A non-enzymatic highly stable electrochemical sensing platform based on allylamine capped copper nanoparticles for the detection of the soil nitrate content
被引:1
|
作者:
Mukherjee, Bimalendu
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Indian Inst Technol, Sch Nano Sci & Technol, Kharagpur 721302, West Bengal, IndiaIndian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Mukherjee, Bimalendu
[1
,2
]
Mandal, Mukti
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, IndiaIndian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Mandal, Mukti
[1
]
Suresh, Raghavv Raghavender
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, IndiaIndian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Suresh, Raghavv Raghavender
[1
]
Kar, Shantanu
论文数: 0引用数: 0
h-index: 0
机构:
Coromandel Int Ltd, Coromandel House, Secunderabad 500003, Telangana, IndiaIndian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Kar, Shantanu
[4
]
Parida, Binaya Kumar
论文数: 0引用数: 0
h-index: 0
机构:
Coromandel Int Ltd, Coromandel House, Secunderabad 500003, Telangana, IndiaIndian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Parida, Binaya Kumar
[4
]
Chakraborty, Somsubhra
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Agr & Food Engn Dept, Kharagpur 721302, West Bengal, IndiaIndian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Chakraborty, Somsubhra
[3
]
Dutta, Gorachand
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, IndiaIndian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
Dutta, Gorachand
[1
]
机构:
[1] Indian Inst Technol, Sch Med Sci & Technol, Nanobiosensors & Biodevices Lab, Kharagpur 721302, West Bengal, India
[2] Indian Inst Technol, Sch Nano Sci & Technol, Kharagpur 721302, West Bengal, India
[3] Indian Inst Technol, Agr & Food Engn Dept, Kharagpur 721302, West Bengal, India
[4] Coromandel Int Ltd, Coromandel House, Secunderabad 500003, Telangana, India
Nitrate (NO3-) ion contamination of water is a major issue that affects many parts of the world due to excessive usage of nitrogen containing fertilizers in the soil. Hence, quantification of NO3- ions in the soil is of utmost importance. In the present research work, we have developed an efficient and highly stable non-enzymatic electrochemical sensor for NO3- ion detection based on allylamine capped copper nanoparticles (Alym@CuNPs) decorated on exfoliated multi-walled carbon nanotubes (Exf-CNTs). Herein, we have addressed the sensor surface storage stability issue of copper nanoparticle based electrochemical sensors for the first time and confirmed the superior storage stability of the Alym@CuNPs modified glassy carbon electrode (GCE) over uncapped copper nanoparticles (uCuNPs) and electrodeposited copper nanoparticles (eCuNPs) modified GCEs. In comparison to the bare GCE, Exf-CNT/GCE and Alym@CuNPs/Exf-CNT/GCE, the proposed Alym@CuNPs-Nafion (NF)/Exf-CNT/GCE demonstrated enhanced catalytic activity towards the electro-reduction of NO3- ions (pH = 2) under optimal experimental conditions, with a considerable increase in cathodic peak currents. Along with that, no inert gas was purged into the electrolyte medium prior to the detection of NO3- ions which makes the sensor more reliable under real environmental conditions. The sensor displayed broad linear ranges from 10 to 1000 mu M (R2 = 0.997), with a limit of detection (LOD) of 5.28 mu M (n = 3) for NO3- ion detection. The sensor surface shows excellent storage stability even up to 45 days with 97.8% retention in current value which is much higher compared to the previously reported works. Additionally, the sensor surface shows promising reproducibility and repeatability results with RSD values of 1.78% and 0.91%, respectively. Moreover, the proposed sensor is successfully utilized to detect NO3- ions in real soil samples.
机构:
Sichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R ChinaSichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R China
Cheng, Xia
Xu, Caili
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R ChinaSichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R China
Xu, Caili
Chen, Qian
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R ChinaSichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R China
Chen, Qian
Wang, Yi
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R ChinaSichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R China
Wang, Yi
Zhang, Yun
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R ChinaSichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R China
Zhang, Yun
Fan, Guangyin
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R ChinaSichuan Normal Univ, Coll Chem & Mat Sci, Chengdu 610068, Sichuan, Peoples R China