Incidence and outcomes of cardiovascular implantable electronic device infections in patients with end-stage kidney disease

被引:0
作者
Jiwani, Sania [1 ]
Chan, Wan-Chi [1 ]
Gadre, Akshaya [1 ]
Sheldon, Seth [1 ]
Hu, Jinxiang [2 ]
Pimentel, Rhea [1 ]
Noheria, Amit [1 ]
Gupta, Kamal [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Cardiovasc Med, Kansas City, KS 66160 USA
[2] Univ Kansas, Med Ctr, Dept Biostat & Data Sci, Kansas City, KS 66160 USA
关键词
End-stage kidney disease; Cardiac implantable electronic device infection; Pacemaker; Defibrillator; Lead extraction; Mortality; Reimplantation; RISK-FACTORS;
D O I
10.1016/j.hrthm.2024.09.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND End-stage kidney disease (ESKD) patients are prone to bloodstream infections that may result in a higher risk of cardiac implantable electronic device (CIED) infections. OBJECTIVE The objective of this study was to assess the incidence, risk predictors, management strategies, and long-term outcomes of CIED infections in ESKD patients undergoing de novo CIED implantation. METHODS This is a retrospective study using the United States Renal Data System. ESKD patients with de novo CIED implantation between January 1, 2006, and September 30, 2014, were included. Patients were observed until death, kidney transplantation, end of Medicare coverage, or September 30, 2015, to assess incidence of CIED infection. Management approach was determined from procedure codes for lead extraction within 60 days of CIED infection diagnosis. Patients with CIED infection were observed until December 31, 2019, to assess long-term outcomes. RESULTS Of 15,515 ESKD patients undergoing de novo CIED implantation, incidence of CIED infection was 4.8% during a median follow-up of 1.3 years. The presence of a defibrillator (adjusted hazard ratio [aHR], 1.48), higher body mass index (aHR, 1.01), and younger age (aHR, 0.96) were independent risk factors for CIED infection. Lead extraction occurred in only 50.71% of patients by 60 days. After propensity score matching, the 3-year mortality was higher in those who did not undergo lead extraction compared with those who did (80.3% vs 72.3%) and time to mortality was shorter (0.3 vs 0.6 year). Only 13.8% of patients underwent reimplantation with a new CIED after lead extraction. CONCLUSION CIED infections occur frequently in ESKD patients and are associated with a high mortality. Early lead extraction is not performed routinely but is associated with improved survival.
引用
收藏
页码:744 / 751
页数:8
相关论文
共 15 条
[1]   Transvenous Lead Extraction in Chronic Kidney Disease and Dialysis Patients With Infected Cardiac Devices [J].
Barakat, Amr F. ;
Wazni, Oussama M. ;
Tarakji, Khaldoun G. ;
Callahan, Thomas ;
Nimri, Nayef ;
Saliba, Walid I. ;
Shah, Shailee ;
Rehman, Karim Abdur ;
Rickard, John ;
Brunner, Michael P. ;
Martin, David O. ;
Kanj, Mohamed ;
Baranowski, Bryan ;
Cantillon, Daniel ;
Niebauer, Mark ;
Dresing, Thomas ;
Lindsay, Bruce D. ;
Wilkoff, Bruce L. ;
Hussein, Ayman A. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (01)
[2]   Risk Factors for Infections Involving Cardiac Implanted Electronic Devices [J].
Birnie, David H. ;
Wang, Jia ;
Alings, Marco ;
Philippon, Francois ;
Parkash, Ratika ;
Manlucu, Jaimie ;
Angaran, Paul ;
Rinne, Claus ;
Coutu, Benoit ;
Low, R. Aaron ;
Essebag, Vidal ;
Morillo, Carlos ;
Redfearn, Damian ;
Toal, Satish ;
Becker, Giuliano ;
Degrace, Michel ;
Thibault, Bernard ;
Crystal, Eugene ;
Tung, Stanley ;
LeMaitre, John ;
Sultan, Omar ;
Bennett, Matthew ;
Bashir, Jamil ;
Ayala-Paredes, Felix ;
Gervais, Philippe ;
Rioux, Leon ;
Hemels, Martin E. W. ;
Bouwels, Leon H. R. ;
Exner, Derek V. ;
Dorian, Paul ;
Connolly, Stuart J. ;
Longtin, Yves ;
Krahn, Andrew D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (23) :2845-2854
[3]   Device-related infection in de novo transvenous implantable cardioverter-defibrillator Medicare patients [J].
