Pelvic target volume motion for cervical cancer with daily iterative cone beam computed tomography

被引:0
|
作者
Zeng, Zheng [1 ]
Zhang, Fuquan [2 ]
Yan, Junfang [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Dept Radiat Oncol, Peking Union Med Coll Hosp, Beijing, Peoples R China
[2] Chinese Acad Med Sci & Peking Union Med Coll, Dept Radiat Oncol, Peking Union Med Coll Hosp, State Key Lab Complex Severe & Rare Dis, Beijing, Peoples R China
关键词
cervical cancer; inter-fractional motion; INTENSITY-MODULATED RADIOTHERAPY; ORGAN MOTION; RADIATION; IMRT; IGRT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
78
引用
收藏
页码:S139 / S141
页数:3
相关论文
共 50 条
  • [41] The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography
    Hou, Wei-Hsien
    Wang, Chun-Wei
    Tsai, Chiao-Ling
    Hsu, Feng-Ming
    Cheng, Jason Chia-Hsien
    RADIOLOGY AND ONCOLOGY, 2016, 50 (04) : 427 - 432
  • [42] CONE BEAM COMPUTED TOMOGRAPHY-DERIVED ADAPTIVE RADIOTHERAPY FOR RADICAL TREATMENT OF ESOPHAGEAL CANCER
    Hawkins, Maria A.
    Brooks, Corrinne
    Hansen, Vibeke N.
    Aitken, Alexandra
    Tait, Diana M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (02): : 378 - 383
  • [43] A Consensus-based Guideline Defining the Clinical Target Volume for Pelvic Lymph Nodes in External Beam Radiotherapy for Uterine Cervical Cancer
    Toita, Takafumi
    Ohno, Tatsuya
    Kaneyasu, Yuko
    Uno, Takashi
    Yoshimura, Ryouichi
    Kodaira, Takeshi
    Furutani, Kazuhisa
    Kasuya, Goro
    Ishikura, Satoshi
    Kamura, Toshiharu
    Hiraoka, Masahiro
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2010, 40 (05) : 456 - 463
  • [44] Volume computed tomography perfusion as a predictive marker for treatment response to concurrent chemoradiotherapy in cervical cancer: a prospective study
    Dong Rui, Tong
    Dong, Yue
    Song Qing, Ling
    Tong, Rui
    Wang Fei, Fei
    Yu, Tao
    Luo, YaHong
    ACTA RADIOLOGICA, 2021, 62 (02) : 281 - 288
  • [45] Impact of cone-beam computed tomography artifacts on dose calculation accuracy for lung cancer
    Schroder, Lukas
    Bootsma, Gregory
    Stankovic, Uros
    Ploeger, Lennert
    Sonke, Jan-Jakob
    MEDICAL PHYSICS, 2024, 51 (07) : 4709 - 4720
  • [46] Intensity-modulated radiotherapy is superior to three-dimensional conformal radiotherapy in the trimodality management of muscle-invasive bladder cancer with daily cone beam computed tomography optimization
    Sherry, Alexander D.
    Stewart, Adam
    Luo, Guozhen
    Kirschner, Austin N.
    JOURNAL OF RADIATION ONCOLOGY, 2019, 8 (04) : 395 - 403
  • [47] Dose delivered to the patient by megavoltage cone beam computed tomography imaging
    Isambert, A.
    Ferreira, I. H.
    Bossi, A.
    Beaudre, A.
    Nicula, L. E.
    Lefkopoulos, D.
    CANCER RADIOTHERAPIE, 2009, 13 (05): : 358 - 364
  • [48] THE DETAILED EVALUATION OF SUPERNUMERARY TEETH WITH THE AID OF CONE BEAM COMPUTED TOMOGRAPHY
    Tumen, E. C.
    Yavuz, I.
    Tumen, D. S.
    Hamamci, N.
    Berber, G.
    Atakul, F.
    Uysal, E.
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2010, 24 (02) : 1886 - 1892
  • [49] Optimising image quality in intravenous cerebral cone beam computed tomography
    Broadley, Lisa
    Erskine, Brendan
    Marshall, Elissa
    Ewert, Kyle
    Picker, Bjoern
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2024, 71 (01) : 26 - 34
  • [50] Mathematical estimation and in vivo dose measurement for cone-beam computed tomography on prostate cancer patients
    Jeng, Shiu-Chen
    Tsai, Chiao-Ling
    Chan, Wen-Tung
    Tung, Chuan-Jong
    Wu, Jian-Kuen
    Cheng, Jason Chia-Hsien
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 (01) : 57 - 61