Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative Study

被引:0
|
作者
Ivanovic, Aleksandra [1 ,2 ,3 ]
Cheng, Jeffrey Tao [4 ]
Schmeltz, Margaux [3 ]
Wimmer, Wilhelm [1 ,6 ]
Schlepuetz, Christian M. [3 ]
Remenschneider, Aaron K. [4 ,5 ]
Bonnin, Anne [3 ]
Anschuetz, Lukas [1 ,7 ,8 ,9 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Inselspital, Freiburgstr, CH-3010 Bern, Switzerland
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Hearing Res Lab, Murtenstr 50, CH-3008 Bern, Switzerland
[3] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
[4] Harvard Med Sch, Eaton Peabody Labs, Massachusetts Eye & Ear, Boston, MA 02114 USA
[5] Harvard Med Sch, Boston Childrens Hosp, Dept Otolaryngol Head & Neck Surg, Boston, MA 02115 USA
[6] Klinikum Rechts Der Isar, TUM Sch Med, Dept Otorhinolaryngol, Munich, Germany
[7] CHUV Ctr Hosp Univ Vaudois, Dept Otorhinolaryngol Head & Neck Surg, Lausanne, Switzerland
[8] Univ Lausanne, Lausanne, Switzerland
[9] Sense Innovat & Res Ctr, Lausanne, Switzerland
关键词
Middle ear; Laser Doppler vibrometry; Dynamic synchrotron-based X-ray microtomography; Phase-contrast; HUMAN MIDDLE-EAR; TYMPANIC MEMBRANE; FREQUENCY; VIBRATION; RECONSTRUCTION; TRANSMISSION; MOTION; CAT;
D O I
10.1007/s10162-024-00971-0
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeThere are challenges in understanding the biomechanics of the human middle ear, and established methods for studying this system show significant limitations. In this study, we evaluate a novel dynamic imaging technique based on synchrotron X-ray microtomography designed to assess the biomechanical properties of the human middle ear by comparing it to laser-Doppler vibrometry (LDV).MethodsWe examined three fresh-frozen temporal bones (TB), two donated by white males and one by a Black female, using dynamic synchrotron-based X-ray microtomography for 256 and 512 Hz, stimulated at 110 dB and 120 dB sound pressure level (SPL). In addition, we performed measurements on these TBs using 1D LDV, a well-established method.ResultsThe normalized displacement values (mu m/Pa) at the umbo and the posterior crus of the stapes are consistent or within 5-10 dB differences between all LDV and dynamic microtomography measurements and previously reported literature references. In general, the overall behavior is similar between the two measurement techniques.ConclusionIn conclusion, our results demonstrate the suitability of dynamic synchrotron-based X-ray microtomography in studying the middle ear's biomechanics. However, this study shows that better standardization regarding acoustic stimulation and measurement points is needed to better compare the two measurement techniques.
引用
收藏
页码:63 / 75
页数:13
相关论文
共 50 条
  • [21] Thermonuclear X-ray bursts: theory vs. observations
    Cumming, A
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2004, 132 : 435 - 445
  • [22] A comparative study of automatic thresholding approaches for 3D x-ray microtomography of trabecular bone
    Gomez, W.
    Sales, E.
    Lopes, R. T.
    Pereira, W. C. A.
    MEDICAL PHYSICS, 2013, 40 (09)
  • [23] Comparative effectiveness of lung cancer screening by computed tomography (CT) vs. chest x-ray (CXR) vs. no screening.
    Flores, John Paul
    Moreno-Koehler, Alejandro
    Finkelman, Matthew
    Caro, Jaime
    Strauss, Gary M.
    JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (15)
  • [24] Dynamic imaging of oil shale pyrolysis using synchrotron X-ray microtomography
    Saif, Tarik
    Lin, Qingyang
    Singh, Kamaljit
    Bijeljic, Branko
    Blunt, Martin J.
    GEOPHYSICAL RESEARCH LETTERS, 2016, 43 (13) : 6799 - 6807
  • [25] Quick x-ray microtomography using a laser-driven betatron source
    Dopp, A.
    Hehn, L.
    Goetzfried, J.
    Wenz, J.
    Gilljohann, M.
    Ding, H.
    Schindler, S.
    Pfeiffer, F.
    Karsch, S.
    OPTICA, 2018, 5 (02): : 199 - 203
  • [26] X-ray microtomography and laser ablation in the analysis of ink distribution in coated paper
    Myllys, M.
    Hakkanen, H.
    Korppi-Tommola, J.
    Backfolk, K.
    Sirvio, P.
    Timonen, J.
    JOURNAL OF APPLIED PHYSICS, 2015, 117 (14)
  • [27] Study of liquid gallium as a function of pressure and temperature using synchrotron x-ray microtomography and x-ray diffraction
    Li, Renfeng
    Li, Liangliang
    Yu, Tony
    Wang, Luhong
    Chen, Jiaxuan
    Wang, Yanbin
    Cai, Zhonghou
    Chen, Jiuhua
    Rivers, Mark L.
    Liu, Haozhe
    APPLIED PHYSICS LETTERS, 2014, 105 (04)
  • [28] Comparative effectiveness of a mnemonic-use approach vs. self-study to interpret a lateral chest X-ray
    Thompson, Michael
    Johansen, Dallin
    Stoner, Russell
    Jarstad, Allison
    Sorrells, Robert
    McCarroll, Michele L.
    Justice, Wade
    ADVANCES IN PHYSIOLOGY EDUCATION, 2017, 41 (04) : 518 - 521
  • [29] A COMPARATIVE STUDY OF ORGAN DOSES ASSESSMENT FOR PATIENTS UNDERGOING CONVENTIONAL X-RAY EXAMINATIONS: PHANTOM EXPERIMENTS VS. CALCULATIONS
    Golikov, V.
    Barkovsky, A.
    Wallstrom, E.
    Cederblad, A.
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (02) : 223 - 234
  • [30] Three-hump curve of laser x-ray emission vs. varied focusing conditions
    Ryc, L
    Krása, J
    Láska, L
    Parys, P
    Rohlena, K
    Skála, J
    PLASMA 2005, 2006, 812 : 299 - +