Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative Study

被引:0
|
作者
Ivanovic, Aleksandra [1 ,2 ,3 ]
Cheng, Jeffrey Tao [4 ]
Schmeltz, Margaux [3 ]
Wimmer, Wilhelm [1 ,6 ]
Schlepuetz, Christian M. [3 ]
Remenschneider, Aaron K. [4 ,5 ]
Bonnin, Anne [3 ]
Anschuetz, Lukas [1 ,7 ,8 ,9 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Inselspital, Freiburgstr, CH-3010 Bern, Switzerland
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Hearing Res Lab, Murtenstr 50, CH-3008 Bern, Switzerland
[3] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
[4] Harvard Med Sch, Eaton Peabody Labs, Massachusetts Eye & Ear, Boston, MA 02114 USA
[5] Harvard Med Sch, Boston Childrens Hosp, Dept Otolaryngol Head & Neck Surg, Boston, MA 02115 USA
[6] Klinikum Rechts Der Isar, TUM Sch Med, Dept Otorhinolaryngol, Munich, Germany
[7] CHUV Ctr Hosp Univ Vaudois, Dept Otorhinolaryngol Head & Neck Surg, Lausanne, Switzerland
[8] Univ Lausanne, Lausanne, Switzerland
[9] Sense Innovat & Res Ctr, Lausanne, Switzerland
关键词
Middle ear; Laser Doppler vibrometry; Dynamic synchrotron-based X-ray microtomography; Phase-contrast; HUMAN MIDDLE-EAR; TYMPANIC MEMBRANE; FREQUENCY; VIBRATION; RECONSTRUCTION; TRANSMISSION; MOTION; CAT;
D O I
10.1007/s10162-024-00971-0
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
PurposeThere are challenges in understanding the biomechanics of the human middle ear, and established methods for studying this system show significant limitations. In this study, we evaluate a novel dynamic imaging technique based on synchrotron X-ray microtomography designed to assess the biomechanical properties of the human middle ear by comparing it to laser-Doppler vibrometry (LDV).MethodsWe examined three fresh-frozen temporal bones (TB), two donated by white males and one by a Black female, using dynamic synchrotron-based X-ray microtomography for 256 and 512 Hz, stimulated at 110 dB and 120 dB sound pressure level (SPL). In addition, we performed measurements on these TBs using 1D LDV, a well-established method.ResultsThe normalized displacement values (mu m/Pa) at the umbo and the posterior crus of the stapes are consistent or within 5-10 dB differences between all LDV and dynamic microtomography measurements and previously reported literature references. In general, the overall behavior is similar between the two measurement techniques.ConclusionIn conclusion, our results demonstrate the suitability of dynamic synchrotron-based X-ray microtomography in studying the middle ear's biomechanics. However, this study shows that better standardization regarding acoustic stimulation and measurement points is needed to better compare the two measurement techniques.
引用
收藏
页码:63 / 75
页数:13
相关论文
共 50 条
  • [1] Dynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative StudyDynamic X-ray Microtomography vs. Laser-Doppler Vibrometry: A Comparative StudyA. Ivanovic et al.
    Aleksandra Ivanovic
    Jeffrey Tao Cheng
    Margaux Schmeltz
    Wilhelm Wimmer
    Christian M. Schlepuetz
    Aaron K. Remenschneider
    Anne Bonnin
    Lukas Anschuetz
    Journal of the Association for Research in Otolaryngology, 2025, 26 (1) : 63 - 75
  • [2] CCD vs. laser: A comparative study of two types of x-ray film digitizers
    Gitlin, JN
    Drinkard, M
    MEDICAL IMAGING 1999 - PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES, 1999, 3662 : 438 - 443
  • [3] Comparison between X-ray Stereoscopy and Laser Doppler Vibrometry for Motion Measurement in Biomechanics
    Salih, Wasil H. M.
    Buytaert, Jan A. N.
    Dirckx, Joris J. J.
    OPTICAL MEASUREMENT TECHNIQUES FOR STRUCTURES & SYSTEMS2 (OPTIMESS2012), 2013, : 359 - 368
  • [4] Study of laser welding of brachytherapy capsules by x-ray microtomography
    Sima, C.
    Grigoriu, C.
    Nicolae, I.
    Tiseanu, I.
    Craciunescu, T.
    Viespe, C.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2015, 9 (7-8): : 1006 - 1009
  • [5] The use of X-ray microtomography in the study of laser effects on enamel and dentine
    Mercer, CE
    Anderson, P
    Davis, GR
    5TH CONGRESS OF THE INTERNATIONAL SOCIETY FOR LASERS IN DENTISTRY, 1996, : 97 - 101
  • [6] A study of Er:YAG laser ablation using X-ray microtomography
    C Longbottom
    British Dental Journal, 2003, 194 (2) : 89 - 89
  • [7] X-ray microtomography analysis of dynamic damage in tantalum
    Bontaz-Carion, Joelle
    Pellegrini, Yves-Patrick
    ADVANCED ENGINEERING MATERIALS, 2006, 8 (06) : 480 - 486
  • [8] Investigating the Microstructure of Frozen Foods Using X-ray Microtomography: A Comparative Study
    Ndoye, Fatou-Toutie
    Bouabdallah, Aouatef
    Benkhelifa, Hayat
    7TH IIR 2022 INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN 2022, 2022, : 345 - 352
  • [9] X-ray microtomography to study the microstructure of mayonnaise
    Laverse, J.
    Mastromatteo, M.
    Frisullo, P.
    Del Nobile, M. A.
    JOURNAL OF FOOD ENGINEERING, 2012, 108 (01) : 225 - 231
  • [10] A comparative study of Langmuir surfactant films: Grazing incidence x-ray off-specular scattering vs. x-ray specular reflectivity
    Dai, Yeling
    Lin, Binhua
    Meron, Mati
    Kim, Kyungil
    Leahy, Brian
    Shpyrko, Oleg G.
    JOURNAL OF APPLIED PHYSICS, 2011, 110 (10)