Biomechanical Evaluation of Cervical Interbody Fusion Cages for Anterior Cervical Discectomy and Fusion With Variations in Morphology: A Finite Element Analysis

被引:0
|
作者
Manickam, Pechimuthu Susai [1 ]
Dhason, Raja [2 ]
Bock, Ryan [3 ]
Bal, Sonny [3 ]
Roy, Sandipan [1 ]
Datta, Shubhabrata [2 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Ctr Biomech, Dept Mech Engn, Kattankulathur, Tamil Nadu, India
[2] SRM Inst Sci & Technol, Coll Engn & Technol, Ctr Composites & Adv Mat, Dept Mech Engn, kattankulathur, Tamil Nadu, India
[3] SINTX Technol, Salt Lake City, UT USA
来源
BIOMEDICAL ENGINEERING AND COMPUTATIONAL BIOLOGY | 2025年 / 16卷
关键词
Cage; finite element analysis; cervical spine; ACDF; disc degeneration; SILICON-NITRIDE; SPONDYLOTIC MYELOPATHY; MECHANICAL-PROPERTIES; SUBSIDENCE; ADJACENT; DECOMPRESSION; INTERFACE; CERAMICS; FIXATION; DENSITY;
D O I
10.1177/11795972251321307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The spinal diseases commonly faced by people in the 19th century included intervertebral disc degeneration, tuberculosis and congenital defects that resulted in neurological impairment and global disability. To address these issues, cervical spine surgery was performed. Modern techniques currently used in spine surgery include interbody devices, pedicle screws, artificial discs and bone grafts. The postoperative complications clinically reported during follow-up include nonunion and implant subsidence, which remain significant drawbacks. The objective of this study is to develop a 3-dimensional finite element model of the C2-C7 cervical spine and validate it against existing experimental studies. The loading conditions considered for this study include a compressive preload of 50 N and a 1 Nm moment applied to the C2 vertebra, with the C7 vertebra fixed at the bottom. In this study, the biomechanical alterations of 4 different cage morphologies were analysed using finite element analysis. Valeo cages with 4 distinct designs were implanted at the C5-C6 level, and physiological motion at the surgical site was studied. Cage subsidence and migration, which can lead to adjacent segment disc degeneration, were also examined. Subsidence was primarily attributed to higher stress encountered in the cage, so stress distribution within the cages was evaluated. Additionally, stress distribution in the anterior plate and screws was analysed. The study concludes that introducing anterior plate and screw fixation helps prevent cage subsidence. Physiological motion at the surgical level was reduced compared to the intact model. Adjacent disc stress was also evaluated and found to be lower than in the intact model.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Biomechanical analysis of customized cage conforming to the endplate morphology in anterior cervical discectomy fusion: A finite element analysis
    Sun, Bin
    Han, Qing
    Sui, FengXu
    Zhang, AoBo
    Liu, Yang
    Xia, Peng
    Wang, JinCheng
    Yang, XiaoYu
    HELIYON, 2023, 9 (01)
  • [2] Biomechanical evaluation of a novel individualized zero-profile cage for anterior cervical discectomy and fusion: a finite element analysis
    Wang, Yang
    Liu, Yang
    Zhang, Aobo
    Han, Qing
    Jiao, Jianhang
    Chen, Hao
    Gong, Xuqiang
    Luo, Wangwang
    Yue, Jing
    Zhao, Xue
    Wang, Jincheng
    Wu, Minfei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [3] Biomechanical Evaluation of Intervertebral Fusion Process After Anterior Cervical Discectomy and Fusion: A Finite Element Study
    Shen, Yi-Wei
    Yang, Yi
    Liu, Hao
    Qiu, Yue
    Li, Ming
    Ma, Li-Tai
    Gan, Fang-Ji
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [4] Biomechanical Comparison of Anterior Cervical Corpectomy Decompression and Fusion, Anterior Cervical Discectomy and Fusion, and Anterior Controllable Antedisplacement and Fusion in the Surgical Treatment of Multilevel Cervical Spondylotic Myelopathy: A Finite Element Analysis
    Kong, Qingjie
    Li, Fudong
    Yan, Chen
    Sun, Jingchuan
    Sun, Peidong
    Ou-Yang, Jun
    Zhong, Shizhen
    Wang, Yuan
    Shi, Jiangang
    ORTHOPAEDIC SURGERY, 2024, 16 (03) : 687 - 699
  • [5] Finite element analysis of anterior cervical spine interbody fusion
    Kumaresan, S
    Yoganandan, N
    Pintar, FA
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1997, 7 (04) : 221 - 230
  • [6] The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review
    Elizabeth Chong
    Matthew H Pelletier
    Ralph J Mobbs
    William R Walsh
    BMC Musculoskeletal Disorders, 16
  • [7] The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review
    Chong, Elizabeth
    Pelletier, Matthew H.
    Mobbs, Ralph J.
    Walsh, William R.
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [8] Anterior cervical discectomy without interbody fusion
    Donaldson, JW
    Nelson, PB
    Hernesniemi, J
    Pawl, RP
    Portnoy, HD
    Wirth, FP
    SURGICAL NEUROLOGY, 2002, 57 (04): : 219 - 225
  • [9] Biomechanical effect of endplate defects on the intermediate vertebral bone in consecutive two-level anterior cervical discectomy and fusion: a finite element analysis
    Zhang, Jiarui
    Chen, Wenzhao
    Weng, Rui
    Liang, De
    Jiang, Xiaobing
    Lin, Hongheng
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [10] Biomechanical Analysis of Biodegradable Cervical Plates Developed for Anterior Cervical Discectomy and Fusion
    Cho, Pyung Goo
    Ji, Gyu Yeul
    Park, Sang Hyuk
    Shin, Dong Ah
    ASIAN SPINE JOURNAL, 2018, 12 (06) : 1092 - 1099