Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative Study

被引:0
|
作者
Ivanovic, Aleksandra [1 ,2 ,3 ]
Cheng, Jeffrey Tao [4 ]
Schmeltz, Margaux [3 ]
Wimmer, Wilhelm [1 ,6 ]
Schlepuetz, Christian M. [3 ]
Remenschneider, Aaron K. [4 ,5 ]
Bonnin, Anne [3 ]
Anschuetz, Lukas [1 ,7 ,8 ,9 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Inselspital, Freiburgstr, CH-3010 Bern, Switzerland
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Hearing Res Lab, Murtenstr 50, CH-3008 Bern, Switzerland
[3] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
[4] Harvard Med Sch, Eaton Peabody Labs, Massachusetts Eye & Ear, Boston, MA 02114 USA
[5] Harvard Med Sch, Boston Childrens Hosp, Dept Otolaryngol Head & Neck Surg, Boston, MA 02115 USA
[6] Klinikum Rechts Der Isar, TUM Sch Med, Dept Otorhinolaryngol, Munich, Germany
[7] CHUV Ctr Hosp Univ Vaudois, Dept Otorhinolaryngol Head & Neck Surg, Lausanne, Switzerland
[8] Univ Lausanne, Lausanne, Switzerland
[9] Sense Innovat & Res Ctr, Lausanne, Switzerland
关键词
Middle ear; Laser Doppler vibrometry; Dynamic synchrotron-based X-ray microtomography; Phase-contrast; HUMAN MIDDLE-EAR; TYMPANIC MEMBRANE; FREQUENCY; VIBRATION; RECONSTRUCTION; TRANSMISSION; MOTION; CAT;
D O I
10.1007/s10162-024-00971-0
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeThere are challenges in understanding the biomechanics of the human middle ear, and established methods for studying this system show significant limitations. In this study, we evaluate a novel dynamic imaging technique based on synchrotron X-ray microtomography designed to assess the biomechanical properties of the human middle ear by comparing it to laser-Doppler vibrometry (LDV).MethodsWe examined three fresh-frozen temporal bones (TB), two donated by white males and one by a Black female, using dynamic synchrotron-based X-ray microtomography for 256 and 512 Hz, stimulated at 110 dB and 120 dB sound pressure level (SPL). In addition, we performed measurements on these TBs using 1D LDV, a well-established method.ResultsThe normalized displacement values (mu m/Pa) at the umbo and the posterior crus of the stapes are consistent or within 5-10 dB differences between all LDV and dynamic microtomography measurements and previously reported literature references. In general, the overall behavior is similar between the two measurement techniques.ConclusionIn conclusion, our results demonstrate the suitability of dynamic synchrotron-based X-ray microtomography in studying the middle ear's biomechanics. However, this study shows that better standardization regarding acoustic stimulation and measurement points is needed to better compare the two measurement techniques.
引用
收藏
页码:63 / 75
页数:13
相关论文
共 50 条
  • [31] Study by X-ray microtomography of the horizontal vibration effects on sand densification
    Olmos, L.
    Chaix, J. -M.
    Nadler, S.
    Bonnefoy, O.
    Gelet, J. -L.
    Thomas, G.
    GRANULAR MATTER, 2016, 18 (03)
  • [32] Osteomyelitis in diabetic hoot syndrome (DFS).: Scintigraphy vs. MRI vs. X-ray vs. sonography.
    Thelen, MH
    Eschmann, SM
    Enderle, M
    Cörper, S
    Schweizer, HP
    Kopp, AF
    Pressler, H
    Meissner, C
    Bares, R
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 194P - 194P
  • [33] X-ray microtomography study of the compaction process of rods under tapping
    Fu, Yang
    Xi, Yan
    Cao, Yixin
    Wang, Yujie
    PHYSICAL REVIEW E, 2012, 85 (05):
  • [34] Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer
    Yamada, Shinya
    Axelsson, Magnus
    Ishisaki, Yoshitaka
    Konami, Saori
    Takemura, Nozomi
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Leutenegger, Maurice A.
    Porter, F. Scott
    Eckart, Megan E.
    Szymkowiak, Andrew
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 2019, 71 (04)
  • [35] Study by X-ray microtomography of the horizontal vibration effects on sand densification
    L. Olmos
    J.-M. Chaix
    S. Nadler
    O. Bonnefoy
    J.-L. Gelet
    G. Thomas
    Granular Matter, 2016, 18
  • [36] X-ray microtomography study of the spallation response in Ta-W
    McDonald, S. A.
    Cotton, M.
    Millett, J. C. F.
    Bourne, N. K.
    Withers, P. J.
    18TH APS-SCCM AND 24TH AIRAPT, PTS 1-19, 2014, 500
  • [37] X-ray Microtomography Study on the Cemented Structure of Cemented Granular Materials
    Qin, Wei
    Jin, Feng
    Yang, Siyuan
    Huang, Duruo
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2023, 21 (01) : 1 - 16
  • [38] COMPARISON OF MERCURY POROSIMETRY AND X-RAY MICROTOMOGRAPHY FOR POROSITY STUDY OF SANDSTONES
    Kovarova, Katerina
    Sevcik, Robert
    Weishauptova, Zuzana
    ACTA GEODYNAMICA ET GEOMATERIALIA, 2012, 9 (04): : 541 - 549
  • [39] A COMPARATIVE EVALUATION OF RING ARTIFACTS REDUCTION FILTERS FOR X-RAY COMPUTED MICROTOMOGRAPHY IMAGES
    Brun, F.
    Kourousias, G.
    Dreossi, D.
    Mancini, L.
    Tromba, G.
    2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011, : 405 - 408
  • [40] Beacons in the sky: Classical novae vs. X-ray bursts
    Jose, J.
    Hernanz, M.
    EUROPEAN PHYSICAL JOURNAL A, 2006, 27 (Suppl 1): : 107 - 115