Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative Study

被引:0
|
作者
Ivanovic, Aleksandra [1 ,2 ,3 ]
Cheng, Jeffrey Tao [4 ]
Schmeltz, Margaux [3 ]
Wimmer, Wilhelm [1 ,6 ]
Schlepuetz, Christian M. [3 ]
Remenschneider, Aaron K. [4 ,5 ]
Bonnin, Anne [3 ]
Anschuetz, Lukas [1 ,7 ,8 ,9 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Inselspital, Freiburgstr, CH-3010 Bern, Switzerland
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Hearing Res Lab, Murtenstr 50, CH-3008 Bern, Switzerland
[3] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
[4] Harvard Med Sch, Eaton Peabody Labs, Massachusetts Eye & Ear, Boston, MA 02114 USA
[5] Harvard Med Sch, Boston Childrens Hosp, Dept Otolaryngol Head & Neck Surg, Boston, MA 02115 USA
[6] Klinikum Rechts Der Isar, TUM Sch Med, Dept Otorhinolaryngol, Munich, Germany
[7] CHUV Ctr Hosp Univ Vaudois, Dept Otorhinolaryngol Head & Neck Surg, Lausanne, Switzerland
[8] Univ Lausanne, Lausanne, Switzerland
[9] Sense Innovat & Res Ctr, Lausanne, Switzerland
关键词
Middle ear; Laser Doppler vibrometry; Dynamic synchrotron-based X-ray microtomography; Phase-contrast; HUMAN MIDDLE-EAR; TYMPANIC MEMBRANE; FREQUENCY; VIBRATION; RECONSTRUCTION; TRANSMISSION; MOTION; CAT;
D O I
10.1007/s10162-024-00971-0
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeThere are challenges in understanding the biomechanics of the human middle ear, and established methods for studying this system show significant limitations. In this study, we evaluate a novel dynamic imaging technique based on synchrotron X-ray microtomography designed to assess the biomechanical properties of the human middle ear by comparing it to laser-Doppler vibrometry (LDV).MethodsWe examined three fresh-frozen temporal bones (TB), two donated by white males and one by a Black female, using dynamic synchrotron-based X-ray microtomography for 256 and 512 Hz, stimulated at 110 dB and 120 dB sound pressure level (SPL). In addition, we performed measurements on these TBs using 1D LDV, a well-established method.ResultsThe normalized displacement values (mu m/Pa) at the umbo and the posterior crus of the stapes are consistent or within 5-10 dB differences between all LDV and dynamic microtomography measurements and previously reported literature references. In general, the overall behavior is similar between the two measurement techniques.ConclusionIn conclusion, our results demonstrate the suitability of dynamic synchrotron-based X-ray microtomography in studying the middle ear's biomechanics. However, this study shows that better standardization regarding acoustic stimulation and measurement points is needed to better compare the two measurement techniques.
引用
收藏
页码:63 / 75
页数:13
相关论文
共 50 条
  • [41] X-ray spectra of neutron stars vs. black holes
    Tanaka, Y
    BLACK HOLES IN BINARIES AND GALACTIC NUCLEI: DIAGNOSTICS, DEMOGRAPHY AND FORMATION, 2001, : 141 - 148
  • [42] Beacons in the sky: Classical novae vs. X-ray bursts
    J. José
    M. Hernanz
    The European Physical Journal A - Hadrons and Nuclei, 2006, 27 : 107 - 115
  • [43] Optical vs. X-ray selection for finding clusters of galaxies
    Gilbank, DG
    Bower, RG
    Castander, RJ
    GAS AND GALAXY EVOLUTION: A CONFERENCE IN HONOR OF THE 20TH ANNIVERSARY OF THE VLA, 2001, 240 : 644 - 645
  • [44] Effects of infrared laser on the bone repair assessed by x-ray microtomography (μct) and histomorphometry
    Paolillo, Alessandra Rossi
    Paolillo, Fernando Rossi
    da Silva, Alessandro M. Hakme
    de Menezes Reiff, Rodrigo Bezerra
    Bagnato, Vanderlei Salvador
    Alves, Jose Marcos
    BIOPHOTONICS SOUTH AMERICA, 2015, 9531
  • [45] COMPARATIVE-STUDY OF X-RAY SOURCES CHARACTERIZING X-RAY INSTRUMENTATION
    LI, CK
    PETRASSO, RD
    WENZEL, KW
    LO, DH
    BORRAS, MC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 697 - 699
  • [47] Participant Perspectives on Pulse-Echo Ultrasound Technology vs. Dual Energy X-Ray Absorptiometry (DXA): A Comparative Study
    Algahtani, Abdulkareem
    Asiri, Mohammed
    Mokbel, Kinan
    Meertens, Robert
    Fulford, Jon
    Strain, William david
    Knapp, Karen
    IN VIVO, 2025, 39 (02): : 909 - 916
  • [48] Simulations of Dynamic Laser/Plasma X-Ray Production
    Miller, Craig L.
    Welch, Dale R.
    Rose, David V.
    Campbell, Robert B.
    Oliver, Bryan V.
    Webb, Timothy J.
    Flicker, Dawn G.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (10) : 2658 - 2666
  • [49] X-ray microtomography to study the microstructure of cream cheese-type products
    Laverse, J.
    Mastromatteo, M.
    Frisullo, P.
    Del Nobile, M. A.
    JOURNAL OF DAIRY SCIENCE, 2011, 94 (01) : 43 - 50
  • [50] A 3D study of mortar degradation by X-ray computed microtomography
    Bernard, D
    Chen, D
    Burlion, N
    COMPUTATIONAL METHODS IN MATERIALS CHARACTERISATION, 2004, 6 : 297 - 306