El-Chami, Mikhael F. ;
Jacobsen, Caroline M. ;
Griffiths, Robert, I ;
Hansen, Linda K. ;
Wold, Nick ;
Amorosi, Stacey L. ;
Stivland, Timothy M. ;
Knight, Bradley P. ;
Weiss, Raul ;
Mark, George E. ;
Biffi, Mauro ;
Probst, Vincent ;
Lambiase, Pier D. ;
Miller, Marc A. ;
Baddour, Larry M. .
HEART RHYTHM, 2021, 18 (08) :1301-1309
[4]   Cardiac implantable electronic device infection in patients with end-stage renal disease [J].
Guha, Avirup ;
Maddox, William R. ;
Colombo, Rhonda ;
Nahman, N. Stanley, Jr. ;
Kintziger, Kristina W. ;
Waller, Jennifer L. ;
Diamond, Matthew ;
Murphy, Michele ;
Kheda, Mufaddal ;
Litwin, Sheldon E. ;
Sorrentino, Robert A. .
HEART RHYTHM, 2015, 12 (12) :2395-2401
[5]   Extraction outcomes of implantable cardioverter-defibrillator leads vary by manufacturer and model family [J].
Hayashi, Katsuhide ;
Callahan, Thomas ;
Rickard, John ;
Younis, Arwa ;
Baranowski, Bryan ;
Martin, David ;
Nakhla, Shady ;
Tabaja, Chadi ;
Wilkoff, Bruce L. .
EUROPACE, 2023, 25 (12)
[6]   Clinical Presentation and Outcomes of Cardiovascular Implantable Electronic Device Infections in Hemodialysis Patients [J].
Hickson, LaTonya J. ;
Gooden, Janelle Y. ;
Le, Katherine Y. ;
Baddour, Larry M. ;
Friedman, Paul A. ;
Hayes, David L. ;
Wilson, Walter R. ;
Steckelberg, James M. ;
Sohail, M. Rizwan .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2014, 64 (01) :104-110
[7]   Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982-2018) [J].
Olsen, Thomas ;
Jorgensen, Ole Dan ;
Nielsen, Jens Cosedis ;
Thogersen, Anna Margrethe ;
Philbert, Berit Thornvig ;
Johansen, Jens Brock .
EUROPEAN HEART JOURNAL, 2019, 40 (23) :1862-1869
[8]   Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis [J].
Polyzos, Konstantinos A. ;
Konstantelias, Athanasios A. ;
Falagas, Matthew E. .
EUROPACE, 2015, 17 (05) :767-777
[9]   Rates of and Factors Associated With Infection in 200 909 Medicare Implantable Cardioverter-Defibrillator Implants Results From the National Cardiovascular Data Registry [J].
Prutkin, Jordan M. ;
Reynolds, Matthew R. ;
Bao, Haikun ;
Curtis, Jeptha P. ;
Al-Khatib, Sana M. ;
Aggarwal, Saurabh ;
Uslan, Daniel Z. .
CIRCULATION, 2014, 130 (13) :1037-1043
[10]   Device infections in implantable cardioverter defibrillators versus permanent pacemakers: A systematic review and meta-analysis [J].
Rattanawong, Pattara ;
Kewcharoen, Jakrin ;
Mekraksakit, Poemlarp ;
Mekritthikrai, Raktham ;
Prasitlumkum, Narut ;
Vutthikraivit, Wasawat ;
Putthapiban, Prapaipan ;
Dworkin, Jonathan .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (07) :1053-1065