Experimental investigation on the low temperature performance of a novel three-pressure air source heat pump

被引:0
作者
Bai, Jing [1 ]
Wang, Lejian [1 ]
Cui, Siqi [1 ]
Zheng, Huifan [1 ]
He, Siyuan [1 ]
Chen, Mingzhi [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou 450007, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-pressure; Air source heat pump; Heating; Defrosting; SYSTEMS; GROWTH;
D O I
10.1016/j.applthermaleng.2024.124628
中图分类号
O414.1 [热力学];
学科分类号
摘要
As people's demand for living comfort grows, the problems of conventional air source heat pumps (ASHPs) become more prominent in low-temperature and high-humidity environments: heating performance attenuation, low defrosting efficiency, and significant impact on indoor thermal comfort during defrosting. Existing literature usually focuses on only one or two of these issues, and few comprehensively cover them. Based on current literature, this paper proposes a novel multi-functional three-pressure ASHP that can cover the above three aspects with a series-parallel combination structure featuring dual compressors and dual cycles. This design enables switching multiple heating and defrosting modes through valve combination and improves performance through two-stage throttling and subcooling. An experimental platform is constructed to evaluate its operational performance. The experimental results show that: (1) In heating modes, the average heating capacity of the three-pressure cycle heating mode is 2897.15 W, and the average COP is 2.47, while these two data of the conventional cycle heating mode are 2393.65 W and 2.4, and the improvement rates of 20.4 % and 2.9 %, respectively. It also extends the high-efficiency heating period of the system, enables rapid heating at start-up, increases compressor suction and discharge pressure, and improvs system stability. (2) In defrosting modes, compared with the conventional defrosting cycle, the three-pressure defrosting cycle raises the condensation temperature faster, reduces the defrosting time from 448 s to 265 s (40.8 % shorter). The auxiliary defrosting cycle has little effect on indoor thermal comfort and less defrosting power consumption, with the power saving rate as high as 44.6 %. Overall, the novel three-pressure ASHP has a unique and innovative structure, significantly optimizing performance under low-temperature and frosting conditions and improving energy efficiency and comfort. The results of this study provide a new solution concept for the future development of ASHPs, offering significant reference value for further development and application.
引用
收藏
页数:13
相关论文
共 50 条
[21]   Investigation of annual energy performance of a VWV air source heat pump system [J].
Wang, R. Z. ;
Jin, Z. Q. ;
Zhai, X. Q. ;
Jin, C. C. ;
Luo, W. L. ;
Eikevik, T. M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 85 :383-394
[22]   Experimental investigation on a screw-type air source heat pump system with air heat absorption defrosting [J].
Jia, Jikang ;
Si, Pengfei ;
Rong, Xiangyang ;
Liu, Boran ;
Xiang, Bo ;
Shi, Lijun ;
Zhang, Min .
APPLIED THERMAL ENGINEERING, 2024, 241
[23]   Experimental investigation on the space heating performance of air source heat pump with vapor injection under frosting condition [J].
Wei, Wenzhe ;
Feng, Zhenglei ;
Sun, Yuying ;
Wang, Wei ;
Jin, Xinyue ;
Zhang, Jianfei ;
Dai, Chuanmin .
JOURNAL OF BUILDING ENGINEERING, 2024, 90
[24]   Performance investigation on an air source heat pump system with latent heat thermal energy storage [J].
Lin, Ying ;
Fan, Yubin ;
Yu, Meng ;
Jiang, Long ;
Zhang, Xuejun .
ENERGY, 2022, 239
[25]   Performance analysis of a novel air source hybrid solar assisted heat pump [J].
Cai, Jingyong ;
Li, Zhouhang ;
Ji, Jie ;
Zhou, Fan .
RENEWABLE ENERGY, 2019, 139 :1133-1145
[26]   Evaluation of the coefficient of performance of an air source heat pump unit and an air to water heat pump [J].
Tangwe, S. ;
Kusakana, K. .
JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2021, 32 (01) :27-40
[27]   Performance analysis of air source heat pump according to outside temperature and relative humidity with mathematical modeling [J].
Sezen, Kutbay ;
Gungor, Afsin .
ENERGY CONVERSION AND MANAGEMENT, 2022, 263
[28]   Dynamic character investigation and optimization of a novel air-source heat pump system [J].
Wang, Zhihua ;
Wang, Fenghao ;
Wang, Xinke ;
Ma, Zhenjun ;
Wu, Xiaozhou ;
Song, Mengjie .
APPLIED THERMAL ENGINEERING, 2017, 111 :122-133
[29]   Experimental study of an air-source heat pump for simultaneous heating and cooling - Part 1: Basic concepts and performance verification [J].
Byrne, Paul ;
Miriel, Jacques ;
Lenat, Yves .
APPLIED ENERGY, 2011, 88 (05) :1841-1847
[30]   Investigation on the efficiency degradation characterization of low ambient temperature air source heat pump under partial load operation [J].
Xu, Zhaowei ;
Li, Hao ;
Xu, Wei ;
Shao, Shuangquan ;
Wang, Zhichao ;
Gou, Xiaoxi ;
Zhao, Mingyang ;
Li, Jiandong .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 :99-110