Biomechanical Evaluation of a Novel Ceramic Implant for Canine Cranial Cruciate Ligament Rupture Treatment: A Finite Element Analysis Approach

被引:0
作者
Lang, Mark Leon [1 ]
Luepke, Matthias [2 ]
Goetz, Maximilian [1 ]
Volk, Holger A. [1 ]
Klasen, Jan [3 ]
Harms, Oliver [1 ,3 ,4 ]
机构
[1] Univ Vet Med Hannover, Small Anim Med Clin, D-30559 Hannover, Germany
[2] Univ Vet Med Hannover, Dept Gen Radiol & Med Phys, D-30173 Hannover, Germany
[3] Small Anim Clin Germersheim, D-76726 Germersheim, Germany
[4] Specialist Ctr Small Anim Med, Langenhagen, Germany
关键词
ceramic implant; tibial tuberosity advancement; finite element analysis; cranial cruciate ligament rupture; biomechanics; canine orthopaedics; TIBIAL TUBEROSITY ADVANCEMENT; PLATEAU LEVELING OSTEOTOMY; FEMOROTIBIAL CONTACT MECHANICS; ULTRASONOGRAPHIC EVALUATION; RADIOGRAPHIC EVALUATION; LABRADOR RETRIEVERS; DOGS; STIFLE; DISEASE; JOINT;
D O I
10.3390/ani14223296
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
This research investigates the biomechanical effects of a novel ceramic implant for the treatment of canine cranial cruciate ligament rupture (CCLR) based on the tibial tuberosity advancement (TTA) method using finite element analysis (FEA). A 3D FEA of the tibiofemoral joint simulating the applied forces (44.5% of body weight) during the mid-stance phase (joint angle 135 degrees) of the dog's stride was performed. Three conditions were considered for each joint: the physiological condition, the pathological condition with CCLR and the restored condition after TTA. Eight cadavers were used to create fifteen paired knee joints. The results showed significant differences in the forces that could be measured in the patellar tendon (PT) and in the cranial displacement of the tibial tuberosity between the conditions. The PT forces increased in the pathological state and continued to increase in the restored state, while the cranial displacement of the tibial tuberosity increased in the pathological state and decreased again in the restored state. Correlation analyses revealed significant correlations between PT forces, body weight and cranial displacement. The FEA provides initial insights into the force distribution and functionality of the ceramic implant. However, further testing is required to validate reliability and evaluate the efficacy of the implant.
引用
收藏
页数:15
相关论文
共 50 条
[31]   Biomechanical evaluation of the effect of varying humeral implant length in total elbow replacement: a finite element analysis [J].
Low, Jomain ;
Pareatumbee, Pivatidevi ;
Yew, Andy ;
Tay, Kenny ;
Sen Howe, Tet ;
Thoreson, Andrew ;
An, Kai-Nan ;
Morrey, Bernard F. ;
Koh, Joyce Suang Bee .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (07) :1783-1791
[32]   Biomechanical assessment of a novel L4/5 level interspinous implant using three dimensional finite element analysis [J].
Song, C. ;
Li, X. -F. ;
Liu, Z. -D. ;
Zhong, G. -B. .
EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2014, 18 (01) :86-94
[33]   Outcome after Modified Maquet Procedure in dogs with unilateral cranial cruciate ligament rupture: Evaluation of recovery limb function by use of force plate gait analysis [J].
Della Valle, Giovanni ;
Caterino, Chiara ;
Aragosa, Federica ;
Micieli, Fabiana ;
Costanza, Dario ;
Di Palma, Cristina ;
Piscitelli, Alfonso ;
Fatone, Gerardo .
PLOS ONE, 2021, 16 (08)
[34]   Original Biomechanical analysis of a novel bone cement bridging screw system for the treatment of Kummell disease: a finite element analysis [J].
Wang, Biao ;
Zhan, Yi ;
Bai, Yesheng ;
Kong, Lingbo ;
Li, Liang ;
Zhang, Haiping ;
He, Simin ;
Hao, Dingjun .
AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (10) :7052-7062
[35]   Biomechanical Evaluation of Platform Switching in Different Implant Protocols: Computed Tomography-Based Three-Dimensional Finite Element Analysis [J].
Pessoa, Roberto S. ;
Vaz, Luis Geraldo ;
Marcantonio, Elcio, Jr. ;
Vander Sloten, Jos ;
Duyck, Joke ;
Jaecques, Siegfried V. N. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (05) :911-919
[36]   Biomechanical Evaluation of the Effects of Implant Neck Wall Thickness and Abutment Screw Size: A 3D Nonlinear Finite Element Analysis [J].
Jeng, Ming-Dih ;
Lin, Yang-Sung ;
Lin, Chun-Li .
APPLIED SCIENCES-BASEL, 2020, 10 (10)
[37]   A novel approach for optimal graft positioning and tensioning in anterior cruciate ligament reconstructive surgery based on the finite element modeling technique [J].
Naghibi, Hamid ;
Janssen, Dennis ;
Van Tienen, Tony ;
Van de Groes, Sebastiaan ;
Van de Boogaard, Ton ;
Verdonschot, Nico .
KNEE, 2020, 27 (02) :384-396
[38]   Biomechanical analysis of three different types of fixators for anterior cruciate ligament reconstruction via finite element method: a patient-specific study [J].
Zainal Abidin, Nur Afikah ;
Abdul Wahab, Abdul Hadi ;
Abdul Rahim, Rabiatul Adibah ;
Abdul Kadir, Mohammed Rafiq ;
Ramlee, Muhammad Hanif .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (09) :1945-1960
[39]   Biomechanical effects of cross-pin's diameter in reconstruction of anterior cruciate ligament - A specific case study via finite element analysis [J].
Abidin, Nur Afikah Zainal ;
Ramlee, Muhammad Hanif ;
Ab Rashid, Amir Mustakim ;
Ng, Bing Wui ;
Gan, Hong Seng ;
Kadir, Mohammed Rafiq Abdul .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (07) :2424-2436
[40]   Biomechanical analysis of three different types of fixators for anterior cruciate ligament reconstruction via finite element method: a patient-specific study [J].
Nur Afikah Zainal Abidin ;
Abdul Hadi Abdul Wahab ;
Rabiatul Adibah Abdul Rahim ;
Mohammed Rafiq Abdul Kadir ;
Muhammad Hanif Ramlee .
Medical & Biological Engineering & Computing, 2021, 59 :1945-1960