Tunable and real-time automatic interventional x-ray collimation from semi-supervised deep feature extraction

被引:0
|
作者
Lee, Brian C. [1 ]
Rijhwani, Damini [1 ]
Lang, Sydney [1 ]
van Oorde-Grainger, Shaun [2 ]
Haak, Alexander [1 ]
Bleise, Carlos [3 ]
Lylyk, Pedro [3 ]
Ruijters, Daniel [2 ]
Sinha, Ayushi [1 ]
机构
[1] Philips Res, 222 Jacobs St, Cambridge, MA 02141 USA
[2] Philips Healthcare, Best, Netherlands
[3] ENERI, Dept Radiol, Buenos Aires, Argentina
关键词
collimation; endovascular surgery; interventional radiology; x-ray; VISUAL-ATTENTION; IMAGES; MODEL;
D O I
10.1002/mp.17522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe use of endovascular procedures is becoming increasingly popular across multiple clinical domains. These procedures are generally performed under image guidance using an interventional c-arm x-ray system. Radiation exposure to both patients and interventional staff due to use of fluoroscopy is a health and occupational concern, but modifications to the interventional workflow to address radiation may come at the cost of procedure time or quality.PurposeInterventional x-ray collimation is a crucial task for improving image quality as well as reducing radiation exposure to both patients and operators who work in the x-ray domain. However, collimation is heavily underutilized due to its cumbersome nature and the difficulty of manually manipulating multiple parameters during fast-paced interventional procedures. Additionally, the widely varying collimation preferences of interventionalists across different procedure types, procedure phases, and anatomies makes the standardizing of collimation challenging for radiation technologist support staff.MethodsAutomating collimation has the potential to bridge this gap, freeing up mental bandwidth for interventionalists and technologists and improving outcomes for patients. Here, we propose a tunable algorithm for automatic collimation based on a region-of-interest optimizer driven by a combination of image, system, device, and radiation based features and we illustrate its efficacy across varying personal preferences. Critically, we devise a method with a simple and easily understandable mapping between algorithm parameters and practical outcomes.ResultsWe show a real-time implementation of this algorithm using deep feature extraction by a convolutional neural network and evaluate its performance in a custom dataset of simulated fluoroscopy and recorded fluoroscopy from clinical radial access procedures. We evaluate the effects of a practically implemented mixed supervision training strategy on model performance and show potential for radiation reduction in simulation. An uncertainty analysis indicates that the algorithm is robust to noise and anatomical variation across our clinical dataset. Clinical acceptability and quality is evaluated through a reader study with expert neuro-interventional radiologists, with participants indicating 100% clinical acceptability, high quality ratings, and improved radiation protection over their typical practice.ConclusionsThe algorithm's modular design ensured that users' collimation requirements were met without disruption to the interventional workflow or procedure time, while exhibiting strong potential to reduce radiation risk to patients and operators. Evaluation in more varied clinical settings could support translation of this technology into the clinic.
引用
收藏
页码:1372 / 1389
页数:18
相关论文
共 45 条
  • [21] Real-time liver tumor localization via combined surface imaging and a single x-ray projection
    Shao, Hua-Chieh
    Li, Yunxiang
    Wang, Jing
    Jiang, Steve
    Zhang, You
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (06)
  • [22] In-situ real-time x-ray quality assessment of BGA and uBGA connections during soldering
    Scholz, O
    Eisenbarth, M
    Hanke, R
    Bigl, T
    Schmitt, P
    TESTING, RELIABILITY, AND APPLICATION OF MICRO- AND NANO-MATERIAL SYSTEMS, 2003, 5045 : 147 - 156
  • [23] Real-time detection of gastrointestinal leaks via bismuth chelate-enhanced X-ray gastroenterography
    Pan, Jinbin
    Wang, Jiaojiao
    Zhao, Yujie
    Han, Bing
    Shu, Gang
    Ma, Min
    Wang, Xu
    Wei, Xi
    Hou, Wenjing
    Sun, Shao-Kai
    BIOMATERIALS, 2024, 311
  • [24] Real-time liver tumor localization via a single x-ray projection using deep graph neural network-assisted biomechanical modeling
    Shao, Hua-Chieh
    Wang, Jing
    Bai, Ti
    Chun, Jaehee
    Park, Justin C.
    Jiang, Steve
    Zhang, You
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (11)
  • [25] On-Line and Real-Time Analysis of Moisture Content in Activated Carbon Powder by X-Ray Scattering Technique
    Choi, Yong Suk
    Hwang, Jaesik
    Kim, Jong-Yun
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (13) : 4067 - 4069
  • [26] 3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy
    Li, Ruijiang
    Lewis, John H.
    Jia, Xun
    Gu, Xuejun
    Folkerts, Michael
    Men, Chunhua
    Song, William Y.
    Jiang, Steve B.
    MEDICAL PHYSICS, 2011, 38 (05) : 2783 - 2794
  • [27] Real-time X-ray radiography for defect detection in submerged arc welding and segmentation using sparse signal representation
    Gao, Weixin
    Hu, Yu Hen
    INSIGHT, 2014, 56 (06) : 299 - 307
  • [28] Ensemble Technique Coupled with Deep Transfer Learning Framework for Automatic Detection of Tuberculosis from Chest X-ray Radiographs
    Kotei, Evans
    Thirunavukarasu, Ramkumar
    HEALTHCARE, 2022, 10 (11)
  • [29] Real-time tumor localization with single x-ray projection at arbitrary gantry angles using a convolutional neural network (CNN)
    Wei, Ran
    Zhou, Fugen
    Liu, Bo
    Bai, Xiangzhi
    Fu, Dongshan
    Liang, Bin
    Wu, Qiuwen
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (06)
  • [30] Real-time monitoring of laser powder bed fusion process using high-speed X-ray imaging and diffraction
    Zhao, Cang
    Fezzaa, Kamel
    Cunningham, Ross W.
    Wen, Haidan
    De Carlo, Francesco
    Chen, Lianyi
    Rollett, Anthony D.
    Sun, Tao
    SCIENTIFIC REPORTS, 2017, 7