Biomechanical Evaluation of Cervical Interbody Fusion Cages for Anterior Cervical Discectomy and Fusion With Variations in Morphology: A Finite Element Analysis

被引:0
|
作者
Manickam, Pechimuthu Susai [1 ]
Dhason, Raja [2 ]
Bock, Ryan [3 ]
Bal, Sonny [3 ]
Roy, Sandipan [1 ]
Datta, Shubhabrata [2 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Ctr Biomech, Dept Mech Engn, Kattankulathur, Tamil Nadu, India
[2] SRM Inst Sci & Technol, Coll Engn & Technol, Ctr Composites & Adv Mat, Dept Mech Engn, kattankulathur, Tamil Nadu, India
[3] SINTX Technol, Salt Lake City, UT USA
来源
BIOMEDICAL ENGINEERING AND COMPUTATIONAL BIOLOGY | 2025年 / 16卷
关键词
Cage; finite element analysis; cervical spine; ACDF; disc degeneration; SILICON-NITRIDE; SPONDYLOTIC MYELOPATHY; MECHANICAL-PROPERTIES; SUBSIDENCE; ADJACENT; DECOMPRESSION; INTERFACE; CERAMICS; FIXATION; DENSITY;
D O I
10.1177/11795972251321307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The spinal diseases commonly faced by people in the 19th century included intervertebral disc degeneration, tuberculosis and congenital defects that resulted in neurological impairment and global disability. To address these issues, cervical spine surgery was performed. Modern techniques currently used in spine surgery include interbody devices, pedicle screws, artificial discs and bone grafts. The postoperative complications clinically reported during follow-up include nonunion and implant subsidence, which remain significant drawbacks. The objective of this study is to develop a 3-dimensional finite element model of the C2-C7 cervical spine and validate it against existing experimental studies. The loading conditions considered for this study include a compressive preload of 50 N and a 1 Nm moment applied to the C2 vertebra, with the C7 vertebra fixed at the bottom. In this study, the biomechanical alterations of 4 different cage morphologies were analysed using finite element analysis. Valeo cages with 4 distinct designs were implanted at the C5-C6 level, and physiological motion at the surgical site was studied. Cage subsidence and migration, which can lead to adjacent segment disc degeneration, were also examined. Subsidence was primarily attributed to higher stress encountered in the cage, so stress distribution within the cages was evaluated. Additionally, stress distribution in the anterior plate and screws was analysed. The study concludes that introducing anterior plate and screw fixation helps prevent cage subsidence. Physiological motion at the surgical level was reduced compared to the intact model. Adjacent disc stress was also evaluated and found to be lower than in the intact model.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Biomechanical evaluation of a novel anterior transpedicular screw-plate system for anterior cervical corpectomy and fusion (ACCF): a finite element analysis
    Huang, Shengbin
    Ling, Qinjie
    Lin, Xinxin
    Qin, Hao
    Luo, Xiang
    Huang, Wenhua
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [32] Biomechanical effect of endplate defects on the intermediate vertebral bone in consecutive two-level anterior cervical discectomy and fusion: a finite element analysis
    Jiarui Zhang
    Wenzhao Chen
    Rui Weng
    De Liang
    Xiaobing Jiang
    Hongheng Lin
    BMC Musculoskeletal Disorders, 24
  • [33] Outcomes of Interbody Fusion Cages Used in 1 and 2-levels Anterior Cervical Discectomy and Fusion Titanium Cages Versus Polyetheretherketone (PEEK) Cages
    Niu, Chi-Chien
    Liao, Jen-Chung
    Chen, Wen-Jer
    Chen, Lih-Huei
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (05): : 310 - 316
  • [34] Performing an Anterior Cervical Discectomy and Fusion
    Schroeder, Gregory D.
    Kurd, Mark F.
    Millhouse, Paul W.
    Vaccaro, Alexander R.
    Hilibrand, Alan S.
    CLINICAL SPINE SURGERY, 2016, 29 (05): : 186 - 190
  • [35] A Meta-Analysis of Surgical Outcomes in 25727 Patients Undergoing Anterior Cervical Discectomy and Fusion or Anterior Cervical Corpectomy and Fusion for Cervical Deformity
    Barot, Karma
    Ruiz-Cardozo, Miguel A.
    Singh, Som
    Trevino, Gabriel
    Kann, Michael R.
    Brehm, Samuel
    Bui, Tim
    Joseph, Karan
    Patel, Rujvee
    Hardi, Angela
    Yahanda, Alexander T.
    Jauregui, Julio J.
    Cadieux, Magalie
    Pennicooke, Brenton
    Molina, Camilo A.
    GLOBAL SPINE JOURNAL, 2025, 15 (02) : 1390 - 1404
  • [36] Biomechanical comparison of instrumented posterior lumbar interbody fusion with one or two cages by finite element analysis
    Chiang, Ming-Fu
    Zhong, Zheng-Cheng
    Chen, Chen-Sheng
    Cheng, Cheng-Kung
    Shih, Shih-Liang
    SPINE, 2006, 31 (19) : E682 - E689
  • [37] Biomechanical evaluation of single- and multi-level anterior cervical discectomy and fusion with polyetheretherketone cages: radiological and clinical outcomes
    Zapolska, Gabriela
    Kwiatkowski, Michal
    Turek, Grzegorz
    Mariak, Zenon
    Hermanowicz, Adam
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2019, 53 (05) : 358 - 362
  • [38] Biomechanical evaluation of the novel assembled internal fixed system in C2-C3 anterior cervical discectomy and fusion: a finite element analysis
    Chen, Hu
    Sun, Hao
    Cao, Lu
    Xia, Hong
    Tu, Qiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [39] Biomechanical Comparison of Posterior Lumbar Interbody Fusion and Transforaminal Lumbar Interbody Fusion by Finite Element Analysis
    Xu, Hao
    Tang, Hao
    Guan, Xuemei
    Jiang, Fugui
    Xu, Neng
    Ju, Wen
    Zhu, Xiaodong
    Zhang, Xiaojian
    Zhang, Qiulin
    Li, Ming
    NEUROSURGERY, 2013, 72 : 21 - 26
  • [40] Dynamic Fusion Process in the Anterior Cervical Discectomy and Fusion with Self-Locking Stand-Alone Cages
    Xiong, Yang
    Xu, Lin
    Bi, Lian-Yong
    Yang, Ji-Zhou
    Wang, Feng-Xian
    Qu, Yi
    Zhao, Zi-Yi
    Yang, Yong-Dong
    Zhao, Ding-Yan
    Li, Chuan-Hong
    Yu, Xing
    WORLD NEUROSURGERY, 2019, 125 : E678 - E687