Detection of mpox and other orthopoxviruses using a lateral flow device as a point-of-care diagnostic

被引:0
|
作者
Laidlaw, Stephen M. [1 ,2 ]
Ulaeto, David [3 ]
Lonsdale, Steve [3 ]
Clark, Graeme [3 ]
Sumner, Rebecca [4 ]
Edwards, Thomas [5 ]
Adams, Emily [5 ,6 ]
Logist, Anne-Sophie [7 ]
Van Holm, Bram [7 ]
de Motes, Carlos Maluquer [4 ]
Horby, Peter [1 ]
Maes, Piet [7 ]
Carroll, Miles W. [1 ,2 ]
机构
[1] Univ Oxford, Pandem Sci Inst PSI, Oxford, England
[2] Univ Oxford, Ctr Human Genet CHG, Oxford, England
[3] DSTL, Salisbury, England
[4] Univ Surrey, Dept Microbial Sci, Guildford, England
[5] Univ Liverpool Liverpool Sch Trop Med, Dept Trop Dis Biol, Liverpool, England
[6] Global Access Diagnost, Bedford, England
[7] Katholieke Univ Leuven, Rega Inst, Lab Clin & Epidemiol Virol, Leuven, Belgium
基金
英国生物技术与生命科学研究理事会;
关键词
mpox; LFD; diagnostics; VACCINIA VIRUS; ASSAY; PROTEINS; IMMUNOGENICITY; IDENTIFICATION; MONKEYPOX; ELISA; HOST;
D O I
10.1128/spectrum.02456-24
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In 2022, the World Health Organization declared the worldwide outbreak of mpox to be a public health emergency of international concern. The causative monkeypox virus (MPXV) belonged to clade IIb and is transmitted through sexual contact with a low case fatality rate (0.1%), which, together with under-detection, all contributed to a rapid global spread particularly within the MSM (men who have sex with men) community. As MPXV clade II remains circulating worldwide, a new outbreak of the more fatal clade I disease has been declared in Central and East Africa, and remains uncontrolled in part due to the lack of point-of-care (POC) diagnostics for rapid decisions on treatment and self-isolation. To address the lack of POC solutions for mpox, we have designed and evaluated an orthopoxvirus-specific lateral flow device (LFD) that could be used for the diagnosis of mpox. Using an LFD comprising four monoclonal antibodies against the A27 protein, we demonstrate sensitivity to 3 x 10(5) pfu/mL. This sensitivity is expected to be sufficient for the detection of MPXV from lesion sites and may also be sufficient for other sample types such as saliva and urine. We found that the presence of guanidinium thiocyanate, a common ingredient in inactivating viral transport media, masked the LFD antigen, resulting in false negatives. POC diagnosis of mpox may be possible using an LFD to reduce delays arising from sample shipment to centralized laboratory testing facilities. In order to achieve this, our work demonstrates that an LFD-optimized buffer is required, as the sample collection buffer may have a detrimental impact on sensitivity for clinical material. IMPORTANCE Mpox cases have dramatically increased both in traditionally monkeypox virus endemic countries and also worldwide. This increase comes at a time when immunity derived from smallpox vaccination is no longer available. Diagnosis of mpox is complicated due to both disease presentation and the availability of local diagnostic laboratories. The availability of a point-of-care diagnostic tool such as an lateral flow device (LFD) would play an important role to both diagnose and prevent onward transmission. This manuscript provides developers and assessors with key data for defining true sensitivity and specificity of a successful LFD in addition to buffer conditions for sample collection.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Developments in Point-of-Care Diagnostic Technology for Cancer Detection
    Hayes, Bryony
    Murphy, Caroline
    Crawley, Aoife
    O'Kennedy, Richard
    DIAGNOSTICS, 2018, 8 (02):
  • [12] A simple cassette as point-of-care diagnostic device for naked-eye colorimetric bacteria detection
    Safavieh, Mohammadali
    Ahmed, Minhaz Uddin
    Sokullu, Esen
    Ng, Andy
    Braescuac, Liliana
    Zourob, Mohammed
    ANALYST, 2014, 139 (02) : 482 - 487
  • [13] Isothermal Recombinase Polymerase Amplification-Lateral Flow Point-of-Care Diagnostic Test for Heartland Virus
    Shelite, Thomas R.
    Bopp, Nathen E.
    Moncayo, Abelardo
    Reynolds, Erin S.
    Thangamani, Saravanan
    Melby, Peter C.
    Bloch, Karen
    Aguilar, Patricia, V
    Travi, Bruno L.
    VECTOR-BORNE AND ZOONOTIC DISEASES, 2021, 21 (02) : 110 - 115
  • [14] Point-of-care detection of glycated hemoglobin using a novel dry chemistry-based electrochemiluminescence device
    Zhou, Xinya
    Lai, Wei
    Zhong, Jinbiao
    Yang, Yang
    Chen, Zhenyu
    Zhang, Chunsun
    ANALYTICA CHIMICA ACTA, 2023, 1279
  • [15] An enhanced centrifugation-assisted lateral flow immunoassay for the point-of-care detection of protein biomarkers
    Shen, Minjie
    Li, Nan
    Lu, Ying
    Cheng, Jing
    Xu, Youchun
    LAB ON A CHIP, 2020, 20 (15) : 2626 - 2634
  • [16] Diagnostic performance of oral swab specimen for SARS-CoV-2 detection with rapid point-of-care lateral flow antigen test
    Mane, Arati
    Jain, Shilpa
    Jain, Ankita
    Pereira, Michael
    Sirsat, Atul
    Pathak, Gaurav
    Bhoi, Vikalp
    Bhavsar, Shailaja
    Panda, Samiran
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [17] Palm-Sized Device for Point-of-Care Ebola Detection
    Ahrberg, Christian D.
    Manz, Andreas
    Neuzil, Pavel
    ANALYTICAL CHEMISTRY, 2016, 88 (09) : 4803 - 4807
  • [18] Detection of Cannabinoids in Oral Fluid Specimens as the Preferred Biological Matrix for a Point-of-Care Biosensor Diagnostic Device
    Trif, Calin
    Harpaz, Dorin
    Eltzov, Evgeni
    Parcharoen, Yardnapar
    Pechyen, Chiravoot
    Marks, Robert S.
    BIOSENSORS-BASEL, 2024, 14 (03):
  • [19] Development of Lateral Flow Assay for Point-of-Care Diagnosis of Trypanosomosis in Equines
    Kumar, Ritesh
    Dilbaghi, Neeraj
    Kumar, Sandeep
    Gupta, Ashok K.
    Khurana, Sandip K.
    Yadav, Suresh C.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2018, 70 : 1 - 6
  • [20] Lateral Flow Immunoassay Reader Technologies for Quantitative Point-of-Care Testing
    Park, Jongwon
    SENSORS, 2022, 22 (19)