Optimizing range of motion in reverse shoulder arthroplasty

被引:2
作者
Mouchantaf, M. [1 ]
Parisi, M. [1 ]
Secci, G. [1 ]
Biegun, M. [1 ]
Chelli, M. [1 ]
Schippers, P. [1 ]
Boileau, P. [1 ]
机构
[1] Inst Chirurg Reparatrice ICR Locomoteur & Sports, Nice, France
来源
BONE & JOINT OPEN | 2024年 / 5卷 / 10期
关键词
GLENOID LATERALIZATION; INCLINATION; ANGLE; BONE; TILT;
D O I
10.1302/2633-1462.510.BJO-2024-0097.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM. Methods With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135 degrees inclined polyethylene liner. Results The configuration with lateralization and correction of the RSA angle (C+L+) led to better ROM in flexion, extension, adduction, and external rotation (p <= 0.001). Only internal rotation was not significantly different between groups (p = 0.388). The configuration where correction of the inclination was done by medialization (C+M+) led to the worst ROM in adduction, extension, abduction, flexion, and external rotation of the shoulder. Conclusion Our software study shows that, when using a 135 degrees inlay reversed humeral implant, correcting glenoid inclination (RSA angle 0 degrees) and lateralizing the glenoid component by using an angled bony or metallic augment of 8 to 10 mm provides optimal impingement-free ROM.
引用
收藏
页码:851 / 857
页数:7
相关论文
共 50 条
[41]   Avoiding superior tilt in reverse shoulder arthroplasty: a review of the literature and technical recommendations [J].
Laver, Lior ;
Garrigues, Grant E. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (10) :1582-1590
[42]   Reverse total shoulder arthroplasty for oncologic reconstruction of the proximal humerus: a systematic review [J].
Ferlauto, Harrison R. ;
Wickman, John R. ;
Lazarides, Alexander L. ;
Hendren, Stephanie ;
Visgauss, Julia D. ;
Brigman, Brian E. ;
Anakwenze, Oke A. ;
Klifto, Christopher S. ;
Eward, William C. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (11) :E647-E658
[43]   Implications of navigation system use for glenoid component placement in reverse shoulder arthroplasty [J].
Kida, Hiroaki ;
Urita, Atsushi ;
Momma, Daisuke ;
Matsui, Yuki ;
Endo, Takeshi ;
Kawamura, Daisuke ;
Taneichi, Hiroshi ;
Iwasaki, Norimasa .
SCIENTIFIC REPORTS, 2022, 12 (01)
[44]   Minimum two-year follow-up of a reverse total shoulder arthroplasty using a wedged baseplate [J].
Parker, Simon J. M. ;
Bell, Simon N. ;
Wiemer, Feoline ;
Coghlan, Jennifer A. ;
Clitherow, Harry D. ;
Rayment, Helen M. .
SHOULDER & ELBOW, 2024,
[45]   The Glenoid Component in Anatomic Shoulder Arthroplasty [J].
Pinkas, Daphne ;
Wiater, Brett ;
Wiater, J. Michael .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2015, 23 (05) :317-326
[46]   The effect of lateralization and distalization after Grammont-style reverse total shoulder arthroplasty [J].
Clinker, Chris ;
Ishikawa, Hiroaki ;
Presson, Angela P. ;
Zhang, Chong ;
Joyce, Christopher ;
Chalmers, Peter N. ;
Tashjian, Robert Z. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (12) :2664-2670
[47]   Postoperative radiographic findings of an uncemented convertible short stem for anatomic and reverse shoulder arthroplasty [J].
Raiss, Patric ;
Schnetzke, Marc ;
Wittmann, Thomas ;
Kilian, Christopher M. ;
Edwards, T. Bradley ;
Denard, Patrick J. ;
Neyton, Lionel ;
Godeneche, Arnaud ;
Watch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (04) :715-723
[48]   Reverse shoulder arthroplasty glenoid fixation: is there a benefit in using four instead of two screws? [J].
James, Jaison ;
Allison, Mari A. ;
Werner, Frederick W. ;
McBride, Devin E. ;
Basu, Niladri N. ;
Sutton, Levi G. ;
Nanavati, Vipul N. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (08) :1030-1036
[49]   Neutral glenoid alignment in reverse shoulder arthroplasty does not guarantee decreased risk of impingement [J].
Berhouet, Julien ;
Gulotta, Lawrence ;
Chen, Xiang ;
Dines, David ;
Warren, Russel ;
Kontaxis, Andreas .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (04) :1213-1219
[50]   Radiological outcome in reverse shoulder arthroplasty does not correlate with patient satisfaction or quality of life [J].
Kijewski, Leonie L. ;
Springer, Bernhard ;
Windhager, Reinhard ;
Koller, Ulrich K. K. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (08) :1857-1866