima, Japan
[6] Gifu Univ, Grad Sch Med, Dept Gastroenterol Internal Med, Gifu, Japan
关键词
attenuation coefficient; attenuation measurement; Bland-Altman analysis; controlled attenuation parameter; hepatic steatosis; MRI-derived proton density fat fraction; FATTY LIVER-DISEASE; ULTRASOUND; AGREEMENT; FIBROSIS; CRITERIA;
D O I
10.1111/liv.16210
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: This study prospectively compared the diagnostic accuracies of the improved Attenuation Measurement (iATT) algorithm and the Controlled Attenuation Parameter (CAP) and assessed the interchangeability of iATT with magnetic resonance imaging-derived proton density fat fraction (MRI-derived PDFF). Methods: Patients with chronic liver disease were prospectively enrolled and underwent iATT, CAP and MRI-derived PDFF measurements for hepatic steatosis evaluation. According to MRI-derived PDFF values, steatosis grades were categorised as steatosis (S)0 (< 5.2%), S1 (>= 5.2%, < 11.3%), S2 (>= 11.3%, < 17.1%) and S3 (>= 17.1%). Correlation coefficients (CCs) were determined, diagnostic performances were compared by the area under the receiver operating characteristic curve (AUROC) and agreement was evaluated using the calculated percentage error (PE) and expected limit of agreement (LOA). Results: A total of 414 patients (median age 64 years, 203 females) were evaluated. The CC between iATT and MRI-derived PDFF was 0.727 (95% confidence interval [CI] 0.678-0.770), which was higher than that between CAP and MRI-derived PDFF at 0.615 (95% CI 0.551-0.672) (p < 0.001). The AUROCs of iATT for >= S1, >= S2 and >= S3 were 0.901 (95% CI 0.870-0.931), 0.878 (95% CI 0.846-0.910) and 0.839 (95% CI 0.794-0.883), respectively. The diagnostic performances of iATT for >= S1 and >= S2 showed significantly higher AUROCs than those of CAP (p < 0.001, p = 0.036, respectively). The calculated PE and the expected LOA for CAP and iATT were 38.94% and 22.66% and 32.94% and 30.03%, respectively. Conclusions: iATT was superior to CAP and comparable to MRI-derived PDFF in assessing hepatic steatosis.
引用
收藏
页数:12
相关论文
共 43 条
  • [1] Reporting of method comparison studies: a review of advice, an assessment of current practice, and specific suggestions for future reports
    Abu-Arafeh, A.
    Jordan, H.
    Drummond, G.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (05) : 569 - 575
  • [2] Magnetic Resonance Imaging Proton Density Fat Fraction Associates With Progression of Fibrosis in Patients With Nonalcoholic Fatty Liver Disease
    Ajmera, Veeral
    Park, Charlie C.
    Caussy, Cyrielle
    Singh, Seema
    Hernandez, Carolyn
    Bettencourt, Ricki
    Hooker, Jonathan
    Sy, Ethan
    Behling, Cynthia
    Xu, Ronghui
    Middleton, Michael S.
    Valasek, Mark A.
    Faulkner, Claire
    Rizo, Emily
    Richards, Lisa
    Sirlin, Claude B.
    Loomba, Rohit
    [J]. GASTROENTEROLOGY, 2018, 155 (02) : 307 - +
  • [3] A Comparative Study of Ultrasound Attenuation Imaging, Controlled Attenuation Parameters, and Magnetic Resonance Spectroscopy for the Detection of Hepatic Steatosis
    Bao, Jingwen
    Lv, Yueming
    Wang, Kun
    Wang, Quanwen
    Chen, Yanling
    Dong, Yi
    Zhu, Yuli
    Wang, Wenping
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (07) : 1481 - 1489
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Common Carotid Artery Volume Flow: A Comparison Study between Ultrasound Vector Flow Imaging and Phase Contrast Magnetic Resonance Imaging
    Brandt, Andreas Hjelm
    Olesen, Jacob Bjerring
    Moshavegh, Ramin
    Jensen, Jorgen Arendt
    Nielsen, Michael Bachmann
    Hansen, Kristoffer Lindskov
    [J]. NEUROLOGY INTERNATIONAL, 2021, 13 (03) : 269 - 278
  • [6] Brandt AH, 2018, DAN MED J, V65
  • [7] Prospective Comparison of Attenuation Imaging and Controlled Attenuation Parameter for Liver Steatosis Diagnosis in Patients With Nonalcoholic Fatty Liver Disease and Type 2 Diabetes
    Burgio, Marco Dioguardi
    Castera, Laurent
    Oufighou, Mehdi
    Rautou, Pierre-Emmanuel
    Paradis, Valerie
    Bedossa, Pierre
    Sartoris, Riccardo
    Ronot, Maxime
    Bodard, Sylvain
    Garteiser, Philippe
    Van Beers, Bernard
    Valla, Dominique
    Vilgrain, Valerie
    Correas, Jean Michel
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2024, 22 (05) : 1005 - 1013
  • [8] Metabolic Dysfunction-Associated Steatotic Liver Disease (MASLD): A State-of-the-Art Review
    Chan, Wah-Kheong
    Chuah, Kee-Huat
    Rajaram, Ruveena Bhavani
    Lim, Lee-Ling
    Ratnasingam, Jeyakantha
    Vethakkan, Shireene Ratna
    [J]. JOURNAL OF OBESITY & METABOLIC SYNDROME, 2023, 32 (03) : 197 - 213
  • [9] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [10] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845