Evaluation of proton therapy dose in breast cancer with boron agent based on GATE Monte Carlo code

被引:0
作者
Bijarpasi, Fereshteh Mollaee [1 ]
Sadremomtaz, Alireza [1 ]
机构
[1] Univ Guilan, Fac Sci, Dept Phys, POB 41635-1914, Rasht, Iran
关键词
Proton therapy; Proton boron capture therapy; Boron agent; GATE code; Dose actor; Bragg peak; SIMULATION;
D O I
10.1016/j.jrras.2025.101311
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Proton Boron Capture Therapy (PBCT) has been introduced as a proposed method of increasing the proton therapy dose. The interaction mechanism of this reaction is p + 11B -> 3 alpha. This research was carried out to evaluate the dose of proton beams with boron agents. Methods: All the simulations were done with Monte Carlo GATE code. First, the proton beam and the breast phantom were simulated, and then different boron concentrations were created in the tumor area. Finally, using the dose actor, the amount of the deposited dose, the deposited energy, and the dose of secondary alpha particles in the tumor area were calculated. Results: The simulation results show that at a concentration of 65 ppm of 11B, the dose changes are less than 1% compared to the tumor area without boron, and the depth of the Bragg peak remains unchanged. By increasing the concentration of boron in the tumor area, the deposited dose and the depth of the Bragg peak decrease. In pure 11B, the deposited dose is reduced to half of the original amount. Conclusion: By placing different concentrations of boron agents, the physical aspects and simulation results did not show that boron is effective in increasing the dose in proton therapy. Therefore, 11B cannot be used as a doseenhancing agent in proton therapy.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code
    Guan, Fada
    Peeler, Christopher
    Bronk, Lawrence
    Geng, Changran
    Taleei, Reza
    Randeniya, Sharmalee
    Ge, Shuaiping
    Mirkovic, Dragan
    Grosshans, David
    Mohan, Radhe
    Titt, Uwe
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6234 - 6247
  • [22] Optimization of GATE and PHITS Monte Carlo code parameters for uniform scanning proton beam based on simulation with FLUKA general-purpose code
    Kurosu, Keita
    Takashina, Masaaki
    Koizumi, Masahiko
    Das, Indra J.
    Moskvin, Vadim P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 336 : 45 - 54
  • [23] Optimization of GATE and PHITS Monte Carlo Code Parameters for Uniform Scanning Proton Beam Based On Simulation with FLUKA General-Purpose Code
    Kurosu, K.
    Takashina, M.
    Koizumi, M.
    Das, I.
    Moskvin, V.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 282 - +
  • [24] Effects of Hounsfield number conversion on CT based proton Monte Carlo dose calculations
    Jiang, Hongyu
    Seco, Joao
    Paganetti, Harald
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1439 - 1449
  • [25] Millisecond speed deep learning based proton dose calculation with Monte Carlo accuracy
    Pastor-Serrano, Oscar
    Perko, Zoltan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (10)
  • [26] Patient-specific skin dose evaluation in breast cancer radiotherapy: A Monte Carlo study
    Atarod, Maryam
    Shami, Nahid
    Pourmoghaddas, Amir
    Saeb, Mohsen
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2025, 231
  • [27] Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy
    Yepes, Pablo
    Adair, Antony
    Grosshans, David
    Mirkovic, Dragan
    Poenisch, Falk
    Titt, Uwe
    Wang, Qianxia
    Mohan, Radhe
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (04)
  • [28] RayStation/GATE Monte Carlo simulation framework for verification of proton therapy based on the 12N imaging
    Ahmadi Ganjeh, Zahra
    Zapien-Campos, Brian
    Traneus, Erik
    Both, Stefan
    Dendooven, Peter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (19)
  • [29] FRoG dose computation meets Monte Carlo accuracy for proton therapy dose calculation in lung
    Magro, Giuseppe
    Mein, Stewart
    Kopp, Benedikt
    Mastella, Edoardo
    Pella, Andrea
    Ciocca, Mario
    Mairani, Andrea
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 66 - 74
  • [30] Validation of a GPU-based Monte Carlo code (gPMC) for proton radiation therapy: clinical cases study
    Giantsoudi, Drosoula
    Schuemann, Jan
    Jia, Xun
    Dowdell, Stephen
    Jiang, Steve
    Paganetti, Harald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (06) : 2257 - 2269